MLPS0000 Red Lion Controls, MLPS0000 Datasheet - Page 2

POWER SUPPLY MICRO LINE/SENSOR

MLPS0000

Manufacturer Part Number
MLPS0000
Description
POWER SUPPLY MICRO LINE/SENSOR
Manufacturer
Red Lion Controls
Datasheet

Specifications of MLPS0000

Accessory Type
Power Supply
For Use With/related Products
CUB4, CUB5 & DT7
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
RLCMLPS
Red Lion Controls
20 Willow Springs Circle
York PA 17402
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
SPECIFICATIONS (Cont’d)
4. CERTIFICATIONS AND COMPLIANCES: (Cont’d)
INSTALLATION ENVIRONMENT
maximum operating temperature and provides good air circulation. Placing
the unit near devices that generate excessive heat should be avoided.
Installation Procedure
necessary hardware to mount to the rear
of an installed backlight version Micro-
Line unit. The user must remove the
common and V+ screw terminals on the
rear of the Micro-Line unit (Save these
screw terminals for later use). Install the
1/4" hex drive stand-offs into the
common and V+ terminals. The MLPS is
then mounted to the stand-offs using the
screw terminals from the compatible
Micro-Line unit with the supplied square
washers. AC power can then be
connected to the terminal block of the
MLPS.
Note: Make sure the A.C.
ELECTROMAGNETIC COMPATIBILITY
Immunity to EN 50082-2
Electrostatic discharge
Electromagnetic RF fields
Fast transients (burst)
RF conducted interference
Power frequency magnetic fields
Emissions to EN 50081-1
RF interference
The unit should be installed in a location that does not exceed the
The MLPS is shipped with all the
selector switch is set to
the appropriate position
before applying power
to the unit.
IECEE CB Scheme Test Certificate # US/5685/UL
CB Scheme Test Report # 01ME22279-01302002
IEC 1010-1, EN 61010-1: Safety requirements for electrical equipment
Issued by Underwriters Laboratories, Inc.
for measurement, control, and laboratory use, Part 1.
EN 61000-4-2 Level 2; 4 Kv contact
EN 61000-4-3 Level 3; 10 V/m
EN 61000-4-4 Level 4; 2 Kv I/O
EN 61000-4-6 Level 3; 10 V/rms
EN 61000-4-8 Level 4; 30 A/m
EN 55011
Level 3; 8 Kv air
80 MHz - 1 GHz
Level 3; 2 Kv power
150 KHz - 80 MHz
Enclosure class B
Power mains class B
Fax +31 (0) 334 893 793
NL - 3821 BR Amersfoort
Tel +31 (0) 334 723 225
Red Lion Controls BV
Basicweg 11b
5. CONSTRUCTION: High impact black plastic. Two hex stand-offs and two
6. CONNECTION: Two position terminal block which accepts one 14 AWG
7. WEIGHT: 4 oz (113 g)
TROUBLESHOOTING
company numbers listed.
washers included. Installation Category II, Pollution Degree 2.
wire (torque terminal screws to 5 inch-lbs. [-6Nm]).
For further technical assistance, contact technical support at the appropriate
31, Kaki Bukit Road 3 #06-04/05 TechLink
Red Lion Controls Asia
Fax +65 6743-3360
Tel +65 6744-6613
Singapore 417818