H7GP-C Omron, H7GP-C Datasheet - Page 5

COUNTER TOTAL LCD 6DIGT 100-240V

H7GP-C

Manufacturer Part Number
H7GP-C
Description
COUNTER TOTAL LCD 6DIGT 100-240V
Manufacturer
Omron
Datasheets

Specifications of H7GP-C

Count Rate
*
Number Of Digits/alpha
*
Input Type
*
Voltage - Supply
*
Display Type
*
Output Type
*
No. Of Digits / Alpha
6
Digit Height
8.5mm
Power Consumption
6.5VA
Counting Speed
5kHz
Operating Temperature Range
-10°C To +55°C
Height
24mm
Mounting Type
Panel
Supply Voltage Min
100VAC
Color
Gray
Connector Type
Screw Terminals
Counter Supply Voltage
100-240VAC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H7GPC
Operation
■ DIP Switch Settings
Set all DIP switches before mounting the Counter to a control panel.
All switches are set toward the display panel before shipping.
H7GP-C/-CD
■ Operating Modes
Nomenclature
Note: The count value will return to "0" when "999999" is
Display
3 (On right side
from front)
4 (On left side
from front)
Total Counters
Count input
Reset input
999999
Switch
exceeded.
4
2
0
Input mode (note
1)
Counting speed
(note 1)
Item
1
Display side
Terminal side
Display side
Terminal side
Function
NPN
PNP
30 Hz
5 kHz
3
Time Counters
Reset input
Start input
Display
Note: Display values are shown for full scale set to 99999.9 h.
99999.9 h
(see note)
H7GP-T/-TD
Note: 1. When the setting has been changed, turned power off and
3 (On right side
from front)
4 (On left side
from front)
0.0h
The count value will return to "0" when "99999.9" is
exceeded.
1. Reset Key
2. Key Protection Indicator
3. NPN/PNP DIP Switch
4. Counting Speed DIP Switch (H7GP-C)
Switch
2. The decimal point will flash every second when “99999.9 h”
Resets the count value, but will not operate while
the keys are protected.
Lit while the keys are protected. (Reset Key is
disabled.).
(Count or start with reset)
When the setting has been changed, turned power
off and on to continue. The display will show "0"
when the power is turned back on. See below for
details.
Time Range DIP Switch (H7GP-T)
When the setting has been changed, turned power
off and on to continue. The display will show "0"
when the power is turned back on. Refer to DIP
Switch Setting for details.
on to continue. The display will show “0” when the power is
turned back on.
is set.
Input mode
(note 1)
Time range
(note 1)
Item
Display side
Terminal side
Display side
Terminal side
Function
NPN
PNP
99999.9h
(note 2)
99 h 59 min
59 s
H7GP
5