H7CX-ASD DC12-24 Omron, H7CX-ASD DC12-24 Datasheet - Page 28

COUNTER SCREW-TERM 6DIGT 1/16DIN

H7CX-ASD DC12-24

Manufacturer Part Number
H7CX-ASD DC12-24
Description
COUNTER SCREW-TERM 6DIGT 1/16DIN
Manufacturer
Omron
Series
H7CXr
Datasheet

Specifications of H7CX-ASD DC12-24

Count Rate
*
Number Of Digits/alpha
6
Input Type
*
Output Type
*
Voltage - Supply
12 V ~ 24 V
Display Type
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CX-ASDDC12-24
H7CXASDDC1224
H7CXASDDC1224Q1
Dual Counter Operation
Using the dual counter allows the count from 2 inputs to be added or subtracted and the result displayed. It is possible to specify a set value for
which output turns ON when the set value matches the added or subtracted result.
OUT1 and OUT2 turn ON and OFF simultaneously.
Note: 1. Counting is not possible for CP1 during reset 1 input. CP2 will not be affected. The dual count value will be calculated based on a CP1
Dual count set value
CP2 present value
CP1 present value
Note: The above is for when the output mode is N.
Dual count value
2. Counting is not possible for CP2 during reset 2 input. CP1 will not be affected. The dual count value will be calculated based on a CP2
3. The counting range for the dual count value is −99,999 to 999,999 (0 to 9,999 for 4-digit models). The counting ranges for the CP1 present
Reset 1
(CP1 reset)
Reset 2
(CP2 reset)
OUT1, 2
Dual Count Calculating Mode = ADD
Dual count value = CP1 PV + CP2 PV
present value of 0.
present value of 0.
value and CP2 present value are 0 to 999,999 (0 to 9,999 for 4-digit models). If a present value exceeds 999,999 (9,999 for 4-digit mod-
els), FFFFFF (FFFF for 4-digit models) will be displayed to indicate an overflow, and all counting will stop.
0
0
0
Dual count set value
CP1 present value
CP2 present value
Dual count value
Note: The above is for when the output mode is
Dual Count Calculating Mode = SUB
Dual count value = CP1 PV − CP2 PV
Reset 1
(CP1 reset)
Reset 2
(CP2 reset)
OUT1, 2
K-2. SUB mode can be used only when
K-2, D, L, or H is selected as the output
mode with 6-digit models.
0
0
0
• The operation after count com-
• The CP1 present value is reset
• If the reset key is pressed while
pletion for the dual counter
value is determined by the out-
put mode.
when reset 1 input is turned
ON and the CP2 present value
is reset when reset 2 input is
turned ON.
the dual count value, CP1
present value, or CP2 present
value is displayed, all of the
present values are reset and
outputs turn OFF. At this time,
counting is not possible for
CP1 or CP2 inputs.
H7CX-A
28