89750160 Crouzet USA, 89750160 Datasheet

CONTROL LOGIC ACC CVR WTRTGHT

89750160

Manufacturer Part Number
89750160
Description
CONTROL LOGIC ACC CVR WTRTGHT
Manufacturer
Crouzet USA
Type
Temperature Sensorr
Datasheets

Specifications of 89750160

Standards
UL Listed, CSA Certified, CEI and EN Approved
Termination
Screw
Voltage Rating
24 V
For Use With
SA12-EC12, Millenium 3
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
89750160
966-1008
www.millenium3.crouzet.com
Renewable energies
Water treatment
Industrial machines
The right solution - whatever
the application!
Standard &
Custom

89750160 Summary of contents

Page 1

Renewable energies ■ Water treatment ■ Industrial machines ■ www.millenium3.crouzet.com Standard & The right solution - whatever the application! Custom ...

Page 2

... New software functions (sunrise/sunset, etc.) ■ New accessories (pressure control solution, levels, fl ow, broader range of power supplies, remote display/keypad, improved communication extension performance, etc.) In addition to its Millenium 3 Standard logic controllers for today’s automation needs, Crouzet is also able to offer its Millenium 3 Custom logic controllers for specifi ...

Page 3

... XE10 - “Expandable” range/digital termination extensions XR06-XR10-XR14 - “Expandable” range/analogue termination extensions XA04 ■ Plug & Play solutions for STN and GSM modem communication ■ I/O wiring and installation diagrams Accessories by function ■ Programming ■ Installing ■ Displaying ■ ...

Page 4

Field irrigation Irrigation control based on temperature, humidity, and day/night cycle. ■ Hydraulic solar heating Automation of operation and heating regulation plus remote management of the installation via GSM modem. ■ Opening control for industrial sectional doors Opening control ...

Page 5

What is a logic controller used for? The Millenium 3 logic controller can be used to automate small devices requiring between 10 and 50 I/O. Millenium 3’s logic functions can be used in numerous applications, including packing, access control, vending, ...

Page 6

More possibilities PROCESSING ■ Supplying power Millenium 3 functions ■ Timing: 5 types of timer ■ Counting: 3 types of counter ■ Regulating: Hysteresis cycle, ■ Sensing PID, etc. ■ Archiving/saving: 10-year data backup function, even after a power failure ...

Page 7

What is a logic controller used for? Adjusting There are several options for adjusting setpoints, including an external control potentiometer on the analogue inputs and internal setpoints modifi able via the display. Actuating Millenium 3 can be used to drive ...

Page 8

The benefits of new the range ■ Modularity ■ Optimised wiring time ■ Ergonomic display ■ Mounting on DIN rail or using screws ■ Networked offer 8 Millenium 3 “Compact” range ■ With display CD12 CD20 Millenium 3 “Expandable” range ...

Page 9

Product offer overview “Compact range” starter kits with display ■ ■ Digital Digital extensions “Sandwich” extension XE10 XR06 XR10 See page 76 for other analogue “application” extensions. If you have specifi c needs, see page 62. “ Millenium 3 is ...

Page 10

More configuration options You need: Logic controller communication Millenium 3 logic controller CD12 or CB12 or XD10 or XD10/XB10 or XD26/XB26 XD10/XB10 or XD26/XB26 XD10/XB10 or XD26/XB26 + ■ Example Millenium 3 combination: XD26 + XE10 + XR14 10 Find ...

Page 11

Product offer overview all thanks to the modularity of Millenium 3. Modem communication + = = Plug & Play solutions for modem communication XE10 XN03 XN05 XN06 XE10 XN03 XN05 XN06 20 Compatible with M3MOD + XR06 XR10 XR14 XA04 ...

Page 12

For greater efficiency ■ Sprinklers ■ Drink vending machines ■ Telemaintenance for a pumping station ■ Sliding gate 12 Plug & Play solutions for modem communication With the networked logic controller, you can control your installations remotely. Using the M3MOD ...

