H7HP-C8 Omron, H7HP-C8 Datasheet
![COUNTER TOTAL 8DIGT 100-240V](/photos/29/87/298748/h7hp_series_sml.jpg)
H7HP-C8
Specifications of H7HP-C8
H7HP-C8 Summary of contents
Page 1
... VAC H7HP VDC H7HP-AD http://www.ia.omron.com/ 3. Supply Voltage None: 100 to 240 VAC VDC 4. Case Color None: Light gray (Munsell 5Y7/1) B: Black Black Light gray H7HP-AB H7HP-C8 H7HP-ADB H7HP-C8D (c)Copyright OMRON Corporation 2007 All Rights Reserved. 8-digit total counter Black H7HP-C8B H7HP-C8DB 1 ...
Page 2
... Total counter Up/down (individual) –9999999 to 99999999 --- --- 1 kΩ max. 100 kΩ min. 1 kΩ max VDC 5 VDC max. 100 kΩ max. 1 kΩ max. 100 kΩ min. Approx (c)Copyright OMRON Corporation 2007 All Rights Reserved. H7HP 8-digit total counter H7HP-C8 H7HP-C8D --- 2 ...
Page 3
... EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3); 10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3) EN61000-4- power-line (level 3 I/O signal-line (level 4) EN61000-4- line to lines (power and output lines) (level 2 line to ground (power and output lines) (level 3) (c)Copyright OMRON Corporation 2007 All Rights Reserved. H7HP 3 ...
Page 4
... H7HP-C8D VDC Power 0 V supply Key protection input NPN mode PNP mode H7HP-C8/-C8D Pin no. 1 Unused 2 Counting speed (note) 3 Input mode (note) NPN ON 4 Unused Time counter Note: When the setting has been changed, turned power off and on 5 kHz to continue. The display will show “ ...
Page 5
... Display 0.0 h Note: 1. Display values are shown for full scale set to 99999.9 h. The count value will return to "0" when "99999.9" is exceeded. 2. Gate input is available only when H7HP-A settings are made. Nomenclature Reset Key Resets the count value, but will not operate while the keys are protected. ...
Page 6
... Dimensions Note: All units are in millimeters unless otherwise indicated. H7HP-A H7HP-C8 Panel Cutouts Panel cutouts are as shown below (according to DIN43700). With Flush Mounting Bracket http://www.ia.omron.com/ M3.5 terminal screw Terminal cover (provided) Note: 1. The mounting panel thickness should mm. 2. Water resistance will be lost if Counters are mounted side-by-side ...
Page 7
... Connections (Common) ■ Input Connections Note: The undermentioned is common for all H7GP/H7HP models. No-voltage Input (NPN Input Mode) Reset, Count 1, Count 2, Start, and Gate Inputs Open Collector Output Voltage Output H7GP/H7HP 12 VDC ( VDC) Sensor Sensor Reset input Count 1 input Count 2 input ...
Page 8
... Use the H7GP/H7HP within the specified ratings for operating temperature and humidity. • Do not operate the H7GP/H7HP in locations subject to sudden or extreme changes in temperature, or locations where high humidity may result in condensation. • Do not use the H7GP/H7HP in locations subject to vibrations or shock ...
Page 9
... Press RST Key or turn power OFF and then ON e2 Memory Labels Unit labels are included with the H7GP/H7HP and DIP switch labels are included with the H7HP. Attach these labels as shown in the following illustrations. Unit Labels H7GP H7HP DIP Switch Labels H7HP ALL DIMENSIONS SHOWN ARE IN MILLIMETERS ...
Page 10
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...