H7GP-TB Omron, H7GP-TB Datasheet - Page 3

COUNTER TIME LCD 6DIGT 100-240V

H7GP-TB

Manufacturer Part Number
H7GP-TB
Description
COUNTER TIME LCD 6DIGT 100-240V
Manufacturer
Omron
Type
Time Totalizerr
Datasheets

Specifications of H7GP-TB

Operating Mode
Accumulative
Output Type
*
Voltage - Supply
*
Termination Style
Screw Terminal
Display Type
*
Input Type
*
Number Of Digits/alpha
*
Count Rate
*
Voltage Rating
100 V to 240 V
Mounting
Panel
Counting Method
Accumulative
Size
80 mm L x 44 mm W x 22 mm H
Features
NEMA 4 protection using Y92S-32 rubber gasket supplied with unit, NPN and PNP operations
Time Range
99999.9hr
Power Consumption
6.5VA
Reset Time
20ms
Character Size
8.5mm
Height
24mm
Mounting Type
Panel
Supply Voltage Min
100VAC
Color
Black
Connector Type
Screw Terminals
Width
48mm
Depth
80mm
No. Of Digits / Alpha
6
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H7GPTB
Nomenclature
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Approved standards
Case color
Weight
H7GP
CHARACTERISTICS
y
Display
DIP switch
p y
Malfunction
Destruction
Malfunction
Destruction
Malfunction
Destruction
Malfunction
Destruction
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed
non-current-carrying metal parts (AC model)
1,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed
non-current-carrying metal parts (DC model)
2,000 VAC, 50/60 Hz for 1 min between power terminals and control input terminals
(AC model)
3 kV (between power terminals) (1 kV for 12-to-24-VDC models)
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal
parts) (1.5 kV for 12-to-24-VDC models)
±1.5 kV (between AC power terminals), ±480 V (between DC power terminals),
±480 V (between input terminals);
square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
8 kV
15 kV
4 kV
8 kV
10 to 55 Hz with 0.5-mm single amplitude each in three directions
10 to 55 Hz with 0.75-mm single amplitude each in three directions
196 m/s
294 m/s
Operating: - -10 to 55°C (14 to 131°F) with no icing
Storage:
Operating: 35% to 85%
UL508, CSA22.2 No.14
Rear section: Gray smoke; Front section: 5Y7/1 (light gray) or N1.5 (black)
Approx. 76 g (2.68 0z)
2
2
(20G) each in three directions
(30G) each in three directions
- -25 to 65°C (- -13 to 149°F) with no icing
3
1. Reset Key
2. Key Protection Indicator
3. NPN/PNP DIP Switch
4. Counting Speed DIP Switch (H7GP-C)
Resets the count value, but will not operate while
the keys are protected.
Lit while the keys are protected.
(Count or start with reset)
When setting is changed, cycle power to continue.
Display reads “0” when power is applied.
Time Range DIP Switch (H7GP-T)
When setting is changed, cycle power to continue.
Display reads “0” when power is applied. Refer to
DIP switch settings for details.
H7GP