TL-Q5MC1-R Omron, TL-Q5MC1-R Datasheet

no-image

TL-Q5MC1-R

Manufacturer Part Number
TL-Q5MC1-R
Description
Proximity Sensors Proximity Sensor
Manufacturer
Omron
Series
TL-Qr
Datasheets

Specifications of TL-Q5MC1-R

Proximity Sensor Sensing Distance
5mm
Proximity Sensor Sensing Distance Range
2 to 7mm
Proximity Sensor Switching Mode
NO
Mounting
Panel
Operating Temp Range
-25C to 70C
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
10V
Operating Supply Voltage (typ)
12/15/18/24V
Operating Supply Voltage (max)
30V
Pin Count
2
Output Type
NPN
Maximum Operating Temperature
+ 70 C
Operating Supply Voltage
10 V to 30 V
Sensing Distance
5 mm
Minimum Operating Temperature
- 25 C
Features
NO
Sensor Type
Inductive
Sensing Object
Metallic
Response Frequency
500Hz
Material - Body
ABS Resin
Shielding
Unshielded
Voltage - Supply
10 V ~ 30 V
Terminal Type
3-Wire
Package / Case
Box
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TL-Q5MC1-R 2M
Manufacturer:
OMRON
Quantity:
500
A Wealth of Models for All Types of
Applications
■ Easy installation, high-speed pulse generator, high-speed
■ Direct mounted to metal (-N Models).
■ A wealth of models ideal for limit control, counting control,
Ordering Information
Sensors
DC 2-Wire Models
Note: Models with a different frequency are available to prevent mutual interference. The model numbers are TL-N@MD@5 and TL-Q5MD@5 (e.g., TL-N7MD15).
DC 3-Wire and AC 2-Wire Models
Note: Models with a different frequency are available to prevent mutual interference. Models numbers for Sensors with different frequencies are TL-@@M@@5
*1. Models are also available with 5-m cables. Add the cable length to the model number (example: TL-N5ME1 5M).
*2. Models with robotics cables are also available. Add -R to the end of the model number (example: TL-N5ME1-R).
Unshielded
Unshielded
Rectangular Standard Proximity Sensor
TL-N/TL-Q/TL-G
rotation control, and more.
and other applications (-N Models).
(example: TL-N5ME15).
Be sure to read Safety Precautions on
page 9.
Appearance
Appearance
Grooved
30 × 30
17 × 17
25 × 25
40 × 40
17 × 17
25 × 25
30 × 30
40 × 40
http://www.ia.omron.com/
8 × 9
2 mm
Sensing distance
Sensing distance
5 mm
5 mm
5 mm
7 mm
7.5 mm
10 mm
12 mm
20 mm
20 mm
TL-Q5MD1
TL-N7MD1
TL-N12MD1
TL-N20MD1
Output configuration
DC 3-wire, NPN
DC 3-wire, NPN
AC 2-wire
DC 3-wire, NPN
AC 2-wire
DC 3-wire, NPN
AC 2-wire
DC 3-wire, NPN
NO
Operation mode
Model
TL-Q5MD2
TL-N7MD2
TL-N12MD2
TL-N20MD2
TL-Q2MC1
TL-Q5MC1
TL-N5ME1
TL-N5MY1
TL-N10ME1
TL-N10MY1
TL-N20ME1
TL-N20MY1
TL-G3D-3
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
NC
NO
*1
*2
*2
*1
*2
*1
*2
Operation mode
Model
TL-Q5MC2
TL-N5ME2
TL-N5MY2
TL-N10ME2
TL-N10MY2
TL-N20ME2
TL-N20MY2
NC
*1
*1
(excluding TL-G)
1

Related parts for TL-Q5MC1-R

TL-Q5MC1-R Summary of contents

Page 1

... Grooved 7.5 mm Note: Models with a different frequency are available to prevent mutual interference. Models numbers for Sensors with different frequencies are TL-@@M@@5 (example: TL-N5ME15). *1. Models are also available with 5-m cables. Add the cable length to the model number (example: TL-N5ME1 5M). ...

Page 2

... Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. http://www.ia.omron.com/ Applicable Sensors Provided with these Sensors TL-N5ME@, TL-N7MD@ TL-N5MY@ TL-N10ME@, TL-N12MD@ TL-N10MY@ TL-N20ME@, TL-N20MD@ TL-N20MY@ --- TL-N5ME@, TL-N5MY@ --- TL-N10ME@, TL-N10MY@ TL-N7MD@ TL-N12MD 9.6 mm Iron ...

Page 3

... Destruction: 200 m/s 10 times each and Z directions IEC IP67 Approx (c)Copyright OMRON Corporation 2007 All Rights Reserved. TL-N/TL-Q/TL-G TL-G3D-3 7.5±0.5mm 10 mm Iron, 10 × 5 × 0.5mm 1 ms max VDC, ripple (p-p): 5% max max VDC (no-load) NPN transistor output 20 mA max. ...

Page 4

... E Models (DC switching models): A full-wave rectification power supply of 24 VDC 10% (average value) can be used. http://www.ia.omron.com/ TL-N10ME@, TL-N10MY 10 Iron times each and Z directions Approx. 170 g (c)Copyright OMRON Corporation 2007 All Rights Reserved. TL-N/TL-Q/TL-G TL-N20ME@, TL-N20MY 10 Iron Models Models Approx. 240 g 4 ...

Page 5

... Distance Y (mm) Sensing Head TL-N@MD@ TL-N20MD TL-N12MD@ 10 TL-N7MD -25 -20 -15 - TL-N7MD@ Sensing Head Distance Y (mm) TL-N12MD@ Sensing Head TL-N20MD@ Sensing Head Residual Output Voltage TL-N@ 100 300 500 1,000 Load current (mA) http://www.ia.omron.com/ TL-Q5M −8 −6 −4 −2 ...