Page 13

... Product offer overview ■ Millenium Web Server ■ Communication extensions ■ Programming accessories “ In the case of extremely remote equipment access the Millenium 3 controller remotely means we can optimise our response times. And the wireless link is a real bonus when it comes to controlling the automatic gates we have ...

Page 14

Example of programming in FBD/Grafcet SFC ■ Creating ■ Simulating ■ Supervising 14 Two programming languages With Millenium 3, programming mirrors how you work. Whether you are an electrical engineer or a control systems engineer, ...

Page 15

Introduction to programming software ■ Macro function ■ Division of screen ■ Moveable links ■ Time simulator ■ Visual customisation www.millenium3.crouzet.com Software innovations for easier programming ■ Macro function Integrating your repetitive functions into dedicated macro functions saves time and ...

Page 16

Programming that is even more natural 27 preprogrammed FBD functions ■ ■ Timing/clock TIMERS A/C function: Delay on and off BW function: Pulse on a rising or falling edge B/H function: Adjustable pulsed signal Li/L function: Pulse generator (ON/OFF setting) ...

Page 17

Introduction to programming software ■ Communication SLIN (SERIAL LINK INPUT) Writing via serial link of data stored in the controller’s fi xed addresses. SLOUT (SERIAL LINK OUTPUT) Reading via programming port of data stored in the controller’s fi xed addresses. ...

Page 18

FBDC functions (continued) ■ ■ SFC WAIT SFC STEP Sets up a wait phase or step for a PLC or a device. ■ Sensor NEW GAIN Acts as the interface between the Crouzet pressure transmitters and ...

Page 19

Introduction to programming software Ladder language The M3 SOFT CD-ROM contains all the symbols used in Ladder language. You can choose between two types of graphic representation: Ladder or electrical symbols. 13 Ladder functions ■ ■ Inputs ■ Electrical DIGITAL ...

Page 20

Whatever activity your ■ Building Management Systems ■ Industry ■ Advertising hoardings ■ Water treatment ■ Renewable energies 20 Millenium 3 offers the most suitable solution for your application. Building Management Systems ■ Lighting control systems ■ Air conditioning and ...

Page 21

Applications Focus on the “compressor” application Pressure transmitter: Easily avoid breakdowns! ■ The pressure transmitter measures the compressor’s supply and outlet pressures to control the motor according to the required displayed pressure, thereby ensuring maximum effi ciency. ■ Ready-to-use, the ...

Page 22

Millenium 3 Standard ➜ General characteristics ■ Millenium 3 Compact Range ■ Millenium 3 Expandable Range ■ Millenium 3 Communication Options General environment characteristics for CB, CD, XD, XB, XR and XE product types Certifications Conformity with the low voltage ...

Page 23

Processing characteristics of CB, CD, XD & XB product types LCD display Programming method Program size Program memory Removable memory Data memory Back-up time in the event of power failure Cycle time Response time Clock data retention Clock drift Timer ...

Page 24

Millenium 3 Standard Electrical durability for 500 000 operating cycles Minimum switching capacity Minimum load Maximum rate Mechanical life Voltage for withstanding shocks Response time Built-in protections Status indicator Characteristics of product with DC power supplied Supply Nominal voltage Operating ...

Page 25

Potentiometer control Inputs used as digital inputs Input voltage Input current Input impedance Logic 1 voltage threshold Making current at logic state 1 Logic 0 voltage threshold Release current at logic state 0 Response time Maximum counting frequency Sensor type ...

Page 26

Millenium 3 logic controllers Type Part number With display CD12 88970041 88970042 88970043 88970044 88970045 CD20 88970051 88970052 88970053 88970054 88970055 Without display CB12 88970021 88970023 88970024 NEW 88970840 CB20 88970031 88970033 88970034 ■ Ergonomic display ■ Optimum memory capacity ...

Page 27

Modem Modular power supplies communication solutions M3MOD STN GSM 88970117 88970118 88970119 88950306 ...

