NHD-0216KZW-AB5 Newhaven Display, NHD-0216KZW-AB5 Datasheet - Page 10

DISPLAY OLED CHAR 2X16 BLU

NHD-0216KZW-AB5

Manufacturer Part Number
NHD-0216KZW-AB5
Description
DISPLAY OLED CHAR 2X16 BLU
Manufacturer
Newhaven Display
Datasheet

Specifications of NHD-0216KZW-AB5

Viewing Area (w X H)
66 mm x 16 mm
Operating Voltage
5 V
Operating Current
30 mA
Maximum Operating Temperature
+ 80 C
Minimum Operating Temperature
- 40 C
Illumination Color
Blue
Viewing Angle
80 deg
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
NHD-0216KZW-AG6
NHD-0216KZW-AG6
 
Set CGRAM Address  
This instruction is used to set the CGRAM address into the Address Counter. Data can then be written to or read from 
the CGRAM locations. See section: “How to use CGRAM”. 
ACG5..ACG0 is the binary CGRAM address.  
 
Set DDRAM Address  
This instruction is used to set the DDRAM address into the Address Counter. Data can then be written to or read from 
the DDRAM locations. 
ADD6..ADD0 is the binary DDRAM address. 
Line 1 = Address 0x00 through 0x0F 
Line 2 = Address 0x40 through 0x4F 
 
Read Busy Flag and Address Counter  
This instruction is used to read the Busy Flag (BF) to indicate if the display controller is performing an internal operation. 
The Address Counter is read simultaneously with checking the Busy Flag. 
When BF = “1”, the controller is busy and the next instruction will be ignored. 
When BF = “0”, the controller is not busy and is ready to accept instructions. 
AC6..AC0 is the binary location of either the CGRAM or DDRAM current address. 
 
 
Write Data to CGRAM or DDRAM  
This instruction is used to write 8‐bits of data to the CGRAM or DDRAM at the current address counter. After the write is 
complete, the address is automatically incremented or decremented by 1 according to the Entry Mode. 
 
 
Read Data from CGRAM or DDRAM  
This instruction is used to read 8‐bits of data to the CGRAM or DDRAM at the current address counter. After the read is 
complete, the address is automatically incremented or decremented by 1 according to the Entry Mode. 
The Set CGRAM Address or Set DDRAM Address Instruction must be executed before this instruction can be performed, 
otherwise the first Read Data will not be valid. 
 
 
RS 
RS 
RS 
RS 
RS 
R/W 
R/W 
R/W 
R/W 
R/W 
DB7 
DB7 
DB7 
DB7 
DB7 
BF 
ADD6  ADD5  ADD4  ADD3
DB6 
DB6 
DB6 
AC6 
DB6 
DB6 
ACG5 
DB5 
DB5 
DB5 
DB5 
DB5 
AC5 
ACG4 
DB4 
DB4 
DB4 
DB4 
DB4 
AC4 
Write Data
Read Data
ACG3
DB3
DB3
DB3
AC3
DB3
DB3
ADD2
ACG2
DB2
DB2
DB2
AC2
DB2
DB2
[10] 
ACG1
ADD1
DB1
DB1
DB1
DB1
DB1
AC1
ADD0
ACG0
DB0
DB0
DB0
DB0
DB0
AC0
 

Related parts for NHD-0216KZW-AB5