SR1500ALSASRNA Intel (CPU), SR1500ALSASRNA Datasheet - Page 20

no-image

SR1500ALSASRNA

Manufacturer Part Number
SR1500ALSASRNA
Description
Manufacturer
Intel (CPU)
Datasheet

Specifications of SR1500ALSASRNA

Lead Free Status / RoHS Status
Not Compliant
Monthly Specification Update
Implication
Status
Workaround
Problem
Implication
Status
Workaround
Problem
Implication
Status
18
Problem
22.
23.
24.
microcode in BIOS.
reset multiple times before completing POST.
files with correct extension.
Checkup7.exe (microcode update utility) is not storing
Intel
Change Logo Utility does not save modified BIOS capsule
Moving the RAID controller into a different slot will sometimes resolve this issue.
The Checkup7.exe utility which is used to update the processor microcode in
BIOS is not working properly. The utility says it completes the flash update
successfully, however upon the next reboot the microcode is not actually
present in the BIOS.
Users will not be able to update their BIOS with a new processor microcode.
This erratum is fixed in BIOS release R0057 and later releases.
Users will need to update to the latest BIOS revision which will include the
latest processor microcode releases. They will not be able to use this utility to
add a microcode patch to the existing BIOS.
With the Intel
become caught in a reset loop during POST. The system resets itself 4 to 5 times
before completing POST. This is seen early in POST within the first seconds of power
on and before video initialization. POST code LEDs show 0x21 "Chipset" Initializing a
chipset component.
POST will take approximately 15-20 seconds longer to complete.
This erratum is fixed in BIOS release R0057 and later releases.
Populating the card in a slower bus (x4 or x8) seems to make this issue appear
less frequently.
When using the Change Logo Utility to modify a BIOS capsule file and replace
the Intel Splash Screen logo with a new one, it fails to save the new capsule file
with a .cap extension. The file that is produced has an .fd extension. The file
is the correct capsule file, but it has the wrong extension.
Users may be confused and believe the utility is not saving the file in the
correct format.
This erratum is fixed in version 4.16 of the utility.
®
RAID Controller SRCSAS144E causes systems to
®
RAID Controller SRCSAS144E installed in the system, the system may
Intel Confidential
Enterprise Platforms and Services Marketing