CUB70020 Red Lion Controls, CUB70020 Datasheet - Page 3

COUNTER 8-DIGIT RED BACKLIGHT

CUB70020

Manufacturer Part Number
CUB70020
Description
COUNTER 8-DIGIT RED BACKLIGHT
Manufacturer
Red Lion Controls
Series
CUB7r
Datasheets

Specifications of CUB70020

Count Rate
10kHz
Number Of Digits/alpha
8
Input Type
Voltage, Switch Closure, Transistor Switch
Voltage - Supply
9 V ~ 28 V
Display Type
LCD Backlit
No. Of Digits / Alpha
8
Digit Height
8.9mm
Supply Voltage Range
9V DC To 28V DC
Operating Temperature Range
0°C To +50°C
Bezel Height
28mm
Bezel Width
51mm
Character Size
9mm
Character Type
7
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
Other names
RLC702
EMC INSTALLATION GUIDELINES
ElectroMagnetic Interference (EMI), proper installation and wiring methods
must be followed to ensure compatibility in each application. The type of the
electrical noise, source or coupling method into the unit may be different for
various installations. In extremely high EMI environments, additional measures
may be needed. The unit becomes more immune to EMI with fewer I/O
connections. Cable length, routing and shield termination are very important
and can mean the difference between a successful installation or a troublesome
installation. Listed below are some EMC guidelines for successful installation
in an industrial environment.
1. Use shielded (screened) cables for all Signal and Control inputs. The shield
2. Never run Signal or Control cables in the same conduit or raceway with AC
WIRING CONNECTIONS
the back of the unit. All conductors should meet voltage and current ratings for
each terminal. Also cabling should conform to appropriate standards of good
installation, local codes and regulations. It is recommended that power supplied
to the unit (AC or DC) be protected by a fuse or circuit breaker. When wiring
the unit, use the battery cover to identify the wire position with the proper
function. Strip the wire, leaving approximately 1/4" bare wire exposed
(stranded wires should be tinned with solder). Insert the wire under the screw-
clamp and tighten down the screw until the wire is clamped in tightly. Each
terminal can accept up to two #14 AWG wires.
Backlight Wiring
VDC power supply. The external supply is connected between the V+ and
Common terminals.
INSTALLATION ENVIRONMENT
operating temperature and provides good air circulation. Placing the unit near
devices that generate excessive heat should be avoided.
Do NOT use solvents.
the bezel.
the keypad of the unit.
Installation
indoor use, when properly installed. The units are intended to be mounted into
an enclosed panel. The viewing window and reset button are factory sealed for
a washdown environment. A sponge rubber gasket and mounting clip are
provided for installing the unit in the panel cut-out.
1. Cut panel opening to specified dimensions. Remove burrs and clean around
2. Carefully remove and discard the center section of the gasket. Slide the
3. Install CUB7 unit through the panel cut-out until front bezel flange contacts
4. Slide the mounting clip over the rear of the unit until the clip is against the
Although this unit is designed with a high degree of immunity to
(screen) pigtail connection should be made as short as possible. The
connection point for the shield depends somewhat upon the application.
Listed below are the recommended methods of connecting the shield, in order
of their effectiveness.
a. Connect the shield only at the panel where the unit is mounted to earth
b. Connect the shield to earth ground at both ends of the cable, usually when
c. Connect the shield to common of the unit and leave the other end of the
power lines, conductors feeding motors, solenoids, SCR controls, and
heaters, etc. The cables should be run in metal conduit that is properly
grounded. This is especially useful in applications where cable runs are long
The electrical connections are made via screw-clamp terminals located on
Optional backlight versions of the CUB7 series require an external 9-28
The unit should be installed in a location that does not exceed the maximum
The bezel should be cleaned only with a soft cloth and neutral soap product.
Continuous exposure to direct sunlight may accelerate the aging process of
Do not use tools of any kind (screwdrivers, pens, pencils, etc.) to operate
The CUB7 series of products meets NEMA 4X/IP65 requirements for
The following procedure assures proper installation:
panel opening.
panel gasket over the rear of the unit to the back of the bezel. Insert the
mounting screws onto both sides of mounting clip. Tip of screw should
NOT project from hole in mounting clip.
the panel.
back of the panel. The mounting clip has latching features which engage
into mating features on the CUB7 housing.
ground (protective earth).
the noise source frequency is above 1 MHz.
shield unconnected and insulated from earth ground.
3
5. Alternately tighten each screw to ensure uniform gasket pressure.
6. If gasket is not adequately compressed and the mounting screws can no
7. Repeat from step #5 for tightening mounting screws.
3. Signal or Control cables within an enclosure should be routed as far away as
4. In extremely high EMI environments, the use of external EMI suppression
5. Long cable runs are more susceptible to EMI pickup than short cable runs.
Note: It is necessary to hold the unit in place when sliding mounting clip
Visually inspect the front panel gasket. The gasket should be compressed to
about 75 to 80% of its original thickness. If not, gradually turn mounting
screws to further compress gasket.
longer be turned, loosen mounting screws, and check that mounting clip is
latched as close as possible to the panel.
and portable two-way radios are used in close proximity or if the installation
is near a commercial radio transmitter.
possible from contactors, control relays, transformers, and other noisy
components.
devices, such as ferrite suppression cores, is effective. Install them on Signal
and Control cables as close to the unit as possible. Loop the cable through the
core several times or use multiple cores on each cable for additional protection.
Install line filters on the power input cable to the unit to suppress power line
interference. Install them near the power entry point of the enclosure. The
following EMI suppression devices (or equivalent) are recommended:
Ferrite Suppression Cores for signal and control cables:
Line Filters for input power cables:
Note: Reference manufacturer’s instructions when installing a line filter.
Therefore, keep cable runs as short as possible.
into position.
Fair-Rite # 0443167251 (RLC #FCOR0000)
TDK # ZCAT3035-1330A
Steward #28B2029-0A0
Schaffner # FN610-1/07 (RLC #LFIL0000)
Schaffner # FN670-1.8/07
Corcom #1VR3
WARNING: Lithium battery may explode if incinerated. All
leads will be at the same line potential as the input leads.