FN256-16-46 Schaffner EMC Inc, FN256-16-46 Datasheet - Page 2

FILTER 3-PHASE NEUTRAL LINE 16A

FN256-16-46

Manufacturer Part Number
FN256-16-46
Description
FILTER 3-PHASE NEUTRAL LINE 16A
Manufacturer
Schaffner EMC Inc
Series
FN 256r
Type
Filterr
Datasheet

Specifications of FN256-16-46

Termination Style
Terminal Block
Filter Type
Power Line
Voltage - Rated
277V, 480V
Current
16A
Mounting Type
Chassis Mount
Voltage Rating
277 VAC
Current Rating
16 A
Mounting Style
Chassis
Filtered
Yes
Frequency
50 Hz
Leakage Current
3.4 mA
Product
Power Line Filters
Application
For entire systems, install, power supply, medical equipment, high power office equipment, general purpose
Brand/series
FN 256 Series
Current, Leakage
3.4 mA
Current, Rating
16 A
Dimensions
80 H × 115 W × 120 L mm
Frequency, Operating
DC to 60 Hz
Hipot Rating, Line To Ground
2650
Hipot Rating, Line To Line
2100
Inductance
1.14 mH
Ip Rating
IP20
Phase
3
Primary Type
1-Stage, AC, General Purpose
Resistance
0.68 Megaohms
Schaffner Part Number
293-643
Standards
UL Recognized, CSA Certified, IEC Approved
Voltage, Operating
480/277 VAC
Voltage, Range
480 VAC
Voltage, Rating
480 VAC
Wire Size
10 AWG
Hipot Test Voltage
P/N-E 3000 VDC for 2 Sec.; P/N-P 2100 VDC for 2 Sec.
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Inductance
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
293-643
817-1069
FN 256 - 16-46

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FN256-16-46
Manufacturer:
SCHAFFNE
Quantity:
26
Filter selection table
Filter*
FN 256-8-46
FN 256-16-46
FN 256-25-47
FN 256-36-47
FN 256-64-52
FN 256-80-..
FN 256-120-..
FN 256-160-..
*
**
*** Filters with -28 connections are rated for 40°C environmental temperature only.
Typical filter attenuation
Per CISPR 17; A = 50Ω/50Ω sym; B = 50Ω/50Ω asym; C = 0.1Ω/100Ω sym; D = 100Ω/0.1Ω sym
8A types
64A types
> Components
To compile a complete part number, please replace the -.. with the required I/O connection style.
Maximum leakage under normal operating conditions, based on the assumption that all three phases and the neutral conductor are connected to the supply and the consumer. In this case, the
current will mainly return through the neutral line, not as earth leakage.
> FN 256
Rated current
@ 50°C (40°C)
120 (131)
160 (175)
16 (17.5)
25 (27)
36 (39)
64 (70)
80 (88)
16A types
80A types
8 (8.8)
[A]
Leakage current**
@ 400VAC/50Hz
[mA]
3.4
3.4
3.4
3.4
3.4
3.4
5.0
6.8
25A types
120A types
@ 25°C/50Hz
Power loss
11.6
14.8
18.4
18.8
25.1
30.7
[W]
2.7
6.0
-46
-46
-47
-47
-52
-28***
-28***
-28***
Input/Output
36A types
160A types
connections
-34
-35
-40
Weight
[kg]
0.8
1.1
1.4
1.5
2.2
4.5
6.1
8.0

Related parts for FN256-16-46