TLW3MB1 Omron, TLW3MB1 Datasheet - Page 2

TLW3MB1

Manufacturer Part Number
TLW3MB1
Description
Manufacturer
Omron
Datasheet

Specifications of TLW3MB1

Proximity Sensor Type
Inductive
Proximity Sensor Sensing Distance
3mm
Proximity Sensor Sensing Distance Range
2 to 7mm
Proximity Sensor Switching Mode
NO
Mounting
Panel
Operating Temp Range
-25C to 70C
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
10V
Operating Supply Voltage (typ)
12/15/18/24V
Operating Supply Voltage (max)
30V
Pin Count
3
Output Type
PNP
Lead Free Status / RoHS Status
Compliant
Ratings and Specifications
DC 2-Wire Models
*1. The response frequency is an average value.
*2. For environments that require oil resistance, the upper limit of the ambient operating temperature range is 40°C.
Item
Sensing distance
Set distance
Differential travel
Detectable object
Standard sensing object
Response frequency *1
Power supply voltage
(operating voltage range)
Leakage current
Con-
trol
output
Indicators
Operation mode (with sensing
object approaching)
Protection circuits
Ambient temperature range
Ambient humidity range
Temperature influence
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (packed state)
Materials
Accessories
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
Load current
Residual voltage
Case
Sensing surface
Model
5 mm ±10%
0 to 4 mm
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page
5.)
Iron, 18 × 18 × 1 mm
500 Hz
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
0.8 mA max.
3 to 100 mA
3.3 V max. (under load current of 100 mA with cable length of 2 m)
D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
D1 Models: NO
D2 Models: NC
Load short-circuit protection, Surge suppressor
Operating/Storage: −25 to 70°C (with no icing or condensation) *2
Operating/Storage: 35% to 95% (with no condensation)
±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC for 1 min between current-carrying parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s
IEC 60529 IP67, in-house standards: oil-resistant *2
Pre-wired Models (Standard cable length: 2 m)
Approx. 45 g
Heat-resistant ABS
Instruction manual
Refer to the timing charts under I/O Circuit Diagrams on page 6 for details.
2
3 times each in X, Y, and Z directions
TL-W5MD@
TL-W
2

Related parts for TLW3MB1