Page 28

... CD20 12 digital (including 6 analogue) 12 digital (including 6 analogue) 12 digital 12 digital 12 digital (including 6 analogue) Accessories Type Description M3 SOFT Multilingual programming software containing specific library functions (CD-ROM) PA EEPROM memory cartridge 3 m serial link cable USB link cable: PC ➞ ...

Page 29

... Type Input CB12 8 digital (including 4 analogue) 8 digital 8 digital 8 digital (including 4 analogue) CB20 12 digital (including 6 analogue) 12 digital 12 digital Accessories Type Description M3 SOFT Multilingual programming software containing specific library functions (CD-ROM) PA EEPROM memory cartridge ➞ serial link cable: PC Millenium 3 ➞ USB link cable: PC Millenium 3 ➞ ...

Page 30

Millenium 3 logic controllers Type Part number With XD10/ Without display XD26 display XB10/XB26 88970141 88970131 88970142 88970132 88970143 88970133 88970144 88970134 88970161 88970151 88970162 88970152 88970163 88970153 88970164 88970154 88970165 88970155 NEW 88970814 - Extensions "Sandwich" Type Part number ...

Page 31

Modem Modular power supplies communication solutions M3MOD STN GSM 88970117 88970118 88970119 88950306 ...

Page 32

... XD26 16 digital (including 6 analogue) 16 digital (including 6 analogue) 16 digital 16 digital 16 digital (including 6 analogue) 16 digital (including 6 analogue) Accessories Type Description M3 SOFT Multilingual programming software containing specific library functions (CD-ROM) PA EEPROM memory cartridge 3 m serial link cable USB link cable: PC ➞ ...

Page 33

... XB26 16 digital (including 6 analogue) 16 digital (including 6 analogue) 16 digital 16 digital 16 digital (including 6 analogue) nd *Available 2 quarter of 2008 General characteristics See page 22, except: Certifications Accessories Type Description M3 SOFT Multilingual programming software containing specific library functions (CD-ROM) PA EEPROM memory cartridge ➞ serial link cable: PC ➞ USB link cable: PC ➞ ...

Page 34

Millenium 3 Standard ➜ Sandwich communication extensions for XD10/XB10 & XD26/XB26 ■ Exchange of input/output state or of internal values via communication networks ■ Power supply via the controller Part numbers Type Description XN03 Modbus RS-485 slave communication extension 4 ...

Page 35

Digital sandwich extension for XD10/XB10 and XD26/XB26 ■ Can be used to reach inputs/outputs in conjunction with XR14 termination extensions ■ Relay outputs one of which is a changeover relay Part numbers Type Input XE10 6 ...

Page 36

Millenium 3 Standard ➜ Digital extension for XD10/XB10 and XD26/XB26 ■ Power supply via the controller at the same voltage as the inputs ■ Number of inputs/outputs can be configured in accordance with your requirements Part numbers Type Input XR06 ...

Page 37

Characteristics of analogue extension 88970241 General characteristics of analogue extension 88970241 See page 22, except: Certifications Earthing Analogue inputs Inputs used as analogue inputs Input Input range Input impedance Maximum non destructive current/voltage Value of LSB Input type Resolution Conversion ...

Page 38

... GSM modem for wireless communication Part numbers Type Description M3MOD Modem communication interface STN STN modem GSM GSM modem 850/900/1800/1900 MHz Accessories Type PA M3 ALARM Characteristics of the communication Modem system General characteristics of the modem communication See page 22, except: Certifications Power supply Nominal voltage (V) Operating limits ...

Page 39

Data characteristics Data saved by the interface Backup of data to be sent Functions available depending on the hardware architecture and/or type of SIM card Functions Functions Send alarm/receive instructions with GSM telephone Send alarm/receive instructions with PC running "M3 ...

Page 40

Millenium 3 Standard ➜ I/O wiring Inputs Bases : CD12, CD20, CB12, CB20, XD10, XD26, XB10, XB26 Extensions : XE10, XR06, XR10, XR14 + V Millenium 3-wire PNP sensor ...

