Specifications of SP300

Measuring Range
200mVDC
Display Style
Red Characters, Black Background
Display Type
LED
Display Face Size
1.38" L x 0.88" W (35.1 x 22.4mm)
Display Digits
3.5
Display Digits - Height
0.370" (9.40mm)
Backlight
Red
Mounting Type
Panel Mount
Termination
PC Pins
Voltage - Supply
4.75 ~ 5.25V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
227-1052

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SP300-05S05N
Manufacturer:
MURATA
Quantity:
12 000
Part Number:
SP3001-04JTG
Manufacturer:
LITTEFUSE
Quantity:
20 000
Part Number:
SP3002-04HTG
Manufacturer:
SHARP
Quantity:
5 000
Part Number:
SP3002-04HTG
Manufacturer:
LITTEFUSE
Quantity:
20 000
Part Number:
SP3002-04JTG
Manufacturer:
LITTELFUSE/力特
Quantity:
20 000
Part Number:
SP3002-04JTG
0
Company:
Part Number:
SP3002-04UTG
Quantity:
1 961
Company:
Part Number:
SP3002-04UTG
Quantity:
1 813
Part Number:
SP3003-02JTG
Manufacturer:
LITTEFUSE
Quantity:
20 000
Part Number:
SP3003-02UTG
Manufacturer:
LITTELFUSE/力特
Quantity:
20 000
Part Number:
SP3003-04XTG
Manufacturer:
FREESCALE
Quantity:
60
Part Number:
SP3004-04XTG
Manufacturer:
Littelfuse Inc
Quantity:
34 210
Part Number:
SP300N
Manufacturer:
FUJ
Quantity:
1 055
Company:
Part Number:
SP300V4.0-E216-0
Quantity:
4 800
Company:
Part Number:
SP300V5.0-E106-0
Quantity:
4 800
SP 300
Specifications liable to change without prior warning
SCALING
Two resistors Ra and Rb
may be used to alter the
full scale reading (FSR) of
the meter - see table. The
meter will have to be re-
calibrated by adjusting the
calibration potentiometer
on the rear of the module.
APPLICATIONS
Do not connect more than one meter to the same power supply if the meters cannot use the same signal
ground. Taking any input beyond the power supply rails will damage the meter.
Measuring an input voltage referenced
to a floating supply, i.e. the input
voltage and the meter's power supply
are isolated from each other.
V
S selects between voltage and current measurement.
Ra and Rb shown scaled for 200V
Display DP1, DP2 or DP3, by connecting to 0V, as required.
supply
1
±200mV
+
-
4
5
3
IH
220nF
IL
COM
Measuring supply voltage and current to a load.
V+
0V
7805
1
2
V+
0V
+5V
10uF
470nF
FSR
3
COM
* Ensure that Ra is rated for high voltage use.
** Ensure solder link LA is cut.
Rs = 200mV
Voltage
Current
V+
0V
1
2
IH
IL
www.lascarelectronics.com
PO Box 770, Londonderry, NH 03053 1-800-821-0023
www.martelcorp.com
Measuring a single ended input
voltage referenced to supply, i.e. the
input voltage and the meter's power
supply share the same 0V rail.
4
5
I
S
FSR
1
V
A
2000V* 1M**
±200mV
200mA
(e.g. 0.1 / 400mW for 2A full scale)
200 A
20mA
200V
2mA
20V
FSR
Ra=1M
Rb=1k
2V
+
-
SP 300
Shunt
Rs
910k**
1M**
1M**
4
5
Load
Ra
0R
0R
0R
0R
IH
IL
I
V+
0V
1
2
Issue 3
R
L
100k
100R
100R
0V
10R
V+
10k
Rb
1k
1k
1R
October/2001
3½ Digit LED Voltmeter Module
current loop
Vin or in
4-20mA
R = 0.2
Measuring current.
The meter's supply is isolated
from the current being measured.
+
-
I
I
R
FSR
Measuring a 4-20mA loop current.
The meter's power supply must be
isolated from the 4-20mA current
loop.
I
I-
+
LA
Ra
R= Reading at 20mA
220k
M.C.
R
4
5
3
5k
Rb
IH
IL
COM
V+
0V
Set Zero
1
2
5
3
4
160
4
5
IL
COM
IH
IH
IL
Applies to SP 300/1
V+
0V
SP 300
V+
0V
1
2
Page 4 of 4
0V
V+
Page 4 of 4
Page 4 of 4