K3HB-XAD 100-240VAC Omron, K3HB-XAD 100-240VAC Datasheet - Page 7

no-image

K3HB-XAD 100-240VAC

Manufacturer Part Number
K3HB-XAD 100-240VAC
Description
PROCESS INDICATR DC CURRNT INPUT
Manufacturer
Omron
Series
K3HBr
Type
Process Meterr
Datasheet

Specifications of K3HB-XAD 100-240VAC

Measuring Range
0 ~ 199.99mA
Display Style
Green, Red Characters, Black Background
Display Type
LCD
Display Face Size
3.78" L x 1.89" W (96.0 x 48.0mm)
Display Digits
5
Display Digits - Height
0.193" (4.90mm), 0.559" (14.20mm)
Backlight
Green, Red
Mounting Type
Panel Mount
Termination
Screw Terminals
Voltage - Supply
100 ~ 240VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
K3HB-XAD100-240VAC
K3HBXAD100240VAC
■ Characteristics
B-14
Display range
Sampling period
Comparative output response time DC input: 100 ms max.; AC input: 300 ms max.
Linear output response time
Insulation resistance
Dielectric strength
Noise immunity
Vibration resistance
Shock resistance
Weight
Degree of
protection
Memory protection
Applicable standards
EMC
Process Indicator
Front panel
Rear case
Terminals
K3HB-X
−19,999 to 99,999
20 ms (50 times/second)
DC input: 150 ms max.; AC input: 420 ms max.
20 MΩ min. (at 500 VDC)
2,300 VAC for 1 min between external terminals and case
100 to 240 VAC models:
24 VAC/VDC models:
Frequency: 10 to 55 Hz; Acceleration: 50 m/s
150 m/s
Approx. 300 g (Digital Indicator only)
Conforms to NEMA 4X for indoor use (equivalent to IP66)
IP20
IP00 + finger protection (VDE0106/100)
EEPROM (non-volatile memory)
Number of rewrites: 100,000
UL61010C-1, CSA C22.2 No. 1010.1 (approval pending)
EN61010-1 (IEC61010-1): Pollution degree 2/Overvoltage category II
EN61326: 1997, A1: 1998, A2: 2001
EMI: EN61326+A1 industrial applications
Electromagnetic radiation interference
Terminal interference voltage
EMS: EN61326+A1 industrial applications
Electrostatic Discharge Immunity
Radiated Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
Conducted Disturbance Immunity
Voltage Dips and Interruptions Immunity
±1,500 V at power supply terminals in normal or common mode
(waveform with 1-ns rising edge and pulse width of 1 µs/100 ns)
(waveform with 1-ns rising edge and pulse width of 1 µs/100 ns)
CISPR 11 Group 1, Class A: CISPRL16-1/-2
CISPR 11 Group 1, Class A: CISPRL16-1/-2
EN61000-4-2: 4 kV (contact), 8 kV (in air)
EN61000-4-3: 10 V/m 1 kHz sine wave amplitude modulation (80 MHz to 1 GHz)
EN61000-4-4: 2 kV (power line), 1 kV (I/O signal line)
EN61000-4-5: 1 kV with line (power line), 2 kV with ground (power line)
EN61000-4-6: 3 V (0.15 to 80 MHz)
EN61000-4-11: 0.5 cycle, 0°/180°, 100% (rated voltage)
±1,500 V at power supply terminals in normal or common mode
2
(100 m/s
2
for relay outputs) 3 times each in 3 axes, 6 directions
2
, 10 sweeps of 5 min each in X, Y, and Z directions