LD2006P0 Red Lion Controls, LD2006P0 Datasheet - Page 10

COUNTER 6 DIGIT DUAL 2.25" RED

LD2006P0

Manufacturer Part Number
LD2006P0
Description
COUNTER 6 DIGIT DUAL 2.25" RED
Manufacturer
Red Lion Controls
Series
LDr
Type
Counterr
Datasheets

Specifications of LD2006P0

Count Rate
35kHz
Number Of Digits/alpha
6
Input Type
Voltage, Switch Closure, Transistor Switch
Output Type
Relay and RS232/RS485
Voltage - Supply
11 V ~ 16 VDC, 85 V ~ 250 VAC
Display Type
LED Red
No. Of Digits / Alpha
6
Digit Height
57mm
Power Consumption
26VA
Counting Speed
25kHz
Operating Temperature Range
0°C To +50°C
Signal Input Type
Pulse
Ip/nema Rating
IP65 / NEMA 4X
Accuracy
±0.01% %
Connection Type
Wire Leads
Dimensions
16"L×2.25"W×4"H
Display Digit Height
2.25 "
Function
Counter
Material, Casing
Aluminum
Number Of Digits
6
Primary Type
Electronic
Range, Measurement
0 to 99999
Special Features
RS485/RS232 Communications
Termination
Terminal Block
Voltage, Supply
85 to 250/11 to 16 VAC/VDC
Counter Supply Voltage
85-250VAC/11-16VDC
Display Font Color
Red
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
displays.
shaded selections are only active when Counter B is enabled (Dual Count Mode
or batch counter).
enabled displays. The scroll rate is about every 4 seconds.
or brighten as levels are changed.
INPUT FREQUENCY CALCULATION
edges received during a sample period of time. The sample period begins on the
first falling edge. At this falling edge, the meter starts accumulating time
towards Low Update and High Update values. Also, the meter starts
accumulating the number of falling edges. When the time reaches the Low
Update Time value, the meter looks for one more falling edge to end the sample
period. If a falling edge occurs (before the High Update Time value is reached),
the Rate display will update to the new value and the next sample period will
start on the same edge. If the High Update Time value is reached (without
receiving a falling edge after reaching Low Update Time), then the sample
period will end but the Rate display will be forced to zero. The High Update
Time value must be greater than the Low Update Time value. Both values must
be greater than 0.0. The input frequency calculated during the sample period, is
then shown as a Rate value determined by the scaling calculation.




5.3 MODULE 3 - D
The
The
The
Enter the desired Display Intensity Level (1-5). The display will actively dim
The meter determines the input frequency by summing the number of falling
FRONT PANEL COUNTER RESET ENABLE (RST)
FRONT PANEL DISPLAY SELECT ENABLE (SEL)



selection allows the


selection allows the display to automatically scroll through the
selection allows the

DISPLAY INTENSITY LEVEL
DISPLAY SCROLL ENABLE
Display Select
Front Panel
PAR
3-dSP




SEL-En

Enable
RST
to

SEL
key to reset the selected counter(s). The





key to toggle through the enabled
Reset Enable
Front Panel
rSt-En
Counter
ISPLAY AND


ScroLL
PARAMETER MENU
Display
Enable
Scroll
10
F
d-LEV
Intensity
Display
RONT
Level
of programming parameters. This code can be used along with the Program
Mode Lock-out (
unit parameters to be viewed and modified. Quick Programming mode permits
only user selected values to be modified, but allows direct access to these values
without having to enter Full Programming mode.
displays a sublist to select which values appear in the Quick Programming
menu. All of the values set to
Programming. The values include Setpoints (
(
at the
Programming mode, if enabled, is accessed before the

* Entering Code 222 allows access regardless of security code.
USER INPUT

FUNCTION


The Security Code determines the programming mode and the accessibility
Two programming modes are available. Full Programming mode allows all
Entering a Security Code from 1-99 enables Quick Programming mode, and
Programming any Security Code other than 0, requires this code to be entered
P
not
ARAMETERS

,

Programming
P

USER INPUT
Not Active
CodE
prompt in order to access Full Programming mode. Quick
______
Security
STATE
Active
ANEL
Code
PROGRAMMING SECURITY CODE

), Count Load value (
) in the User Input Function parameter (Module 1).
SECURITY
100-999
100-999
CODE
0-999
1-99
1-99
K

0
0
Operations
FCS
to
EY
Factory
Service


(
Programming Lock
MODE WHEN “PAR”
Full Programming
Full Programming
KEY IS PRESSED

Programming
Programming


in the sublist are accessible in Quick

Quick
Quick
Pro
prompt
prompt

) and Display Intensity (
)
,


After Quick Programming
With correct code entry
With correct code entry
with correct code entry
FULL PROGRAMMING
Immediate Access
Immediate Access
at
at
at
), Output Time-outs
MODE ACCESS
prompt appears.



No Access
No Access
prompt *
prompt *
prompt *

).