PAXLC600 Red Lion Controls, PAXLC600 Datasheet - Page 3

COUNTER 6-DIGIT BI-DIR COUNT

PAXLC600

Manufacturer Part Number
PAXLC600
Description
COUNTER 6-DIGIT BI-DIR COUNT
Manufacturer
Red Lion Controls
Series
PAX®LITEr
Type
Counterr
Datasheets

Specifications of PAXLC600

Count Rate
25kHz
Number Of Digits/alpha
6
Input Type
Voltage
Voltage - Supply
10 V ~ 16 VDC,115 VAC, 230 VAC
Display Type
LED Red
No. Of Digits / Alpha
6
Digit Height
14.2mm
Power Consumption
6VA
Operating Temperature Range
0°C To +60°C
Signal Input Type
Pulse
Character Size
0.56"
Ip/nema Rating
IP65 / NEMA 4X
Connection Type
Cage-Clamp
Cut Out, Panel
3.62×1.77 "
Dimensions
4.2"L×3.8"W×1.95"H
Display Digit Height
0.56 "
Function
Counter
Number Of Digits
6
Primary Type
Electronic
Range, Measurement
-99999 to 999999
Special Features
Programmable
Termination
Terminal Block
Voltage, Supply
115/230 VAC, 10 to 16 VDC
Counter Supply Voltage
115/230VAC/10-16VDC
Display Font Color
Red
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
RLC101
1. DISPLAY: 6-digit, 0.56" (14.2 mm) or 8-digit, 0.4" (10.1 mm)
2. POWER:
3. SENSOR POWER: 9 to 17.5 VDC @ 100 mA max.
4. KEYPAD: 3 programming keys, the  (Down Arrow) key can also function
5. COUNT INPUT: (DIP switch selectable)
6. MAXIMUM COUNT RATE: 25 KHz max.
7. CONTROL INPUTS:
8. MEMORY: Nonvolatile E
9. ENVIRONMENTAL CONDITIONS:
10. CERTIFICATIONS AND COMPLIANCES:
Installation
The unit is intended to be mounted into an enclosed panel. Prepare the panel
cutout to the dimensions shown. Remove the panel latch from the unit. Slide the
panel gasket over the rear of the unit to the back of the bezel. The unit should
G
BEZEL
1.0 I
Display Range: 6-digit, -99999 to 999999 or 8-digit, -9999999 to 99999999
AC Power: 115/230 VAC, switch selectable. Allowable power line variation
DC Power: 10 to 16 VDC @ 0.1 A max.
as the front panel reset button
Logic State: Active Low
Current Sinking: Internal 7.8 K pull-up to +12 VDC, I max = 1.9 mA
Current Sourcing: Internal 3.9 K pull-down, 8 mA max. @ 30 VDC max.
Filter: Damping capacitor provided for switch contact bounce. Limits input
Count Up/Down Control, Remote Reset, Inhibit, and Store
Max. Continuous Input: 30 VDC
Isolation To Sensor Input Commons: Not isolated
Logic State: Active Low, 22 K pull-up to +12 V
Response Time:
count values.
Operating Temperature Range: 0 to 60°C
Storage Temperature Range: -40 to 60°C
Operating and Storage Humidity: 0 to 85% max. relative humidity
Vibration According to IEC 68-2-6: Operational 5 to 150 Hz, in X, Y, Z
Shock According to IEC 68-2-27: Operational 30 g's, 11 msec in 3
Altitude: Up to 2000 meters
SAFETY
UL Recognized Component, File # E179259, UL61010A-1, CSA C22.2 No. 61010-1
The PAX Lite meets NEMA 4X/IP65 requirements when properly installed.
7-segment red LED
Display Overflow indicated by flashing dot to the right of digit 1
Decimal points are programmed by front panel keys
±10%, 50/60 Hz, 6 VA.
Isolation: 2300 Vrms for 1 min. to input and DC Out/In.
Accepts pulses from a variety of sources including switch contacts, NPN-
OC and TTL Outputs, as well as most standard Red Lion
Input trigger levels V
frequency to 50 Hz and input pulse widths to 10 msec. minimum.
Up/Down and Inhibit: 25 sec max.
Reset and Store: 10 msec. max.
non-condensing
direction for 1.5 hours, 2 g’s.
directions.
Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.
Active: V
ENERAL
Inactive: V
PANEL
GASKET
IN
LATCHING
SLOTS
IN
< 0.9 VDC
NSTALLING THE
> 3.6 VDC
IL
= 1.5 V max.; V
2
PROM retains all programmable parameters and
M
be installed fully assembled. Insert the unit into
PANEL
the panel cutout.
ETER
the panel latch over the rear of the unit
While holding the unit in place, push
so that the tabs of the panel latch
engage in the slots on the case. The
PANEL
MOUNTING
SCREWS
IH
= 3.75 V min.
PANEL
LATCH
S
LATCHING
TABS
PECIFICATIONS
panel latch should
®
be engaged in
sensors
the
forward slot
latch screws
possible. To
tighten the
M
achieve
proper seal,
farthest
ETER
a
3
11. CONNECTIONS: High compression cage-clamp terminal block
12. CONSTRUCTION: This unit is rated for NEMA 4X/IP65 outdoor use.
13. WEIGHT: 12 oz. (340 g)
evenly until the unit is snug in the panel (Torque to approximately 7 in-lbs [79N-
cm]). Do not over-tighten the screws.
Installation Environment
operating temperature and provides good air circulation. Placing the unit near
devices that generate excessive heat should be avoided.
Do NOT use solvents. Continuous exposure to direct sunlight may accelerate the
aging process of the bezel.
keypad of the unit.
ELECTROMAGNETIC COMPATIBILITY
Emissions and Immunity to EN 61326: Electrical Equipment for Measurement,
Notes:
Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 4.5 inch-lbs (0.51 N-m) max.
IP20 Touch safe. Installation Category II, Pollution Degree 2. One piece
bezel/case. Flame resistant. Synthetic rubber keypad. Panel gasket and
mounting clip included.
The unit should be installed in a location that does not exceed the maximum
The bezel should be cleaned only with a soft cloth and neutral soap product.
Do not use tools of any kind (screwdrivers, pens, pencils, etc.) to operate the
Immunity to Industrial Locations:
Electrostatic discharge
Electromagnetic RF fields
Fast transients (burst)
Surge
RF conducted interference
Power frequency magnetic fields
Voltage dip/interruptions
Emissions:
Emissions
UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95
IECEE CB Scheme Test Report # 04ME11209-20041018
Control and Laboratory use.
1. Criterion A: Normal operation within specified limits.
2. EMI filter placed on the DC power supply, when DC powered: Corcom
LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards
Type 4X Enclosure rating (Face only), UL50
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment
IP65 Enclosure rating (Face only), IEC 529
IP20 Enclosure rating (Rear of unit), IEC 529
#1VB3 or Schaffner #FN610-1/07 (RLC #LFIL0000).
Issued by Underwriters Laboratories, Inc.
for measurement, control, and laboratory use, Part 1.
3.62
(92
PANEL CUT-OUT
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
EN 55011
+.03
+.8
-.00
-.0
)
1.77
(45
Criterion A
4 kV contact discharge
8 kV air discharge
Criterion A
10 V/m
Criterion A
2 kV power
2 kV signal
Criterion A
1 kV L-L,
1 kV signal
Criterion A
3 V/rms
Criterion A
30 A/m
Criterion A
0.5 cycle
Class B
2 kV L&N-E power
+.02
+.5
-.00
-.0
)
2
2