2CPSA1A3
Actual product appearance may vary.
Supporting Documentation
Description
The 2CPS Cable Pull Safety Switch provides readily accessible emergency stop
over a long, linear distance. It is a cost - effective means of providing this emergency
stop signal compared to multiple emergency stop push buttons. (Cable Pull Safety
Switches are not, however, to be used as a means of personnel safeguarding.
They may be used to prevent further injury or damage to equipment when used for
emergency stop signaling.)
The 2CPS Series Cable Pull Safety Switch is designed to provide emergency stop
protection for exposed conveyor lines. The internal mechanism latches on both
slackened cable (push) and pulled cable. This capability enhances productivity by
eliminating nuisance stops due to variations in temperature, stretch of cable over
time, and other application variables.
A line in the midpoint of the cable tension window indicates proper cable tension,
providing easy and intuitive set-up. The direct acting switch contacts are held
closed when the actuating cable is under proper tension and the reset knob is set
to RUN. When the actuating cable is pulled, slackened or broken, a cam positively
opens the NC (Normally Closed) switch contacts. The snap action, trip operation
causes the switch contacts to change state and mechanically latch almost
simultaneously when the cable is pulled, slackened or broken. The NC switch
contacts remain open until the 2CPS is reset by properly tensioning the cable and
manually rotating the reset knob.
When the direct acting switch contacts open, the auxiliary contacts also actuate
(open contacts close and closed contacts open). The auxiliary contacts are
electrically isolated from the direct acting switch contacts. These NO (Normally
Open) contacts may be used for monitoring or signaling.
The 2CPS complies with: Low Voltage Directive 73/23/EEC, as amended by
directive 93/68/EEC; Machinery Directive 98/37/EEC only as the directives relate to
the components being used in a safety function; IEC/EN60947 -1; IEC/EN60947 - 5-1;
IEC/EN60947 - 5-5.
Features
Positive opening operation of normally
closed contacts
Choice of 2NC/2NO or 3NC/1NO contact
configurations
Maximum cable length in a single
direction is 76 m (250 ft) for a combined
length of 152 m (500 ft) in dual
directions
Choice of three actuator configurations
Removable contact block version
available
Large wiring cavity with straight -
through wiring
24 Vdc or 120 Vac bright, multi - cluster
LED status indicator light available
Gold-plated contacts are standard
Die-cast zinc housing
Optional hardware packs available
Product Type
Actuator
Switch Type
Contact Material
Termination Type
Ampere Rating
Voltage
Housing Material
Series Name
Shock
Vibration
Sealing
Approvals
CSA File #
UL File #
Agency Approvals and Standards
Mechanical Life
Operating Temperature Range
Availability
UNSPSC Code
UNSPSC Commodity
Contact Block
Indicator
Note 1
Mounting
Dimensions
Accessories
Engineering
Drawing
Site Map
Product Specifications
Installation
Instructions
Contact Block
Options
?
?
?
?
?
2CPS Series, Cable Pull Safety Switch,
Cable, Maintained Right Side, No
Actuation Left Side, 2NC/2NO Direct
Opening (Switch 2, Left: 1NC/1NO;
Switch 2, Right: 1NC/1NO), 1/2 NPT,
Gold-plated Contacts
Potential Applications
Long conveyor systems found in
warehouses and distribution centers
Conveyor systems having a high
amount of vibration
Conveyor systems that experience
wide temperature swings
Long conveyor systems where easy
through wiring, or highly visible trip
status is required
Perimeter guarding where hosedown
conditions are present
Cable Pull Safety Switch
Cable, Maintained Right Side, No
Actuation Left Side
2NC/2NO Direct Opening (Switch 1,
Left: 1NC/1NO; Switch 2, Right:
1NC/1NO)
Gold - plated
1/2 NPT
10 uA to 50 mA Low Energy
250 Vac and 60 Vdc Maximum
Zinc Die - Cast
2CPS
15 G
10 Hz - 500 Hz, 5 G
IP67, NEMA/UL 1, 4, 12, 13
UL, CSA, CE
LR57326
E37138, E157416
EN60947 - 1, EN - 60947 - 5 - 1,
EN60947 - 5 - 5
1 Million
- 40 °C to 85 °C [
Global
302119
302119 Switches and controls and
relays
Mounted to Housing
None
Low Voltage Directive 73/23/EEC,
as amended by directive
93/68/EEC. Machinery Directive
98/37/EEC only as the directives
relate to the components being
used in a safety function.
Contact
Configurations
Application
Drawing
- 40 °F to 185 °F]
My Links
Keyword Search
Product Search
Search for product and
support information.
Part number search:
Use (*) to expand search
All Sensing and Control
Login to iCOM
Login as Rep/AD
Login as Guest
Login to Digital
University
Specification Search

Related parts for 2CPSA1A3

Related keywords