Page 6

... Side length of sensing object: d (mm) TL-N12MD × Iron 10 8 Stainless steel (SUS304) 6 Brass Copper 4 Aluminum Side length of sensing object: d (mm) (c)Copyright OMRON Corporation 2007 All Rights Reserved. TL-N/TL-Q/TL-G TL-G3D 0 × Operate Reset Side length of sensing object: d (mm) TL-N5@ d × Iron 4 3 ...

Page 7

... Side length of sensing object: d (mm) I/O Circuit Diagrams DC 2-Wire Models Operation Model mode Non-sensing area Sensing object TL-Q5MD1 TL-N7MD1 (%) NO TL-N12MD1 TL-N20MD1 Non-sensing area Sensing object TL-Q5MD2 (%) TL-N7MD2 NC TL-N12MD2 TL-N20MD2 http://www.ia.omron.com/ TL-N20@ d × Iron Stainless steel (SUS304 Brass 6 Aluminum Side length of sensing object: d (mm) ...

Page 8

... TL-N10MY2 Load TL-N20MY2 Operation indicator (red) http://www.ia.omron.com/ Timing chart Present Not present ON OFF ON OFF Proximity Present Not present ON * Load current: 100 mA max., TL-Q2MC1 Load current max., TL-Q5MC1 OFF ON OFF Present Not present Operate Reset High Low ON Proximity Sensor OFF Present ...

Page 9

... Safety Precautions Refer to Warranty and Limitations of Liability. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Do not short-circuit the load, otherwise the Sensor may be damaged. Do not supply power to the Sensor with no load, otherwise the Sensor may be damaged ...

Page 10

... Designing the Sensing Object for TL-G3D-3 Grooved Model For high-speed response to a toothed metal plate, the sensing objects must be at least the size of the standard sensing object and there must be sufficient distance between sensing objects. The response frequency for a toothed wheel like the one shown at the right is 1 kHz min ...

Page 11

... Standard length http://www.ia.omron.com/ 21 1.5 9.3 0.5 * 18.1 0.5 3± 0.3 Toothed washer Lock nut M8 × 0.75 (slightly thin 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm Insulator diameter: 1.2 mm), 29.8 Standard length Two, 4.3 dia Indicator *2 6 23.8 ...

Page 12

... Two 4 16± 0.2 22± 0.2 7 2.3 14.5 Applicable Models: TL-N10ME@ *2 Applicable Models: TL-N10MY@ Applicable Models: TL-N12MD@ *2 Y92E-N10C15 30 22± 0.3 Two, 4.3 dia. 13± 0.2 21 2.3 3.5 5.5 24.3 2.3 C15 conduit screw, JIS-B-0204 Applicable Models: TL-N10ME@ Applicable Models: TL-N10MY@ Applicable Models: TL-N12MD@ (c)Copyright OMRON Corporation 2007 All Rights Reserved ...

Page 13

... Be sure that the power supply polarity and oth- er wiring is correct. Incorrect wiring may cause explosion or burning. Connection without a Load If the power supply is connected directly with- out a load, the internal elements may explode or burn. Be sure to insert a load when connect- ing the power supply. ...

Page 14

... Conduits, ducts, pre-wired, terminal wiring, ease of main- tenance and inspection mT* max. Do not use the Sensor at a level higher than 20 mT. Life: Power-ON time/frequency of use (c)Copyright OMRON Corporation 2007 All Rights Reserved. Peripheral metal Sensing distance Material, distance Fluctuation in tran- to Sensor, orien- sit point, allowable tation, etc ...

Page 15

... Sensing Object Material The sensing distance varies greatly depending on the material of the sensing object. Study the engineering data for the influence of sensing object material and size and select a distance with sufficient leeway. • In general, if the Example: E2-X10D@ sensing object is a non- ...

Page 16

... OFF It is recommend that leeway be included in the actual values used. For 12 VDC, use 15 kΩ or less and 450 mW or higher, and for 24 VDC, use 30 kΩ or less and 0 higher. (c)Copyright OMRON Corporation 2007 All Rights Reserved. AC power supply voltage Vs 2 (mW) ...

Page 17

... Loads with Large Inrush Current Loads, such as lamps or motors, that cause a large inrush weaken or damage the switching element. In this situation, use a relay. * E2K, TL-N@ higher ●Mounting Mounting the Sensor When mounting a Sensor, do not tap it with a hammer or otherwise subject it to excessive shock. This will weaken water resistance and may damage the Sensor ...

Page 18

... A parallel connection can be used if A and B will not be operated simulta- neously and there is no need to hold the load. The leakage current, however, Load will be n times the value for each Sensor and reset failures will frequently oc- cur. ("n" is the number of Proximity Sensors and B will be operated simultaneously and the load is held, a parallel con- nection is not possible ...

Page 19

... The residual voltage of the E2E-XD-M1J 3-Wire Sensors Operation can be reversed with the signal input switch on the S3D2. (c)Copyright OMRON Corporation 2007 All Rights Reserved. Description Example: A maximum of two Sensors can be used when an MY (24-VDC) Relay is used for the load ...

Page 20

... Disassembly and Repair Do not under any circumstances attempt to disassemble or repair the product. Quick Failure Check You can conveniently check for failures by connecting the E39-VA Handy Checker to check the operation of the Sensor. http://www.ia.omron.com/ Proximity Sensors Technical Guide (c)Copyright OMRON Corporation 2007 All Rights Reserved. ...

Page 21

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords