H7ET-NFV1-B Omron, H7ET-NFV1-B Datasheet - Page 11

COUNTER TIME 99HRS AC/DC INPUT

H7ET-NFV1-B

Manufacturer Part Number
H7ET-NFV1-B
Description
COUNTER TIME 99HRS AC/DC INPUT
Manufacturer
Omron
Series
H7ETr
Datasheets

Specifications of H7ET-NFV1-B

Operating Mode
Accumulative
Output Type
None
Voltage - Supply
None Required (Battery Included)
Termination Style
Screw Terminal
Display Type
LCD Non-Backlit
No. Of Digits / Alpha
7
Digit Height
8.6mm
Operating Temperature Range
-10°C To +55°C
Signal Input Type
AC/DC Voltage
Ip/nema Rating
IP66 / NEMA 4
Panel Cutout Height
22.2mm
Mounting Type
Panel
Panel Cutout Width
45mm
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H7ET-FBV1
H7ET-NFV1-BQ
H7ETNFV1B
H7ETNFV1BQ
Z874

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
H7ET-NFV1-B
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
J UNIT LABEL FOR TIME COUNTER AND
A unit label has been packed with the Counter. Use in
accordance with the application.
J BATTERY REPLACEMENT
Remove the wiring when replacing the Battery. Do not come in
contact with any item to which high voltage is being applied.
Doing so may result in electric shock.
Before changing the Battery, be sure that you are not carrying
any static electric charge.
Procedure for replacing the Battery (refer to the diagrams below):
When the internal Battery nears expiration, the display may
flicker.
H7ET
1. Using the tool, pry open the lift-tab on the case. (1)
2. Pull the body out of its outer case. (2)
3. Lift the Battery up by the edge and remove it. (3)
4. Wipe the back of the new Battery before inserting it.
5. Ensure that the + and - - terminals are correctly oriented.
6. After replacing the Battery, re-insert the body into its case. (4)
7. Press the Reset Key before use (not necessary for
TACHOMETER
(5)
When removing the Battery, do not come in contact with the
display area or any internal parts.
Check that the case is securely held in by the lift-tab.
H7ET-N,-NV,-NV1). (5)
(1)
(1)
(4)
Tool
(3)
(2)
11
J EN/IEC STANDARDS
The counter input, reset input, and backlight power supply
terminals of the no-voltage input or PNP/NPN universal DC
voltage input models (H7Ej-N,-N1, H7Ej-NV(-H),-NV1(-H)) are
not isolated.
A SELV power supply conforming to Appendix H of IEC61010-1
should be used for the counter input, reset input and backlight
power supply terminals. A SELV power supply is a power supply
for which the input and output have double or reinforced
insulation, and for which the output voltage is 30 Vrems with 42.4
V peak or 60 VDC max. (Only the H7Ej-NVj-H has a
backlight.)
The terminals for counter input and reset input for AC/DC
multi-voltage input models have basic insulation.
Connect the reset input terminals to a device that does not have
exposed current-carrying parts and has basic insulation for
240 VAC.
H7ET