E5C2-R20K AC100-120 0-200 Omron, E5C2-R20K AC100-120 0-200 Datasheet - Page 2

no-image

E5C2-R20K AC100-120 0-200

Manufacturer Part Number
E5C2-R20K AC100-120 0-200
Description
CONTROLLER TEMP ON/OFF 100V
Manufacturer
Omron
Series
E5C2r
Type
Temperature Controller, Analogr

Specifications of E5C2-R20K AC100-120 0-200

Input Type
Thermocouple (K)
Controller Type
On/Off
Temperature Range
0 ~ 200°C
Output Type
Relay
Supply Voltage
100 ~ 120VAC
Size
48mm W x 48mm H (1/16 DIN)
Features
8-Pin Plug In Mounting
Display Type
Scale
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Communications
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E5C2-R20KAC100-1200-200
E5C2R20KAC1001200200
Standard Models (Power Supply: 100 to 120 VAC)
Note: Ask your OMRON representative about models with 200 to 240
■ Accessories (Order Separately)
Sockets
Specifications
■ Ratings
Note: 1. Specify either 100/110/120 VAC or 200/220/240 VAC when
Input/
stan-
dard
scale
(°C)
Front Connecting Socket
Back Connecting Socket
Front Connecting Socket with Finger Protection P2CF-08-E
Protective Cover (for finger protection)
Supply voltage
Operating voltage
range
Power
consumption
Input
Control method
Setting method
Indication
method
Control output
Ambient operat-
ing temperature
Ambient operat-
ing humidity
VAC power supply.
2. Do not use an inverter output as the power supply. (Refer to
Thermo-
couple
Input
ordering.
Safety Precautions for All Temperature Controllers.)
K (CA)
Chromel
vs. alumel
J (IC)
Iron vs.
constantan
Indication method
100 to120 VAC 50/60 Hz
200 to 240 VAC 50/60 Hz (See note 1.)
90% to 110% of rated supply voltage
Approx. 2 VA
Thermocouple (with sensor burnout detection
circuit), platinum resistance thermometer, or
thermistor with replaceable element
ON/OFF or proportional control
Analog setting
No indication
Relay output: SPDT, 3 A at 250 VAC, resistive
−10°C to 55°C (with no icing or condensation)
45% to 85%
Name
Control mode
0 to 200
0 to 300
0 to 400
0 to 600
0 to 800
0 to 1,000 E5C2-R20K
0 to 1,200 E5C2-R20K
0 to 200
0 to 300
0 to 400
Output
load (switching capacity: 330 VA)
E5C2-R20K
E5C2-R20K
E5C2-R20K
E5C2-R20K
E5C2-R20K
E5C2-R20J
E5C2-R20J
E5C2-R20J
ON/OFF
No indication
Relay
P2CF-08
P3G-08
Y92A-48G
E5C2-R40K
E5C2-R40K
E5C2-R40K
E5C2-R40K
E5C2-R40K
E5C2-R40K
E5C2-R40K
E5C2-R40J
E5C2-R40J
E5C2-R40J
Proportional
Model
(P)
Protective Cover
■ Characteristics
Note: 1. No reset function is incorporated by any E5C2 model with
Input/
stan-
dard
scale
(°C)
Hard Protective Cover
Setting accuracy
Hysteresis
Proportional band
Control period
Reset range
Insulation
resistance
Dielectric strength
Vibration
resistance
Shock resistance
Life expectancy
Weight
Degree of protection Front panel: IEC standard IP40 (See note 2.)
Applicable Socket
Applicable Protec-
tive Cover
2. A special Watertight Cover is used to achieve this degree of
Resis-
tance
Ther-
mome-
ter
Ther-
mistor
Input
ON/OFF control.
The reset function is used to correct offset for proportional
control. If there is an offset below the set value, turn the
reset adjustment clockwise.
protection (IP66, NEMA4). Refer to Y92A-
Type
Platinum
resistance
thermom-
eter Pt100
THE (re-
placeable
element)
Indication method
±2% FS max.
Approx. 0.5% FS (fixed)
3% FS (fixed)
Approx. 20 s
5 ±1% FS min. (See note 1.)
20 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min between charged termi-
nals and uncharged metallic parts
Malfunction: 10 to 55 Hz, 0.15-mm single amplitude for
Destruction: 16.7 Hz, 2-mm double amplitude for 2 hrs
Malfunction: 147 m/s
Destruction: 294 m/s
Electrical:
Approx. 200 g (with flush-mounting adapter)
Terminals:
P2CF-08 (order separately),
P3G-08 (order separately)
Y92A-48B (order separately)
Control mode
−50 to 50 E5C2-R20P-D
−20 to 80 E5C2-R20P-D
0 to 50
0 to 100
0 to 200
0 to 300
0 to 400
−50 to 50 E5C2-R20G
0 to 100
50 to 150 E5C2-R20G
100 to 200 E5C2-R20G
150 to 300 E5C2-R20G
Y92A-48B
Output
10 min each in X, Y, and Z directions
each in X, Y, and Z directions
100,000 operations min. (3 A at 110 VAC,
resistive load)
IEC standard IP00
E5C2-R20P-D
E5C2-R20P-D
E5C2-R20P-D
E5C2-R20P-D
E5C2-R20P-D
E5C2-R20G
Model
2
2
, 3 times each in 6 directions
, 3 times each in 6 directions
ON/OFF
No indication
Relay
@@
Proportional (P)
E5C2-R40P-D
E5C2-R40P-D
E5C2-R40P-D
E5C2-R40P-D
E5C2-R40P-D
E5C2-R40P-D
E5C2-R40P-D
---
---
---
---
---
N.
E5C2
2