Page 41

Relay outputs Bases : CD12, CD20, CB12, CB20, XD10, XD26, XB10, XB26 Extensions : XE10, XR06, XR10, XR14 Millenium Solid state outputs Bases : CD12, CD20, CB12, CB20, XD10, XD26, ...

Page 42

Millenium 3 Standard ➜ Input/output installations: Bases "Compact" range : CD12, CD20, CB12, CB20 Inputs CD12, CB12 + Relay ...

Page 43

Input/output installations: Extensions "Sandwich" communication extensions : XN03, XN05, XN06 XN03, XN06 COM PWR MB485-V1 Digital "Sandwich" extensions : XE10 Inputs ...

Page 44

... Millenium 3 accessories ➜ Programming tools and software ■ Millenium 3 software: multilingual software, intuitive operation ■ Memory card for loading the application and updating the on-board software (firmware) Part numbers Type Description M3 SOFT Multilingual programming software containing specific library functions (CD-ROM) M3 ALARM ...

Page 45

... IP40 faceplate: CD20 or XD26 Dimensions (mm) IP67 IP40 88750160 = 91 88750161 = 162 88750162 = 257.4 C 88750160 = 76.5 88750161 = 147.5 88750162 = 248.5 www.millenium3.crouzet.com IP67 B 88750160 = 91 20 88750161 = 162 88750162 = 257.4 C 88750160 = 76.5 88750161 = 147.5 88750162 = 248.5 76,5 91,5 28 71,5 4 ø10 IP40 Code 89750160 89750161 89750162 88970809 88970810 50 45 ...

Page 46

... Millenium 3 accessories ➜ Remote LCD alphanumeric displays (Modbus communication) ■ Set and parameterise your application data in advance ■ Backlit LCD screen ( mm) with 4 lines of 20 characters and keypad with 8 keys which can be renamed - Three-colour screen: 3 colours green/orange/red - Monochrome screen: Monochrome green ■ ...

Page 47

... Millenium 3 accessories ➜ Remote LCD displays/keypads ■ Direct link with Millenium 3 via cable ■ Set and parameterise your application data in advance ■ Backlit LCD screen with 4 lines of 18 characters and keypad with 6 keys or 10 keys and 4 LEDs ■ Direct communication with the Millenium 3 via the programming port ■ ...

Page 48

... Millenium 3 accessories ➜ Remote LED display - Input 0-10 V ■ Set your application data in advance ■ Display (36 x 72) with red digits ■ Configurable display range ■ 0-10 V input ■ IP65 degree of protection on front panel Part numbers Type Description RD Display with red digits ...

Page 49

Potentiometer Ø ■ Direct-read potentiometer (controlled externally) Ø ■ IP65 degree of protection on front panel ■ Directly compatible with the "Potentiometer" parameter of an analogue input on the Millenium 3 Part numbers Type Description ...

Page 50

... Millenium 3 accessories ➜ Signal converters ■ Current/voltage conversion of Millenium 3 input signals ■ PWM/voltage conversion of Millenium 3 output signals Part numbers Type Description AC 0-20 mA/0-10 V input converter PWM/0-10 V output converter General characteristics Environmental characteristics Certifications Protection rating Operating temperature Storage temperature Electrical characteristics ...

Page 51

Temperature converters ■ Compatible with Millenium 3 analogue inputs ■ Can be used to diversify the type of sensors for analogue inputs (See page 54-55) Part numbers Type Description AC Converter Converter Converter Converter Converter Converter General characteristics Environmental ...

Page 52

... Millenium 3 accessories ➜ Analogue pressure transmitters 4-20 mA ■ Dry, robust pressure transmitter ■ Ceramic variable capacitance sensing element ■ Withstands high static and dynamic overload pressures ■ Standard Ranges between 0.25 bar and 100 bar (Abs / Rel) ■ Fully Factory Calibrated & Temperature Compensated ■ ...

