PAXLPV00 Red Lion Controls, PAXLPV00 Datasheet - Page 3

METER PROCESS VOLT 3 1/2-DIGIT

PAXLPV00

Manufacturer Part Number
PAXLPV00
Description
METER PROCESS VOLT 3 1/2-DIGIT
Manufacturer
Red Lion Controls
Series
PAX®LITEr
Type
Voltmeterr
Datasheets

Specifications of PAXLPV00

Measuring Range
0 ~ 25 VDC
Display Style
Red Characters, Black Background
Display Type
LED
Display Face Size
3.80" L x 1.95" W (96.5 x 49.5mm)
Display Digits
3.5
Display Digits - Height
0.560" (14.22mm)
Backlight
Without
Mounting Type
Panel Mount
Termination
Screw Terminals
Voltage - Supply
85 ~ 250VAC
No. Of Digits / Alpha
3-1/2
Meter Function
DC Process
Meter Range
± 0V To ± 25V
Digit Height
14.2mm
Power Consumption
6VA
Operating Temperature Range
0°C To +60°C
Supply Voltage Ac, Min
85V
Accuracy
±0.05% %
Common Mode Rejection Ratio
100 dB
Connection Type
Cage-Clamp
Cut Out, Panel
3.62×1.77 "
Dimensions
4.2"L×3.8"W×1.95"H
Display Digit Height
0.56 "
Function
Voltage
Number Of Digits
3-1/2
Primary Type
Electronic
Range, Measurement
±25 VDC
Response Time
1 sec.
Temperature, Operating
0 to 60 °C
Voltage, Input
±25 VDC
Voltage, Supply
85 to 250 VAC
Weight
0.65 lbs.
Character Size
0.56"
Display Font Color
Red
Rohs Compliant
NA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
na, Contains lead / RoHS non-compliant
Other names
RLC113
1.
2. OVER-RANGE INDICATION: Indicated by blanking 3 least significant
3. POWER:
4. INPUT SENSITIVITY: (Numerical Readout Change/Volt) Adjustable from
5. INPUT RESISTANCE: 1 M Ω
6. SCALING RANGE:
7. LINEARITY: ±(0.05% ±1 digit)
8. READING RATE: 2.5 updated readings / second, nominal.
9. RESPONSE TIME: 1 second to settle for step change.
10. LOW FREQUENCY NOISE REJECTION:
11. ENVIRONMENTAL CONDITIONS:
12. CERTIFICATIONS AND COMPLIANCES:
G
DISPLAY: 3 1/2-digit, 0.56" (14.2 mm) high, 7-segment LED, (-) minus sign
displayed when current or voltage is negative. Decimal points inserted before
1st, 2nd, or 3rd least significant digits by DIP switch selection.
digits.
AC Power: 85 to 250 VAC, 50/60 HZ, 6 VA
Isolation: 2300 Vrms for 1 min. to all inputs.
40 units/volt to 1000 units/volt. Max. allowable input voltage, ±25 volts DC.
SPAN: 32 coarse steps (binary progression with 5 DIP switches) Each step
providing approx. 40 numerical units/volt/step sensitivity. Fine adjust
brackets the coarse step increments.
OFFSET: 16 coarse steps (binary progression with 4 DIP switches) with ±
switch to add or subtract offset. Each step adds or subtracts approximately
175 from the numerical display for a total offset range of ±2700. Fine control
brackets the steps.
Normal Mode Rejection: 63 dB @ 50/60 Hz
Common Mode Rejection: 100 dB, DC to 50/60 Hz
Operating Temperature: 0° to 60°C
Storage Temperature: -40° to 80°C
Operating and Storage Humidity: 85% max. relative humidity (non-
Span Temperature Coeff.: 100 PPM/°C
Offset Temperature Coeff.: 100 PPM/°C
Vibration According to IEC 68-2-6: Operational 5 to 150 Hz, in X, Y, Z
Shock According to IEC 68-2-27: Operational 30 g (10g relay), 11 msec in
Altitude: Up to 2000 meters
SAFETY
UL Recognized Component, File # E179259, UL61010A-1, CSA C22.2 No.
1010-1
UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95
condensing)
direction for 1.5 hours, 2g’s.
3 directions.
Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.
LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards
Type 4X Enclosure rating (Face only), UL50
ENERAL
M
ETER
S
PECIFICATIONS
13. EXCITATION SUPPLY: 24 VDC @ 50 mA max. Regulated and isolated.
14. CONNECTIONS: High compression cage-clamp terminal block
15. CONSTRUCTION: This unit is rated for NEMA 4X/IP65 indoor use. IP20
16. WEIGHT: 0.65 lbs (0.24 kg)
IECEE CB Scheme Test Certificate # US/8843A/UL
ELECTROMAGNETIC COMPATIBILITY
Emissions and Immunity to EN 61326: Electrical Equipment for
Measurement, Control and Laboratory use.
Notes:
Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 4.5 inch-lbs (0.51 N-m) max.
Touch safe. Installation Category II, Pollution Degree 2. One piece
bezel/case. Flame resistant. Panel Gasket and mounting clip included.
Immunity to Industrial Locations:
Electrostatic discharge
Electromagnetic RF fields
Fast transients (burst)
Surge
RF conducted interference
Power frequency magnetic fields
Voltage dip/interruptions
Emissions:
Emissions
CB Scheme Test Report # 04ME11209-20041018
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment
IP65 Enclosure rating (Face only), IEC 529
IP20 Enclosure rating (Rear of unit), IEC 529
1. Criterion A: Normal operation within specified limits.
2. Criterion B: Temporary loss of performance from which the unit self-
Issued by Underwriters Laboratories, Inc.
for measurement, control, and laboratory use, Part 1.
recovers.
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
EN 55011
Criterion A
4 kV contact discharge
8 kV air discharge
Criterion B
10 V/m
Criterion A
2 kV power
2 kV signal
Criterion A
1 kV L-L,
1 kV signal
Criterion A
3 V/rms
Criterion A
30 A/m
Criterion A
0.5 cycle
Class B
2 kV L&N-E power