K34-C2 Omron, K34-C2 Datasheet - Page 12

RELAY OUTPT BOARD HH/H/LL/L K3HB

K34-C2

Manufacturer Part Number
K34-C2
Description
RELAY OUTPT BOARD HH/H/LL/L K3HB
Manufacturer
Omron
Datasheets

Specifications of K34-C2

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
K34C2
■ Characteristics
Display range
Sampling period
Comparative output response time 100 ms max.
Linear output response time
Insulation resistance
Dielectric strength
Noise immunity
Vibration resistance
Shock resistance
Weight
Degree of
protection
Memory protection
Applicable standards
EMC
Front panel
Rear case
Terminals
−19,999 to 99,999
20 ms (50 times/second)
150 ms max.
20 MΩ min. (at 500 VDC)
2,300 VAC for 1 min between external terminals and case
100 to 240 VAC models:
24 VAC/VDC models:
Frequency: 10 to 55 Hz; Acceleration: 50 m/s
150 m/s
Approx. 300 g (Digital Indicator only)
Conforms to NEMA 4X for indoor use (equivalent to IP66)
IP20
IP00 + finger protection (VDE0106/100)
EEPROM (non-volatile memory)
Number of rewrites: 100,000
UL61010C-1, CSA C22.2 No. 1010.1 (approval pending)
EN61010-1 (IEC61010-1): Pollution degree 2/Overvoltage category II
EN61326: 1997, A1: 1998, A2: 2001
EMI: EN61326+A1 industrial applications
Electromagnetic radiation interference
Terminal interference voltage
EMS: EN61326+A1 industrial applications
Electrostatic Discharge Immunity
Radiated Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
Conducted Disturbance Immunity
Voltage Dips and Interruptions Immunity
±1,500 V at power supply terminals in normal or common mode
(waveform with 1-ns rising edge and pulse width of 1 µs/100 ns)
±1,500 V at power supply terminals in normal or common mode
(waveform with 1-ns rising edge and pulse width of 1 µs/100 ns)
CISPR 11 Group 1, Class A: CISPRL16-1/-2
CISPR 11 Group 1, Class A: CISPRL16-1/-2
EN61000-4-2: 4 kV (contact), 8 kV (in air)
EN61000-4-3: 10 V/m 1 kHz sine wave amplitude modulation (80 MHz to 1 GHz)
EN61000-4-4: 2 kV (power line), 1 kV (I/O signal line)
EN61000-4-5: 1 kV with line (power line), 2 kV with ground (power line)
EN61000-4-6: 3 V (0.15 to 80 MHz)
EN61000-4-11: 0.5 cycle, 0°/180°, 100% (rated voltage)
2
(100 m/s
2
for relay outputs) 3 times each in 3 axes, 6 directions
2
, 10 sweeps of 5 min each in X, Y, and Z directions
Weighing Indicator
K3HB-V
B-19