13C5000PS5K Honeywell, 13C5000PS5K Datasheet - Page 3

no-image

13C5000PS5K

Manufacturer Part Number
13C5000PS5K
Description
Industrial Pressure Sensors 15Vdc 500psi Sealed Transducer
Manufacturer
Honeywell
Type
Sealed Gager
Datasheet

Specifications of 13C5000PS5K

Pressure Range
0 to 5000Psi
Overload Pressure (max)
10000Psi
Mounting
Stud
Pin Count
4
Operating Temp Range
-40C to 125C
Operating Temperature Classification
Automotive
Operating Supply Voltage (max)
15V
Operating Pressure
0 psi to 5000 psi
Pressure Type
Gauge
Output Type
Basic
Mounting Style
Stud
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
15 V
Port Size
1/4 in - 18 NPT
Pressure Port
Y
Sensor Type
Transducers
Lead Free Status / RoHS Status
Compliant
Pressure Sensors
Low-cost, Stainless Steel, Isolated Sensors
PERFORMANCE CHARACTERISTICS – UNCOMPENSATED SERIES
Characteristic
Zero pressure offset
Pressure non-linearity
Pressure hysteresis
Repeatability
Temp. coefficient of span
(
Temp. coefficient of resistance
(0 °C to 82 °C [32 °F to 180 °F])
Temp. coefficient of offset
(0 °C to 82 °C [32 °F to 180 °F])
Thermal hysteresis
(0 °C to 82 °C [32 °F to 180 °F])
Long-term stability of offset and span
Response time
Input resistance
Output resistance
PRESSURE RANGE SPECIFICATIONS – UNCOMPENSATED SERIES
Catalog Listing
13U 0500P A 0 K
13U 1000P A 0 K
13U 2000P A 0 K
13U 3000P A 0 K
13U 5000P A 0 K
NOTES
1. Reference conditions (unless otherwise noted): T
2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero
3. Pressure non-linearity is based on best-fit straight line from zero to the full-scale pressure. Pressure hysteresis is the
4. The error band resulting from maximum deviation of a transducer’s output parameter (offset, span, or resistance) as
5. Long-term stability over a six-month period.
6. Response time for a 0 psi to FSS pressure step change, 10 % to 90 % rise time.
7. The maximum pressure that can be applied without changing the transducer’s performance or accuracy.
8. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer
case.
Honeywell • Sensing and Control
0 °C to 82 °C [32 °F to 180 °F])
±0.0015 mA.
pressure. FSS is ratiometric to supply voltage.
maximum output difference at any point within the operating pressure range for increasing and decreasing pressure.
temperature is varied from 25 °C [77 °F] to any other temperature within the specified range 0 °C to 82 °C [32 °F to
180 °F]. This parameter is not 100 % tested and is guaranteed by process design and tested on a sample basis only.
Temperature coefficient of span is evaluated using a constant current source.
(6)
(3)
(3)
(4)
(4)
(4)
(5)
Pressure range
0 psi to 500 psi
0 psi to 1000 psi
0 psi to 2000 psi
0 psi to 3000 psi
0 psi to 5000 psi
Minimum
-7.5
360
2700
4.0
4.0
A
= 25 °C [77 °F]; Supply V
Full scale span
175 mV to 300 mV
175 mV to 300 mV
175 mV to 300 mV
175 mV to 300 mV
290 mV to 500 mV
Typical
0
±0.1
±0.015
±0.010
720
3420
30
±0.1
±0.1
0.1
4.75
4.75
(2)
S
= 10 Vdc ±0.01 Vdc or I
(1)
Proof pressure
1200 psi
3000 psi
6000 psi
9000 psi
10,000 psi
Maximum
+7.5
±0.25
±0.030
±0.030
1260
4500
±0.3
±0.3
6.0
6.0
13 mm Series
(7)
S
Burst pressure
2400 psi
5000 psi
10,000 psi
10,000 psi
10,000 psi
= 1.5 mA
%FSS
%FSS
%FSS
Unit
mV/V
%FSS
%FSS
ppm/°C
ppm/°C
µV/V/°C
ms
kΩ
kΩ
3
(8)