K3HB-VLC 24VAC/VDC Omron, K3HB-VLC 24VAC/VDC Datasheet - Page 8

no-image

K3HB-VLC 24VAC/VDC

Manufacturer Part Number
K3HB-VLC 24VAC/VDC
Description
WEIGHING INDICATR DC VOLTAG INPT
Manufacturer
Omron
Series
K3HBr
Type
Weighing Meterr
Datasheet

Specifications of K3HB-VLC 24VAC/VDC

Measuring Range
0 ~ 199.9mV
Display Style
Green, Red Characters, Black Background
Display Type
LCD
Display Face Size
3.78" L x 1.89" W (96.0 x 48.0mm)
Display Digits
5
Display Digits - Height
0.193" (4.90mm), 0.559" (14.20mm)
Backlight
Green, Red
Mounting Type
Panel Mount
Termination
Screw Terminals
Voltage - Supply
24VAC/DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
K3HB-VLC24VAC/VDC
K3HBVLC24VACVDC
■ Input Range (Measurement Range and Accuracy) CAT II
Note: 1. The accuracy is for an input frequency range of 40 Hz to 1 kHz (except for AD current input A and B ranges) and an ambient temperature
K3HB-XVD
DC voltage
K3HB-XAD
DC current
K3HB-XVA
AC voltage
K3HB-XAA
AC current
Input type
2. The letters “rdg” mean “reading” and refer to the input error.
3. The value (0.5 VA CT) is the VA consumption of the internal CT (current transformer).
of 23 ±5°C. The error, however, increases below 10% of the maximum input value.
DC voltage input (all ranges): 10% or less of max. input = ±0.15% FS
DC current input (all ranges): 10% or less of max. input = ±0.1% FS
AC voltage input (A: 0.0 to 400.0 V): 10% or less of max. input = ±0.15% FS
AC voltage input (B: 0.00 to 199.99 V): 10% or less of max. input = ±0.2% FS
AC voltage input (C: 0.000 to 19.999 V; D: 0.0000 to 1.9999 V): 10% or less of max. input = ±1.0% FS
AC current input (A: 0.000 to 10.000 A): 10% or less of max. input = ±0.25% FS
AC current input (B: 0.0000 to 1.9999 A): 10% or less of max. input = ±0.5% FS
AC current input, (C: 0.00 to 199.99 mA; D: 0.000 to 19.999 A): 10% or less of max. input = ±0.15% FS
When DC voltage input models are used with a ±1.9999 V range, make sure that the connections between input terminals are not open.
If the input terminals are open, the display will show large variations. Connect resistance of approximately 1 MΩ between the input ter-
minals if they are open.
A
B
C
D
A
B
C
D
A
B
C
D
A
B
C
D
±1.9999 V
+
Range
1 MΩ
E2
E3
E4
E5
E6
COM
a Ud
b Ud
c Ud
d Ud
a ad
b ad
c ad
d ad
a Ua
b Ua
c Ua
d Ua
a aa
b aa
c aa
d aa
Set value
±199.99 V
±19.999 V
±1.9999 V
1.0000 to 5.0000 V
±199.99 mA
±19.999 mA
±1.9999 mA
4.000 to 20.000 mA
0.0 to 400.0 V
0.00 to 199.99 V
0.000 to 19.999 V
0.0000 to 1.9999 V
0.000 to 10.000 A
0.0000 to 1.9999 A
0.00 to 199.99 mA
0.000 to 19.999 mA
Measurement range
10 MΩ min.
1 MΩ min.
1 Ω max.
10 Ω max.
33 Ω max.
10 Ω max.
1 MΩ min.
(0.5 VA CT)
(See note 3.)
(0.5 VA CT)
(See note 3.)
1 Ω max.
10 Ω max.
Input impedance
Process Indicator
±0.1%rdg ± 1 digit
max.
±0.1%rdg ± 1 digit
max.
±0.3%rdg ± 5 dig-
its max.
±0.5%rdg ± 10
digits max.
±0.5%rdg ± 20
digits max.
±0.5%rdg ± 10
digits max.
(See Note 1 & 2)
Accuracy
K3HB-X
±400 V
±200 V
±400 mA
±200 mA
700 V
400 V
20 A
2 A
overload (30 s)
instantaneous
Allowable
B-15