5500.2041 Schurter Inc, 5500.2041 Datasheet

FILTER LINE POWER STD 6A 6.3 QC

5500.2041

Manufacturer Part Number
5500.2041
Description
FILTER LINE POWER STD 6A 6.3 QC
Manufacturer
Schurter Inc
Series
FMW-41r
Datasheets

Specifications of 5500.2041

Filter Type
Power Line
Voltage - Rated
125V, 250V
Current
6A
Mounting Type
Chassis Mount
Termination Style
Fast-On
Voltage Rating
125 VAC / 250 VAC
Current Rating
6 A
Filtered
Yes
Frequency
50 / 60 Hz
Leakage Current
0.25 mA
Capacitance
15nF
Inductance Min
800µH
Svhc
No SVHC (15-Dec-2010)
Approval Bodies
VDE, SEV, UL, CSA
Capacitance X Type Capacitor
0.015µF
Rohs Compliant
Yes
Termination Type
Tab
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Inductance
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
EMC-Power Line Filters for 1-Phase Systems
FMW2
Nominal current:
Rated voltage U
Attenuation:
Leakage current:
Test voltages:
Climatic category:
50% saturation typ.:
Inrush current:
MTBF @ 40 °C / U
The FMW2 filter-line offers a wide range of filters with diverse types of
technical characteristics, suitable for various kinds of applications.
These filters are generally used as protection against interference volt-
ages from the mains, and are mounted inside the equipment as close as
possible to the mains input. At the same time possible interferences
generated in the equipment are strongly attenuated and therefore will
not reach the mains.
(1) Current derating over 40°C : I = I
(2) Nominal inductance measured according to EN 138100, see introduction of this catalog, paragraph 3.4
(3) Measured according to IEC 60950 5.2.3 Annex D, see introduction of this catalog, paragraph 3.5
* without resistor
Case 41
Order Numbers and Technical Data
Type
Standard
5500.2039
5500.2040
5500.2041
5500.2042
Type
Medical M5
5500.2098
5500.2104
5500.2100
5500.2102
Insertion loss -
Standard
Insertion loss -
Medical M5
FMW2
FMW2
Series, all-purpose filters to Protection Class I, conform to EN 133200, UL 1283 and IEC 60950
R
(U
R
max
(U
@ ϑa 40 °C
@ ϑa 40 °C
):
max
):
I
I
N
N
[A]
[A]
10
10
1
3
6
1
3
6
(1)
(1)
1 – 10 A @ 40 °C
125/250 VAC 50/60 Hz
Standard
for Standard and Medical applications
L/N → E 2.7 kVDC, 2 sec
L → N 1.7 kVDC, 2 sec *
25/085/21 acc. to IEC 60068-1
2 to 3 x I
1.5 x I
> 200'000 h acc. To MIL-HB-217 F
N
x
N
(85-ϑa)/45
1 min. per hour
N
(Umax)
(Umax)
[VAC]
[VAC]
@ 20 °C
250
250
250
250
250
250
250
250
U
U
R
R
-30% / +50%
-30% / +50%
2 x 10
2 x 2
2 x 10
2 x 2
2 x 0.8
2 x 0.4
2 x 0.8
2 x 0.4
L
L
[mH]
[mH]
N
N
(2)
(2)
Leakage current
Leakage current
@ 250 V / 50 Hz
@ 250 V / 50 Hz
< 0.25
< 0.25
< 0.25
< 0.25
[mA]
[µA]
< 5
< 5
< 5
< 5
Optional versions:
· Medical version M80 with leakage current < 80µA
· Version with ZNR-varistor for overvoltage protection
Contact Schurter for minimum order quantity
Circuit diagram
(3)
(3)
Cx(X2)
Cx(X2)
[nF]
[nF]
15
15
15
15
15
15
15
15
Cy(Y2)
Cy(Y2)
[nF]
[nF]
2.2
2.2
2.2
2.2
www.schurterinc.com
-
-
-
-
[MΩ]
[MΩ]
R
R
1
1
1
1
-
-
-
-
Medical Versions
Standard and
Case
Case
41
41
41
41
41
41
41
41
25