LTC2934CDC1#PBF Linear Technology, LTC2934CDC1#PBF Datasheet - Page 5

no-image

LTC2934CDC1#PBF

Manufacturer Part Number
LTC2934CDC1#PBF
Description
Manufacturer
Linear Technology
Datasheet

Specifications of LTC2934CDC1#PBF

Voltage Supervisor Type
Voltage Monitor
Number Of Voltage Supervisors
1
Reset Threshold Voltage (min)
AdjV
Reset Threshold Voltage (max)
AdjV
Operating Supply Voltage (min)
1.6V
Operating Supply Voltage (max)
5.5V
Operating Temperature Classification
Commercial
Operating Temp Range
0C to 70C
Pin Count
8
Mounting
Surface Mount
Lead Free Status / RoHS Status
Compliant
PIN FUNCTIONS
TYPICAL PERFORMANCE CHARACTERISTICS
ADJ: Reset Threshold Adjustment Input. Tie to resistive
divider between monitored voltage and GND to confi gure
desired reset threshold. See the Applications Information
section for details. Tie to V
Exposed Pad (DFN Only): Exposed Pad may be left fl oating
or connected to device ground.
GND: Device Ground.
MR: Manual Reset Input. Attach a push-button switch
between this input and ground. A logic low on this input
pulls RST low. When the MR input returns to logic high,
RST returns high after the reset timer has expired. Tie to
V
PFI: Power-Fail Threshold Adjustment Input. Tie to
resistive divider between monitored voltage and GND
to configure desired power-fail threshold. See the
Applications Information section for details. Tie to V
GND if unused.
CC
if unused.
250
200
150
100
50
0
0
Supply Current vs RT
Input Voltage
V
CC
0.5
= 3.6V
CC
1
RT INPUT VOLTAGE (V)
if unused.
1.5
2
2.5
3
3.5
2934 G07
4
CC
or
PFO: Power-Fail Output. PFO pulls low when monitored
voltage falls below the power-fail (PFI) threshold. PFO
is released when the PFI voltage rises above the power-
fail threshold by 2.5%. PFO is available with open-drain
(LTC2934-1) or active pull-up (LTC2934-2) outputs. Leave
open if unused.
RST: Reset Output. RST pulls low when monitored volt-
age falls below the reset threshold. RST is released after
monitored voltage exceeds the reset threshold plus 5%
hysteresis and after reset timer has expired. RST is available
with open-drain (LTC2934-1) or active pull-up (LTC2934-2)
outputs. Leave open if unused.
RT: Reset Timeout Selection Input. Tie to GND or V
desired reset timeout. Tie low for 15ms delay or high for
200ms delay.
V
GND.
CC
: Power Supply Input. Bypass V
5
4
3
2
0
1
0
Supply Current vs MR Input Voltage
0.5
T
A
1
MR INPUT VOLTAGE (V)
= 25°C, unless otherwise noted.
1.5
2
2.5
3
V
CC
= 3.6V
3.5
2934 G08
4
CC
LTC2934
with 0.1μF to
CC
5
2934f
for

Related parts for LTC2934CDC1#PBF