TL-W5E1 10M Omron, TL-W5E1 10M Datasheet
TL-W5E1 10M
Specifications of TL-W5E1 10M
Related parts for TL-W5E1 10M
TL-W5E1 10M Summary of contents
Page 1
... Unshielded Shielded 5 mm *1. Models with a different frequency are also available to prevent mutual interference. The model numbers are TL-W@M@@5 (e.g., TL-W5MD15). *2. Models with robotics cables are also available. The model numbers are TL-W@MC1-R (e.g., TL-W1R5MC1-R). Model Operation mode NO NC TL-W5MD1 2M *1 TL-W5MD2 2M *1 ...
Page 2
... Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. *2. For environments that require oil resistance, the upper limit of the ambient operating temperature range is 40°C. TL-W5MD@ Refer to the timing charts under I/O Circuit Diagrams on page 6 for details times each and Z directions TL-W 2 ...
Page 3
... X, Y, and Z directions * Approx Instruction manual TL-W TL-W5E1, TL-W5E2 TL-W20ME1 TL-W5F1, TL-W5F2 TL-W20ME2 20 mm ±10 15% of sensing distance Iron, 50 × 50 × 300 Hz min min VDC ( VDC ( VDC VDC), ripple ripple (p-p): 20% max ...
Page 4
... Sensing head TL-W5E/-W5F −10 −8 −6 −4 − Distance Y (mm) Sensing head TL-W3MC1 −6 −4 − Distance Y (mm) Sensing head TL-W20 −20 −15 −10 − Distance Y (mm) Sensing head TL-W TL-W5MC1/-W5MD −8 −6 −4 − Distance Y (mm) Sensing head 4 ...
Page 5
... Iron Stainless steel (SUS304) 2 Brass Aluminum Copper Side length of sensing object: d (mm) TL-W20 × Iron Stainless steel (SUS304 Brass 6 Aluminum Side length of sensing object: d (mm) TL-W TL-W5MC1 7 d × Iron Stainless steel 4 (SUS304) 3 Brass Aluminum 2 Copper Side length of sensing object: d (mm) 5 ...
Page 6
... NO TL-W5MD1 Sensing object (%) NC TL-W5MD2 DC 3-Wire Models Operation mode Model TL-W1R5MC1 NO TL-W3MC1 TL-W5MC1 TL-W3MC2 NC TL-W5MC2 TL-W5E1 NO TL-W20ME1 TL-W5E2 NC TL-W20ME2 NO TL-W5F1 NC TL-W5F2 Timing chart Set position Unstable Stable sensing sensing area area Proximity Sensor 100 80 (TYP) 0 Rated ON sensing distance Setting indicator (green) ...
Page 7
... TL-W5MD@ TL-W5MC1@ TL-W20ME@ n TL-W5E@/-W5F@ l Proximity Note: Values in parentheses apply to Sensors operating at different Sensor frequencies. ● Mounting • Use M3 flat-head screws to mount the TL-W1R5MC1 and TL- W3MC1 • Do not exceed the torque in the following table when tightening the 8 resin cover screws Model 20 ...
Page 8
... Indicator *2 10 *1. TL-W5MC1 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm Insulator diameter: 1.2 mm), Standard length TL-W5MD@ 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm Insulation diameter: 1.3 mm), Standard length *2. C Models: Detection indicator (red) ...