Page 53

Connections With resistor (500 Ω recommended 500 Ω 600Ω - max 24VDC Simple & economic solution + B Terminal + C Terminal - D M3 ...

Page 54

... Millenium 3 accessories ➜ Temperature sensors: Pt 100 & Thermocouple ■ Thermocouple J: - Nickel-plated brass eyelet - Stainless steel casing - Stainless steel sheath ■ Thermocouple K ■ Pt 100 Class B: - Stainless steel sheath - Aluminium vee ■ Connection / Sub-base / Flange ■ Pt100 for use with XA04 extension (See pages 40-41) ■ ...

Page 55

Dimensions (mm) Sub-base: 79696041 across flat Thermocouple probe J : 79696030 2000 Thermocouple probe J : 79696032 2000 Thermocouple probe K : 79696034 1 500 45 2000 Ø 3 Ø Flexible ...

Page 56

... Millenium 3 accessories ➜ Temperature sensors ■ Integrated converter: 0-10 V output for direct connection to the Millenium 3 analogue inputs Part numbers Type Description AS Zone/space Ventilation duct External Remote/submersible probe Remote/submersible probe Accessories Accessories Copper protective sleeve 316 stainless steel protective sleeve Heat transfer compound ...

Page 57

DC/DC converters ■ Power supplies for extended power ranges ■ Provide your devices with a constant supply voltage ■ Primary/secondary isolation Part numbers Type Input PS 9-18 V 9-36 V General characteristics See page 20, except: Certifications Output voltage ...

Page 58

... Millenium 3 accessories ➜ Millenium power supply ■ With a switch mode power supply, regulated and protected against overloads and short-circuits, these new power supply units are easily integrated in switchboards and enclosures. ■ The potentiometer can be used to set the output voltage between 100 and 120% (24 V compensate for any voltage drops on the line. ■ ...

Page 59

Dimensions (mm) 66,6 51,6 4 56,1 Curves Derating The ambient operating temperature of the Millennium power supplies is 55°C. Above this, a derating is needed upto a maximum operating temperature of 70°C. The chart below shows the power (compared to ...

Page 60

... PFC ➞ 100 240 115 / 230 115 / 230 Accessories Description Mounting bracket Snap-on plate for 35 mm DIN rail General characteristics Certifications Conformity to standards Output circuit Status indication Operating voltage Nominal output current Output voltage accuracy Line and load regulation ...

Page 61

Dimensions (mm) 89450 power supplies 1 8,5/0,33 2 2,5 0,10 B 89450110-210 : 144 mm 89450221-231-241 : 194 mm 89450122-222-232-242 : 194 mm C 89450110-210 : 150 mm 89450221-231-241 : 200 mm 89450122-222-232-242 : 200 mm D 89450110-122-210-221 : 38 ...

Page 62

For even greater customisation ■ Application-based marketing ■ Software adaptations ■ Hardware adaptations ■ Enhanced EMC tests ■ Optimised prototype tests 62 A catalogue offer: adapted products In addition to its Millenium 3 Standard logic controllers for today’s automation needs, ...

Page 63

... Millenium 3 XD10 Millenium 3 adapted application-specifi c kit Components with added value Standard products complemented by factory-mounted auxiliaries or accessories (connectors, wire outputs, cables, etc.) in order to assist integration into your equipment, simplify your logistics and maximise the reliability of your installation. 63 ...

Page 64

For more adaptations ■ “Modular” versions ■ “Bare board” versions ■ “Resin board” versions ■ Application-specifi c extensions 64 Adapted products Crouzet offers a Millenium 3 Custom “Catalogue” range based on the Millenium 3 Standard range whereby characteristics have been ...

Page 65

Hardware adaptation capability ■ Specifi c EMC tests ■ Electronics adaptation ■ Changing the number of I/O www.millenium3.crouzet.com Specific products Crouzet can also provide Millenium 3 Custom solutions adapted as required to meet any specifi cation: Toughening ■ Resistance to ...

