PAXLHV00 Red Lion Controls, PAXLHV00 Datasheet - Page 3

METER AC VOLT 3-DIGIT PNL MNT

PAXLHV00

Manufacturer Part Number
PAXLHV00
Description
METER AC VOLT 3-DIGIT PNL MNT
Manufacturer
Red Lion Controls
Series
PAX®LITEr
Type
Voltmeterr
Datasheet

Specifications of PAXLHV00

Measuring Range
0 ~ 600VAC
Display Style
Red Characters, Black Background
Display Type
LED
Display Face Size
3.80" L x 1.95" W (96.5 x 49.5mm)
Display Digits
3
Display Digits - Height
0.560" (14.22mm)
Backlight
Without
Mounting Type
Panel Mount
Termination
Terminal Block
Voltage - Supply
115VAC,230 VAC
No. Of Digits / Alpha
3
Meter Function
AC Voltmeter
Meter Range
0V To 600V
Digit Height
14.2mm
Power Consumption
6VA
Operating Temperature Range
0°C To +60°C
Supply Voltage Ac, Min
115V
Character Size
0.56"
Display Font Color
Red
Rohs Compliant
NA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
RLC111
UNITS LABEL KIT (PAXLBK)
using the Units Label Kit. The backlight is controlled by a DIP switch.
1. DISPLAY: 3-digit, 0.56" (14.2 mm) high character, 7-segment Red LED
2. POWER: 115 or 230 VAC, switch selectable. Allowable power line variation
3. ACCURACY: At 23°C, 85% R.H.; ±(0.1% of Reading + 2 digits)
4. INPUT IMPEDANCE: 1 M
5. INPUT RANGE: 0 to 600 VAC max. @ 45 to 500 Hz. Installation Category I
6. RESOLUTION: 1 VAC
7. ENVIRONMENTAL CONDITIONS:
8. READING RATE: 400 msec., nominal
9. RESPONSE TIME: 1 sec. nominal for a step change input.
10. CERTIFICATIONS AND COMPLIANCES:
G
A
Each meter has a units indicator with backlighting that can be customized
±10%, 50/60 Hz, 6 VA. Installation Category II, Pollution Degree 2.
Isolation: 2300 Vrms for 1 min. to input
Working Voltage: 300 V max., CAT II
Operating Temperature Range: 0° to 60°C
Storage Temperature Range: -40° to 80°C
Operating and Storage Humidity: 85% max. relative humidity (non-
Temperature Coefficient: ±150 PPM/°C
Vibration According to IEC 68-2-6: Operational 5 to 150 Hz, in X, Y, Z
Shock According to IEC 68-2-27: Operational 30 g’s, 11 msec in 3 directions.
Altitude: Up to 2000 meters
SAFETY
UL Recognized Component, File #E179259, UL61010A-1, CSA C22.2 No. 61010-1
UL Listed, File #E137808, UL508, CSA C22.2 No. 14-M95
IECEE CB Scheme Test Report #04ME11209-20041018
condensing)
direction for 1.5 hours, 2 g’s.
Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories Inc.
LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards
Type 4X Enclosure rating (Face only), UL50
Issued by Underwriters Laboratories, Inc.
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment
IP65 Enclosure rating (Face only), IEC 529
CCESSORIES
ENERAL
for measurement, control, and laboratory use, Part 1.
M
ETER
S
PECIFICATIONS
3
Notes:
11. CONNECTIONS: High compression cage-clamp terminal block
12. CONSTRUCTION: This unit is rated for NEMA 4X/IP65 outdoor use.
13. WEIGHT: 0.65 lbs. (0.24 Kg)
ELECTROMAGNETIC COMPATIBILITY:
Emissions and Immunity to EN 61326: Electrical Equipment for
Measurement, Control and Laboratory use.
1. Criterion A: Normal operation within specified limits.
2. Criterion B: Temporary loss of performance from which the unit self-
Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 4.5 inch-lbs (0.51 N-m) max.
Installation Category II, Pollution Degree 2. One piece bezel/case. Flame
resistant. Panel Gasket and mounting clip included.
Immunity to Industrial Locations:
Electrostatic discharge
Electromagnetic RF fields
Fast transients (burst)
Surge
RF conducted interference
Voltage dip/interruptions
Emissions:
Emissions
recovers.
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-11
EN 55011
Criterion A
4 kV contact discharge
8 kV air discharge
Criterion B
10 V/m
Criterion A
2 kV power
2 kV signal
Criterion A
1 kV L-L,
2 kV L&N-E power
Criterion A
3 V/rms
Criterion A
0.5 cycle; 40 % variation
Class B