H7GP-C Omron, H7GP-C Datasheet - Page 3

COUNTER TOTAL LCD 6DIGT 100-240V

H7GP-C

Manufacturer Part Number
H7GP-C
Description
COUNTER TOTAL LCD 6DIGT 100-240V
Manufacturer
Omron
Datasheets

Specifications of H7GP-C

Count Rate
*
Number Of Digits/alpha
*
Input Type
*
Voltage - Supply
*
Display Type
*
Output Type
*
No. Of Digits / Alpha
6
Digit Height
8.5mm
Power Consumption
6.5VA
Counting Speed
5kHz
Operating Temperature Range
-10°C To +55°C
Height
24mm
Mounting Type
Panel
Supply Voltage Min
100VAC
Color
Gray
Connector Type
Screw Terminals
Counter Supply Voltage
100-240VAC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H7GPC
■ Characteristics
Insulation resistance
Dielectric strength
Impulse withstand voltage 3 kV (between power terminals) (1 kV for 12-to-24-VDC models)
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
EMC
Approved standards
Case color
Weight
http://www.ia.omron.com/
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current-carrying metal parts
(AC model)
1,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current-carrying metal parts
(DC model)
2,000 VAC, 50/60 Hz for 1 min between power terminals and control input terminals (AC model)
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) (1.5 kV for 12-to-24-VDC
models)
±1.5 kV (between AC power terminals), ±480 V (between DC power terminals),
±480 V (between input terminals);
square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Display:
DIP switch: Malfunction:4 kV
Destruction: 10 to 55 Hz with 0.75-mm single amplitude, four cycles each in three directions (8 minutes per cycle)
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude, four cycles each in three directions (8 minutes per cycle)
Destruction: 294 m/s
Malfunction: 196 m/s
Operating: –10°C to 55°C (with no icing)
Storage:
Operating: 35% to 85%
(EMI)
Emission Enclosure:
Emission AC Mains:
(EMS)
Immunity ESD:
Immunity RF-interference:
Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (according to EN61000-6-2)
Immunity Burst:
Immunity Surge:
Immunity Voltage Dip/Interruption: EN61000-4-11: 0.5 cycle, 100% (rated voltage)
UL508, CSA22.2 No.14, conforms to EN61010-1, VDE0106/P100
Rear section: Gray smoke; Front section: 5Y7/1 (light gray) or N1.5 (black)
Approx. 75 g
–25°C to 65°C (with no icing)
Malfunction:8 kV
Destruction:15 kV
Destruction:8 kV
2
2
each in three directions
each in three directions
EN61326
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61326
EN61000-4-2: 4 kV contact discharge (level 2)
EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3);
EN61000-4-4: 2 kV power-line (level 3);
EN61000-4-5: 1 kV line to lines (power and output lines) (level 2);
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
8 kV air discharge (level 3)
10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3)
2 kV I/O signal-line (level 4)
2 kV line to ground (power and output lines) (level 3)
H7GP
3