Page 66

For more adaptations ■ Example of program using Custom functions ■ Example of a y=f(x) transfer function from a spreadsheet ■ Morning Pulse: Start before sunrise End: 09.00 ■ Evening Pulse: Start: 16:00 End ...

Page 67

Software adaptation capability ■ Developing dedicated functions ■ Function for compressor ■ Function for solar panels “ To help me design my solar panels, an application-specifi c function. Millenium 3 turns the panels towards the sun and checks its actual ...

Page 68

For more adaptations Application: Controlling water quality in a swimming pool. ■ Control systems located in machine rooms. ■ Manufacturers of swimming pools, OEM wholesalers of swimming pools. Description of customer needs: ■ Control physical fi ltration of water (using ...

Page 69

... Crouzet solution: ■ Millenium 3 logic controller. ■ Millenium 3 accessories: - NTC: temperature (°C) probe – probe providing resistance as a function of the temperature. Connects directly to the analogue inputs (0-10 V). A dedicated function block enables resistance to be converted into temperature. ...

Page 70

Millenium 3 Custom ➜ "Application-specific" and grouping adapted kits ■ Discover just what Millenium 3 can do for you - its complete kits provide everything you need for your application ■ Product groups: in order to facilitate logistics, we can ...

Page 71

... NB20 12 digital (of which 6 are analogue) 12 digital NBxx In accordance with your requirements In accordance with your requirements In accordance with your requirements Accessories Type M3 SOFT PA General characteristics See page 22, except: Protection rating Certifications Dimensions (mm) ...

Page 72

Millenium 3 Custom ➜ Modular version ■ "Modular" versions designed for Custom application specific functions and "application-specific" extensions (XA03, XA04W) for expandable range. ■ Open to "standard" extensions (XN,XR,XE,XA) ■ LCD with 4 lines of 18 characters and configurable backlighting ...

Page 73

... General characteristics See page 22, except: Certifications Operating temperature* Storage temperature* LCD display * : Available last quarter of 2008 Accessories Type Designation M3 SOFT Multilingual programming software containing specific library functions (CD-ROM) PA EEPROM memory cartridge ➞ serial link cable: PC Millenium 3 ➞ USB link cable: PC Millenium 3 ➞ ...

Page 74

... Relay outputs with connectors Relay outputs with connectors NBR32 Relay outputs with connectors NBR40 Relay outputs with connectors NBRxx Relay or solid state outputs, connectors or wires Accessories Type M3 SOFT PA MA General characteristics See page 22, except: Certifications Protection index Mechanical resistance IEC 61373 ...

Page 75

Dimensions (mm) NBR12 100 76 6 NBR32 190 166 4 Ø 6 NBR40 225 201 4 Ø 6 Input / Output Connections See Page 80-81 for details or to find instruction sheets visit: www.millenium3.crouzet.com in "Download" Product adaptations ■ 40 ...

Page 76

... XA03 3 Pt 100 (-25 +125°C) XA04W 1 Pt 100 (0-50°C (0-14), 1 ORP (0-1000mV), 1 current (4-20 mA) Accessories Type Description M3 SOFT Multilingual programming software containing specific library functions (CD-ROM) General characteristics See General characteristics for the XA04 analogue extension on page 36, except for the adapted characteristics below: ...

Page 77

Dimensions (mm) XA03 35,5 25 57,4 70 Input / Output Connections See Page 80-81 for details or to find instruction sheets visit: www.millenium3.crouzet.com in "Download" Product adaptations ■ 3-wire Pt 1000 inputs ■ Adjustable temperature range ■ Option ...

Page 78

Millenium 3 Custom ➜ pH & ORP probes for XA04W ■ High quality measurement electrode ■ 2 types of ferrule ■ Fields of application: - Swimming pools - Monitoring and treatment of drinking water - Freshwater or seawater aquariums - ...

