CY23FS08OXI Cypress Semiconductor Corp, CY23FS08OXI Datasheet - Page 8

no-image

CY23FS08OXI

Manufacturer Part Number
CY23FS08OXI
Description
IC CLK ZDB 8OUT 200MHZ 28SSOP
Manufacturer
Cypress Semiconductor Corp
Type
Fanout Distribution, Multiplexer , Zero Delay Bufferr
Series
Failsafe™r
Datasheet

Specifications of CY23FS08OXI

Number Of Circuits
1
Package / Case
28-SSOP
Pll
Yes with Bypass
Input
LVCMOS, LVTTL, Crystal
Output
LVCMOS
Ratio - Input:output
3:8
Differential - Input:output
No/No
Frequency - Max
166.7MHz
Divider/multiplier
No/No
Voltage - Supply
2.5V, 3.3V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Frequency-max
200MHz
Maximum Input Frequency
166.7 MHz
Minimum Input Frequency
1.04 MHz
Output Frequency Range
1.7 MHz to 166.7 MHz
Supply Voltage (max)
3.465 V
Supply Voltage (min)
3.135 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Operating Supply Voltage
3.3 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CY23FS08OXI-05
Manufacturer:
Cypress Semiconductor Corp
Quantity:
135
Document #: 38-07518 Rev. *C
Table 3. Pullability Range from XTAL with Different C0/C1
Ratio
Calculated value of the pullability range for the XTAL with
C0/C1 ratio of 200, 300 and 400 are shown in Table 3. For this
calculation Cl(min) = 8pF and Cl(max)= 32pF has been used.
Using a XTAL that has a nominal frequency specified at load
capacitance of 14pF, almost symmetrical pullability range has
been obtained.
Next, it is important to calculate the pullability range including
error tolerances. This would be the capture range of the input
reference frequency that the FailSafe device and XTAL combi-
nation would reliably span.
C0/C1 Ratio
200
300
400
Cload(min.)
8.0
8.0
8.0
Cload(max.)
32.0
32.0
32.0
Pullability
–385 333
–256 222
–192 166
Range
Calculating the capture range involves subtracting error
tolerances as follows:
Parameter ........................................................ f error (ppm)
Manufacturing frequency tolerance ...................................15
Temperature stability ..........................................................30
Aging ................................................................................... 3
Board/trace variation ........................................................... 5
Total ....................................................................................53
Example: Capture Range for XTAL with C0/C1 Ratio of 200
Negative Capture Range= –385 ppm + 53 ppm = –332 ppm
Positive Capture Range = 333 ppm – 53 ppm = +280 ppm
It is important to note that the XTAL with lower C0/C1 ratio has
wider pullability/capture range as compared to the higher
C0/C1 ratio. This will help the user in selecting the appropriate
XTAL for use in the FailSafe application.
CY23FS08
Page 8 of 12
[+] Feedback