K3HB-XAD 24VAC/VDC Omron, K3HB-XAD 24VAC/VDC Datasheet - Page 12

PROCESS INDICATR DC CURRNT INPUT

K3HB-XAD 24VAC/VDC

Manufacturer Part Number
K3HB-XAD 24VAC/VDC
Description
PROCESS INDICATR DC CURRNT INPUT
Manufacturer
Omron
Series
K3HBr
Type
Process Meterr
Datasheets

Specifications of K3HB-XAD 24VAC/VDC

Measuring Range
0 ~ 199.99mA
Display Style
Green, Red Characters, Black Background
Display Type
LCD
Display Face Size
3.78" L x 1.89" W (96.0 x 48.0mm)
Display Digits
5
Display Digits - Height
0.193" (4.90mm), 0.559" (14.20mm)
Backlight
Green, Red
Mounting Type
Panel Mount
Termination
Screw Terminals
Voltage - Supply
24VAC/DC
Analog / Digital
Digital
Control Method
ON/OFF
Voltage Rating
24 V
Mounting
Panel
Size
95 mm L x 96 mm W x 44.8 mm H
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
K3HB-XAD24VAC/VDC
K3HBXAD24VACVDC
■ Main Functions
Measurement
Normal
• Continuously performs measurement and always outputs based on
Peak Hold/Bottom Hold
• Measures the maximum (or minimum) value in a specified period.
Scaling converts input signals in any way required before displaying
them. The values can be manipulated by shifting, inverting, or +/–
reversing.
Settings for scaling can be made using the present measurement
values instead of inputting values with the SHIFT and UP Keys. This
is a convenient function for making the settings while monitoring the
operating status.
Turns the comparative output OFF until the measurement value
enters the PASS range.
Display value 2
Display value 1
H comparative set value
Timing Hold
Measurement value
Scaling
Teaching
Standby Sequence
Display value
comparative results.
Measurement value
(dsp.a2)
(dsp.a1)
TIMING
input
OFF
Input
H output
ON
Input value 1
(inp.a1)
Input
(Scaling)
Input value 2
(inp.a2)
Input value
Display value 2
Display value 1
Display value
(dsp.a2)
(dsp.a1)
Input value 2
(inp.a2)
(Reverse scaling)
Peak hold value
Input value 1
Bottom hold value
(inp.a1)
Time
Time
Input value
Sampling Hold
• Holds the measurement at the rising edge of the TIMING signal.
Peak-to-peak Hold
• Measures the difference between the maximum and minimum val-
Average processing of input signals with extreme changes or noise
smooths out the display and makes control stable.
Slight changes can be removed from input signals to detect only
extreme changes.
Average Processing
Previous Average Value Comparison
Measurement value
ues in a specified period.
Measurement value
TIMING
TIMING
input
input
OFF
Input
Input
OFF
ON
ON
a1
b1
(b1−a1)
'a2
'b2
Sampling hold value
K3HB-X
Peak-to-peak value
(b2−a2)
Time
Time
12