Page 79

... HVAC - Compressors - Geothermal systems Part numbers Type Description AS NTC probe (batch of 10) for Millenium 3 (24 V NTC probe (batch of 100) for Millenium 3 (24 V Accessories Accessories Operating temperature ➞ Copper protective sleeve -20 ➞ 316 stainless steel protective sleeve -20 General characteristics Environmental characteristics Operating temperature ...

Page 80

Millenium 3 Custom ➜ I/O wiring Inputs/Outputs: NB & NBR See pages (same as CD, CB, XD, XB) Analogue inputs: XA03 & XA04W Extension : XA04W ORP/Redox D Analogue ...

Page 81

Input/output installations Bare boards (NB12, NB20) & resin boards (NBR12, NBR26, NBR32, NBR40) Inputs NB12, NBR12 + NBR26 ...

Page 82

More information is available on our site: ■ What is a logic controller used for? ■ Advantages of Millenium 3 ■ Product overview ■ Introduction to the software ■ Millenium 3 pressure solution ■ Adaptation wheel ■ Adapted products ■ ...

Page 83

... Web pages ■ Compact range selection guide ■ Expandable range selection guide ■ Starter kits ■ Communication solutions ■ Accessories ■ Download PDF documents: v Technical documents v Promotional material v Installation manuals v Demo software v Media gallery ■ Search by part number facility ■ Technical data ■ ...

Page 84

Internet: www.millenium.crouzet.com To: CROUZET Re: Project DESCRIPTION OF YOUR PROJECT Name of your application Why do you need a logic controller? Application Before project Project to be fi nalised by (date) Estimated quantity: 84 FAX From: Department: Tel.: Fax: E-mail: ...

Page 85

DETAILS OF YOUR POWER SUPPLY Direct current ❏ ❏ Alternating current ❏ ❏ 100-240 V AC ❏ Frequency .................................................................. Maximum power supply limits: ........................................ YOUR SENSORS TO BE CONNECTED ❏ Digital ...

Page 86

How to order 86 ■ Millenium 3 standard products held in stock ■ Millenium 3 standard products that can be ordered ■ Millenium 3 products made to specifi cations (contact us) www.millenium3.crouzet.com ...

Page 87

Part numbers index List of part numbers Part numbers Name 18373112 Heat transfer compound for temperature probe 26450100 Snap-on plate for 35 mm DIN rail 26450101 Mounting bracket 79696030 Thermocouple probe J - 400°C 79696031 Thermocouple probe J - 600°C ...

Page 88

Part numbers Name 88970033 Compact version logic controller without display 88970034 Compact version logic controller without display 88970041 Compact version logic controller with display 88970042 Compact version logic controller with display 88970043 Compact version logic controller with display 88970044 Compact ...

Page 89

Part numbers index Part numbers Name 88970163 Expandable version logic controller with display 88970164 Expandable version logic controller with display 88970165 Expandable version logic controller with display 88970211 Digital termination extension 88970213 Digital termination extension 88970214 Digital termination extension 88970215 ...

Page 90

Part numbers Name 88973001 Resin version logic controller 88973002 Resin version logic controller 88973061 Resin version logic controller 88973062 Resin version logic controller 88973063 Resin version logic controller 88973211 Resin version logic controller 88973231 Resin version logic controller 88974021 Compact ...

Page 91

... Room temperature transmitter 89750151 Ventilation duct temperature transmitter 89750152 Outdoor temperature transmitter 89750153 Remote/submersible temperature transmitter 89750155 Remote/submersible temperature transmitter 89750160 IP67 sealed faceplate adaptor (76.5 mm) 89750161 IP67 sealed faceplate adaptor (147.5 mm) 89750162 IP67 sealed faceplate adaptor (248.5 mm) 89750170 pH BNC probe 89750171 ...

Page 92

Headquartered in Moorpark, California-USA, Sensors & Technologies (CST) is made up of the leading brands of Crouzet, Kavlico and Crydom, as well as the former divisions of BEI Technologies, including Newall and Systron Donner. CST provides sensors, controls, and actuation ...