Specifications of DMU-30ACV-1-DR-C

Display Type
LED
Measuring Range
0 ~ 199.9VAC
Display Style
Red Characters, Black Background
Display Digits
3.5
Display Digits - Height
0.560" (14.22mm)
Backlight
Without
Mounting Type
Panel Mount
Termination
Terminal Block
Voltage - Supply
85 ~ 264VAC
Equipment Type
AC Voltmeter
Input
199.9 mV
Dimensions
72.39 mm L x 40.64 mm W x 44.7 mm H
Mounting Style
Panel
Primary Voltage Rating
85 V to 264 V
Secondary Voltage Rating
110 VDC to 300 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Display Face Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
811-1940

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DMU-30ACV-1-DR-C
Manufacturer:
Murata Power Solutions Inc
Quantity:
135
TECHNICAL NOTES (continued)
4. Calibration: Periodic recalibration of DMU-30ACV voltmeters is
5. Minimum-Intensity Adjustment Potentiometer: Users can adjust
6. 2-Wire Operation: In indoor applications where daylight readability
Ordering Information
Model
DMU-30ACV-0-DR-C
DMU-30ACV-1-DR-C
DMU-30ACV-2-DR-C
not required under most indoor operating environments. However,
units operating in environments subject to vibration and/or extreme
temperature variations should have their accuracy verifi ed on a yearly
basis. If recalibration is necessary, it should only be performed by
qualifi ed technical personnel. Calibration is performed with potentially
lethal voltages applied to the DMU-30ACV and its associated wiring.
A plastic, fully-insulated adjusting tool must be used to access the
recessed potentiometers located on the back of the unit (see Mechani-
cal Specifi cations). Contact Murata / DATEL if additional information
is required regarding calibration, setup, or any other technical issue
pertaining to DMU-30ACV ac voltmeters.
the DMU-30ACV’s minimum LED display brightness to suit their indoor
viewing requirements by adjusting the ¾-turn, rear-mounted intensity
adjustment potentiometer. Please note, this potentiometer will have
minimal impact on display brightness in high ambient light environ-
ments.
The intensity adjustment potentiometer is factory preset to its mid-
point position. As viewed from the rear of the meter, and with the
model number label facing up, turning the potentiometer clockwise
increases the LED display’s intensity. See the Mechanical Specifi ca-
tions section for potentiometer locations.
(i.e., maximum display brightness) is not required, DMU-30ACV meters
will meet their specifi ed accuracy with ac supply voltages (TB1) well
below 85Vac. While performance is not guaranteed, DMU-30ACV
voltmeters’ remain easily readable and accurate with ac supplies as
low as 20Vac in most indoor environments.
Please note, when operated indoors in a 2-wire mode (i.e., TB1 and
TB2 are connected to the same ac voltage), DMU-30ACV series’ input
current will increase as the input supply is decreased. At 20Vac, the
input supply current will be approximately 30mA.
Input Range
0 to 19.99Vac
0 to 199.9Vac
0 to 300Vac
www.murata-ps.com/dpm
Performance/Functional Specifi cations
Typical at T
➀ Specifi ed accuracy applies to inputs with crest factors (CF) up to 2.0, where CF = Vpeak/
➁ Display reading is set to “1888”. Specifi ed power supply currents are steady state; larger
Input (TB2)
Full Scale Input Range:
Input-Voltage Frequency Range
Performance
Sampling Rate
Accuracy
Measurement Type
Zero Reading (within 30 sec.)
Temperature Drift (0 to +60°C)
Breakdown Voltage (TB1 to TB2)
Supply Voltage (TB1)
DMU-30ACV
Supply Current (TB1)
DMU-30ACV (total darkness)
DMU-30ACV (full sunlight)
Terminal Block Wiring (TB1 & TB2)
Wire Size
Insulation Strip Length
Screw Tightening Torque
Rated Voltage
Display
Display Type and Size
Decimal Point
Overrange Indication
Physical/Environmental
Operating Temperature
Storage Temperature
Humidity (non-condensing)
Dimensions
Weight
Ruggedized True-rms ac Voltmeters with Daylight
DMU-30ACV-0
DMU-30ACV-1
DMU-30ACV-2
Vrms. Crest factors of 2-5 introduce an additional eror of ±3% of full scale. Voltmeters
are calibrated with near full-scale, 60Hz sine-wave input.
surge currents can occur at initial application of ac power. Power supply input (TB1) set to
120Vac/60 Hz.
A
= +25°C, 60Hz sine-wave input, unless otherwise noted.
Readable, Auto-Dimming LED Displays
DMU-30ACV Series
24 Mar 2011 MPM_DMU-30ACV.B07 Page 2 of 3
“–002”
3½ digit, 0.56"/14.2mm high red LED
RMS responding, Crest Factors of 1-5
Min.
2000
–25
–40
47
Daylight readable, auto-dimming,
0
0
0
0
85
1.3 ounces (36 grams) nominal
See mechanical specifi cations
±0.4%FS ±2 counts w/ 60Hz
16-22 AWG, Solid or stranded
email: sales@murata-ps.com
3.6 pound-inches (0.4Nm)
2.5 readings per second
Fixed, model dependent
0.250 inches (6.35)
“000”
Typ.
sine-wave input
±0.2
60
40
4
"1_ _ _ "
300Vac
Max.
19.99
199.9
“002”
1000
±0.4
+60
+75
300
264
85
50
6
Vac/47-
63Hz
mA/47-
63Hz
mA/47-
63Hz
Cnts/°C
Units
Cnts
Vac
Vac
Vac
Vdc
Hz
°C
°C
%