Page 1
GP1UE26XK0VF/GP1UE27XK0VF Series GP1UE28XK0VF/GP1UE28YK0VF Series ■ Features 1. Low operating voltage:2.7 to 5.5V 2. Low dissipation current:MAX. 0.4mA(at Vcc=3V) 3. Compact (case volume). 4. Various B.P.F. (Band-Pass Filter) frequency to meet different user needs. 5. Lead-free and RoHS directive compliant. ■ ...
Page 2
... R2.1 0 OUT 3 0.8 CC 5.4 3 GND 6.8 Example of mounting drawing from solder side (Reference) 2.54 2.54 Top of lenz 1.25 1.4 1 2.9 2.9 *3 5.8 GP1UE28XK0VF GP1UE28YK0VF GP1UE280XKVF GP1UE280YKVF GP1UE281XKVF GP1UE281YKVF GP1UE282XKVF GP1UE282YKVF GP1UE283XKVF GP1UE283YKVF Sheet No.: OP06005 (Unit : mm) 1.4 1.4 Unit kHz ...
Page 3
Internal Block Diagram ■ Absolute Maximum Ratings Parameter Symbol Supply voltage Operating temperature T -10 to +70 opr Storage temperature T -20 to +70 stg *2 Soldering temperature T sol *1 No dew condensation is allowed ...
Page 4
Performance Using the transmitter shown in Fig. 1, the output signal of the light detecting unit is good enough to meet the following items in the standard optical system in Fig Linear reception distance characteristics *5 When ...
Page 5
Precautions for Operation 1. When this infrared remote control detecting unit shall be adopted for wireless remote control, please use the following signal format . (NEC code,RC-6code etc.) n ・Total duty ratio D (Emitting time t Σ t N=1 ...
Page 6
There is a possibility that noise on output may be caused by environmental condition (Disturbing light noise, Electromagnetic noise, Power supply line noise, etc.) even if there is no input transmission signal. 11. Please shall confirm operation or your ...