Y92A-72C Omron, Y92A-72C Datasheet - Page 23

COVER HARD PLASTIC FOR H5S

Y92A-72C

Manufacturer Part Number
Y92A-72C
Description
COVER HARD PLASTIC FOR H5S
Manufacturer
Omron
Datasheets

Specifications of Y92A-72C

Accessory Type
Cover
Product
Accessories
For Use With/related Products
H5S-B
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
Y92A72C
Using Advanced Functions
About Advanced Functions
Set the advanced functions as required to perform more advanced
operation. Outlines of the advanced functions are provided on the
following pages.
Refer to the Instruction Manual enclosed with the H5S for details.
Initial Setting Mode
<2-circuit
<4-circuit
Weekly, 2 Circuits
Program setting mode
PRGM
RUN
RUN
P1
P2
models
models
or
>
>
RUN
Press
for 3 s or more.
P1
P2
TIME ADJ
Yearly, 2 Circuits
Press briefly
TIME ADJ
Press briefly
Press briefly
Press briefly
Press briefly
Press briefly
Press briefly
Press briefly
Press briefly
TIME ADJ
TIME ADJ
TIME ADJ
TIME ADJ
TIME ADJ
TIME ADJ
TIME ADJ
TIME ADJ
F8:Season switching *Yearly models only
F9:Period of season *Yearly models only
F7:Summer time
schedule selection
F3:Total time alarm
F6:Summer time
(DST) adjustment *Yearly models only
F1:Next operation display
F2:Input selection
F4:Total count alarm
F5:Date format
selection
.
.
.
.
.
.
.
.
.
Initial setting mode
Yearly, 4 Circuits
*2-circuit models only
*Yearly models only
*Yearly models only
Only when "auto"
is selected in F6.
Only when "on"
is selected in F8.
*Only when "totl"
is selected in F2.
*Only when "totl"
is selected in F2.
Time Counter/Total Counter Display
(F2, F3, F4)
This function displays the total elapsed time and total input count for
an external input.
The alarm indicator can also be displayed if an alarm value has been
set.
Note: For display details, refer to Display Switching on page 22.
Input selection (F2)
• Set Input selection (F2) in initial setting mode to Time Counter/Total
Alarm for time counter (F3)
Alarm for total counter (F4)
when the total elapsed time
Yearly, 2 Circuits
Shaded portion indicates
blinking of the indicator.
Shaded portion indicates
blinking of the indicator.
Note: The default setting
Shaded portion indicates
blinking of the indicator.
Note: The default setting
Counter.
(Example shows display
Time counter display
is 30,000 hours.)
is 0.0 h (no alarm
display).
is 0 (no alarm
display).
Yearly, 2 Circuits
indicator
1. Press
2. Press
1. The display will automatically change
2. Press
*
1. The display will automatically change
2. Press
*
Alarm
m
m
h
h
Pressing
Pressing
key that was last pressed.
key that was last pressed.
display to totl.
to the alarm setting screen 2 s after
switching to F3.
Press the
to the alarm setting screen 2 s after
switching to F4.
Press the
Key: Increments in units of 1,000 h*
Key: Increments in units of 10 h*
Key: Increments in units of 10,000*
Key: Increments in units of 100*
WRITE
WRITE
WRITE
h
or
decrements the value of the
decrements the value of the
h
h
(Example shows display
m
or
or
Total counter display
to enter the setting.
to enter the setting.
to enter the setting.
when the total input
count is 500,000.)
to change the
m
m
.
.
H5S
23