PS0SSDS6A Tyco Electronics, PS0SSDS6A Datasheet - Page 4

MODULE PWR ENT DL FUSE FILTER 6A

PS0SSDS6A

Manufacturer Part Number
PS0SSDS6A
Description
MODULE PWR ENT DL FUSE FILTER 6A
Manufacturer
Tyco Electronics
Series
Pr
Type
IEC 320-C14 (Male Pins)r
Datasheets

Specifications of PS0SSDS6A

Filter Type
RFI
Current
6A
Features
Fuse Holder, Shielded, Switch, Voltage Selector
Fuse Drawer
Included
Mounting Type
Panel Mount, Snap-In
Termination Style
Quick Connect - .187" (4.7mm)
Voltage
115VAC
Current Rating
6A
Leakage Current
500µA
Approval Bodies
UL, CSA, VDE
External Depth
54.1mm
External Length / Height
58.67mm
External Width
31.49mm
Input Voltage Max
250V
Input
RoHS Compliant
Voltage Rating
250 VAC
Filtered
Yes
Product
Power Entry Filter Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
2-1609951-2
2-6609951-2
P Series
Specifications – Unfiltered Models
Hipot rating (one minute):
Operating frequency:
Rated voltage (max.):
Rated current, all unfiltered models:
Operating voltages: Selectable or fixed
Fuseholder:
Switch:
Terminals:
Voltage Selection Schemes
1) Dual Primary Transformer Type:
Note 1: Jumpers are required if a filter or interconnection module is not
Note 2: Location of optional filter. Jumpers are required if a filter or
Catalog 1654001
Revised 03-04
2) Jumper Type:
Ground
Neutral
Ground
Neutral
Hot
Hot
line-to-ground
line-to-line
used.
interconnection module is not used.
Note 1
Note 1
Note 1
Note 1
Recommended use connector - no solder
Power on/off
Power on/off
Conversion clip provided on fuseholder
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
.187 x .032 [4.8 x .81] terminal tabs
Note 1
Note 1
Double-insulated rated for 10,000
Note 2
Note 2
G
H
G
H
Provision for
single fusing
Provision for
single fusing
Accepts one or two fuses
CORCOM Product Guide
The CHAMELEON Adaptable Module for General, High Performance or
Medical Applications
51 Amp inrush capability
1/4 x 1-1/4 or 5 x 20 mm
115V
for single fuse models.
115V
operations at full load.
10A @ 120 VAC
10A @ 250 VAC
230V
C
A
B
D
230V
A
B
C
D
115/230 VAC
1500 VAC
1450 VDC
50/60 Hz
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
250 VAC
Transformer
primary
SMPS
Sel.
Jumpers
Power
input
115V
115V
(Continued)
Specifications – Filtered Models
Maximum leakage current, each line-to-ground:
Hipot rating (one minute):
Operating voltages:
Operating frequency:
Rated voltage:
Switch:
Terminals:
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
H Models
03A
06A
10A
S Models
03A
06A
10A
Z Models
06A
10A
L Models
06A
10A
Line-to-line in 50 ohm circuit
H Models
03A
06A
10A
S Models
03A
06A
10A
Z Models
06A
10A
L Models
06A
10A
Current
Current
Current
Current
Rating
Rating
Rating
Rating
@ 120 VAC 60 Hz:
@ 250 VAC 50 Hz:
line-to-ground
line-to-line
Selectable or fixed
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
.03
.01 .05
.01 .05
10
10
10
10
7
3
7
8
5
8
5
-
-
-
Conversion clip provided on fuseholder
.10
17
17
21
17
21
17
15
20
15
20
.1
2
2
2
2
2
2
8
5
8
3
.187 x .032 [4.8 x .81] terminal tabs
1-508-992-4495
49-89-6089-0
.15
.15
21
11
21
12
27
22
27
22
34
20
34
20
.1
.1
for 10,000 operations at full load.
8
4
4
4
4
4
4
5
H Models
S Models
H Models
S Models
.15 .5
.15 .5
27 30
15 17
10 12
27 33
17 23
10 13
30 37
24 27
29 34
23 24
12 18
12 16
12 16
12 15
12 15
12 15
44 75
35 67
44 75
35 67
.5
.5
Frequency-MHz
Frequency-MHz
Frequency-MHz
Frequency-MHz
51 Amp inrush capability.
Double-insulated, rated
1
1
for single fuse models
29
19
11
40
32
23
43
32
35
25
31
26
26
30
22
22
75
75
75
75
3
1
3
1
www.cor.com
www.tycoelectronics.com
115/230 VAC
120/250 VAC
26
18
11
44
36
27
49
52
25
21
40
35
33
48
42
42
75
75
75
75
5
5
5
5
1500 VAC
1450 VAC
50/60 Hz
0.25 mA
.50 mA
10
23
16
10
50
44
35
10
52
47
21
18
10
48
40
40
50
55
55
10
70
70
70
70
2 A
5 A
30
15
13
10
32
30
27
30
42
40
16
14
30
41
35
32
45
45
45
30
60
60
60
60
125

Related parts for PS0SSDS6A