5145.0885.811 Schurter Inc, 5145.0885.811 Datasheet - Page 5

no-image

5145.0885.811

Manufacturer Part Number
5145.0885.811
Description
MOD INLET/CB/STD FILTER 15A PNL
Manufacturer
Schurter Inc
Series
5145r
Type
IEC 320-C14 (Male Pins)r
Datasheets

Specifications of 5145.0885.811

Current
15A
Features
Circuit Breaker
Filter Type
General Purpose
Fuse Drawer
Fuse Not Required
Mounting Type
Panel Mount, Screw Hole
Termination Style
Quick Connect - .250" (6.3mm)
Voltage
250V
Alt Mfr.s Type
5145.ABDWF150C0.811
Current Rating
0.1 to 15 A (UL, CSA)
Dielectric Strength
> 1.5 kV (Between Line⁄Nutural)
Dimensions
91.5 mm H x 36 mm W
Material, Housing
Thermoplastic
Number Of Poles
2
Standards
UL Recognized, CSA Certified, VDE Approved
Terminal Style
Quick-Connect
Voltage, Rating
125⁄250 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power entry modules with line filter
The specifications, descriptions and illustrations indicated in this document are based on
Technical data (continued)
Circuit breaker
Tripping characteristics
I
Effect of ambient temperature
The unit is calibrated for an ambient temperature of +23 °C. To
determine the rated current for a lower or higher ambient tempera-
ture, use a correction factor from the table below.
* Ambient temperature [°C] Correction factor
–10
– 5
+23
+30
+40
+55
Order code (Order example)
Please note that Schurter will establish an internal part number for logistical use in additional to the order code. The format of this internal part
number is, for example 5145.0031.001
n
Type
5145.
[ min ]
60
30
20
10
< 3 A
5
1
0
10’000
2000
1000
[ sec ]
500
200
100
0,5
0,3
0,2
0,1
50
20
10
5
2
1
A B T W F 1 5 0 C 0
1,05
Multiple of rated current
1,32
Order code TA45
(2-pole rocker-switch without
accessories)
current information. All content is subject to modifications anamendments.
Type
Rated current
Ambient temp.
2
see table 1
3
[ x I n ]
4
5
TA45
I n < 3 A
1-pole protected
2-pole protected
+23 °C
1)
8
0,89
0,91
0,92
1,00
1,03
1,08
1,16
10
.
0 0 1
Tripping characteristics
I
n
60
30
20
10
[ min ]
5
1
10’000
2’000
1’000
3… 15 A
[ sec ]
500
200
100
0,5
0,3
0,2
0,1
50
20
10
5
2
1
1,05
Multiple of rated current
EMC products
1,32
Type
Rated current
Ambient temp.
Wiring
0 Without
1 With
Type of line filter
1 Standard
3 Medical
Rated current of line filter
1
2
3
4
2
1 (A)
2 (A)
3 (A)
4 (A)
3
* Temperature must be measured at the rear of the breaker next to
the terminals after equipment operating temperature has been
reached.
1)
Rated current at +23 °C
Ambient temperature
Correction factor
Chosen rated current at
+ 40 °C ambient temperature
[ x I n ]
Example
4
5
TA45
I ≥ 3... ≤ 15 A
1-pole protected
2-pole protected
+23 °C
n
8
5
6
7
8
10
www.schurter.com/pg06
10 (A)
15 (A)
6 (A)
8 (A)
6 A x 1,08 = 6,5 A
545
+40 °C
6,0 A
1,08
5

Related parts for 5145.0885.811