K3HB-RNB 100-240VAC Omron, K3HB-RNB 100-240VAC Datasheet - Page 14

ROTARY PULSE INDICATR NPN/V INPT

K3HB-RNB 100-240VAC

Manufacturer Part Number
K3HB-RNB 100-240VAC
Description
ROTARY PULSE INDICATR NPN/V INPT
Manufacturer
Omron
Series
K3HBr
Type
Pulse Meterr
Datasheet

Specifications of K3HB-RNB 100-240VAC

Measuring Range
0 ~ 50kHz
Display Style
Green, Red Characters, Black Background
Display Type
LCD
Display Face Size
3.78" L x 1.89" W (96.0 x 48.0mm)
Display Digits
5
Display Digits - Height
0.193" (4.90mm), 0.559" (14.20mm)
Backlight
Green, Red
Mounting Type
Panel Mount
Termination
Screw Terminals
Voltage - Supply
100 ~ 240VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
K3HB-RNB100-240VAC
K3HBRNB100240VAC
■ What Is Prescaling?
To make calculations using the input pulse to display the passing speed between two points, the distance between the two points and the display
unit must be set and the internally measured time multiplied by a certain coefficient. This coefficient is called the prescale value. (For information
on settings details, refer to the User's Manual.)
Time Unit Settings
14
F4
Time band
F5
Measuring
length
F6
Interval
scal
min
h.mm.ss
mm.ss.d
Function
Setting
Displays input A ON time (T).
• Recovery time (TR) of 20 ms is required before
æ
ç
ç
è
Displays the number of input A pulses while input B is
ON.
• Recovery time (TR) of 20 ms is required before
æ
ç
è
Displays the number of input A pulses from when input
B turns ON until input B turns ON again. Measurement
is made every other time input B turns ON.
• Recovery time (TR) of 20 ms is required before
æ
ç
è
Input A
Input B
HOLD input
Display
Timer Interval Indicator
Input A
Input B
HOLD input
Display
HOLD input
Input A
Display
starting the next measurement.
starting the next measurement.
starting the next measurement.
Display unit:
Display unit:
Display unit:
ms, s, min.,
min.s.1/10 s
mm, cm, m, etc.
mm, cm, m, etc.
Measurement range: 10 ms to 3,200 s
Prescale value menu setting
Minute display
h.mm.ss display
mm.ss.d display (d = tenths of a second)
1 2 3 4
1 2 3 4 5
T
1
ö
÷
÷
ø
T
T
R
R
ö
÷
ø
ö
÷
ø
Operation
3
6
1 2 3 4
T
2
Meaning
K3HB-P
T
T
R
1
T
R
6
4
1 2 3 4 5
T
1
3
2
T
3
5
1
Measuring workpiece length
Measuring slit intervals
Monitoring the ON time of a printing
press
Input Type Setting
Note: Set to 10 or 11 when there is a large variation in the display.
No-contact or
voltage pulse
input
Contact
The largest measurement range is 30 Hz.
Operation image (application)
NO: Voltage pulse high NC: Voltage pulse low
00
10
Display
INA
INB
BCD
1 2
Managing the valve release
time
To Programmable Controller
3
OK judgment
01
11
T
R
H
PASS
L
3
1 2
T
R
2
Communications
output
1 2