H7EC-NV-B Omron, H7EC-NV-B Datasheet - Page 5

COUNTER TOTALIZER 1KHZ DC INPUT

H7EC-NV-B

Manufacturer Part Number
H7EC-NV-B
Description
COUNTER TOTALIZER 1KHZ DC INPUT
Manufacturer
Omron
Series
H7ECr
Datasheets

Specifications of H7EC-NV-B

Count Rate
1kHz
Number Of Digits/alpha
8
Input Type
Voltage
Voltage - Supply
None Required (Battery Included)
Display Type
LCD Non-Backlit
Voltage Rating
4.5 VDC to 30 VDC
Mounting
Flush Mounting Adapter
No. Of Digits / Alpha
8
Digit Height
8.6mm
Counting Speed
1kHz
Operating Temperature Range
-10°C To +55°C
Signal Input Type
PNP/NPN DC Voltage
Ip/nema Rating
IP66 / NEMA 4
Panel Cutout Height
22.2mm
Mounting Type
Flush
Panel Cutout Width
45mm
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
H7EC-BVM
H7ECNVB
Z865

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
H7EC-NV-BH
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
Installation
Dimensions
Unit: mm (inch)
J H7EC-N
J TERMINAL ARRANGEMENT
Bottom view: View of the Total Counter rotated horizontally 180°
H7EC
Backlight Model
Dimensions with Flush Mounting Bracket
Count
input
Reset
input
Backlight
24 VDC
Non-backlight Model
(1.38)
(0.94)
35
24
Count
input
(1.89)
(1.76)
44.8
48
Reset
input
5
(1.46)
37
(1.91)
48.5
(0.87)
22
60 min.
Waterproofing is not possible
for joint mounting
When mounting, insert the Counter into
the cutout. Insert the adapter from the
back and push in the Counter while
making the gap between the front panel
and the cutout panel as small as
possible. Use screws to secure the
Counter. If waterproofing is desired,
insert the waterproof packing.
When several Counters are installed,
ensure that the ambient temperature
will not exceed specifications.
The appropriate thickness of the panel
is 1 to 5 mm.
Separate mounting
Panel Cutout
Joint mounting
45
+0.5
(48 ¢Units - 2.5)
0
60 min.
22.2
+0.5
0
+10
0
22.2
H7EC
+0.5
0