ICS650R-07I IDT, Integrated Device Technology Inc, ICS650R-07I Datasheet - Page 5

no-image

ICS650R-07I

Manufacturer Part Number
ICS650R-07I
Description
IC NETWORKING CLK SOURCE 20-SSOP
Manufacturer
IDT, Integrated Device Technology Inc
Type
Clock/Frequency Synthesizerr
Datasheet

Specifications of ICS650R-07I

Pll
Yes with Bypass
Input
Clock, Crystal
Output
CMOS
Number Of Circuits
1
Ratio - Input:output
1:7
Differential - Input:output
No/No
Frequency - Max
133.33MHz
Divider/multiplier
Yes/No
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
20-SSOP
Frequency-max
133MHz
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
650R-07I

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICS650R-07ILFT
Manufacturer:
IDT
Quantity:
20 000
External Components
The ICS650-07C requires a minimum number of external
components for proper operation.
Decoupling Capacitor
Decoupling capacitors of 0.01µF must be connected
between each VDD and GND (pins 4 and 6, pins 16 and 14),
as close to the device as possible. For optimum device
performance, the decoupling capacitor should be mounted
on the component side of the PCB. Avoid the use of vias in
the decoupling circuit.
Series Termination Resistor
When the PCB trace between the clock outputs and the
loads are over 1 inch, series termination should be used. To
series terminate a 50 trace (a commonly used trace
Absolute Maximum Ratings
Recommended Operation Conditions
IDT™ / ICS™ NETWORKING CLOCK SOURCE
ICS650-07C
NETWORKING CLOCK SOURCE
Stresses above the ratings listed below can cause permanent damage to the ICS650-07C. These ratings, which are
standard values for IDT commercially rated parts, are stress ratings only. Functional operation of the device at these
or any other conditions above those indicated in the operational sections of the specifications is not implied.
Exposure to absolute maximum rating conditions for extended periods can affect product reliability. Electrical
parameters are guaranteed only over the recommended operating temperature range.
Supply Voltage, VDD
All Inputs and Outputs
Ambient Operating Temperature (commercial)
Ambient Operating Temperature (industrial)
Storage Temperature
Junction Temperature
Soldering Temperature (20 seconds max)
Parameter
Ambient Operating Temperature (commercial)
Ambient Operating Temperature (industrial)
Power Supply Voltage (measured with respect to GND)
Item
5
impedance) place a 33 resistor in series with the clock line,
as close to the clock output pin as possible. The nominal
impedance of the clock output is 20 .
Crystal Information
The crystal used should be a fundamental mode (do not use
third overtone), parallel resonant. Crystal capacitors should
be connected from pins X1 to ground and X2 to ground to
optimize the initial accuracy. The value of these capacitors
is given by the following equation:
In the equation, C
crystal with a 16 pF load capacitance, two 20 pF capacitors
should be used. If a clock input is used, drive it into X1 and
leave X2 unconnected.
Crystal caps (pF) = (C
Min.
+3.0
7 V
-0.5 V to VDD+0.5 V
0 to +70 C
-40 to +85 C
-65 to +150 C
125 C
260 C
-40
0
L
Typ.
+3.3
is the crystal load capacitance. So, for a
Rating
L
- 6) x 2
Max.
+5.5
+70
+85
CLOCK SYNTHESIZER
ICS650-07C
Units
V
C
C
REV D 102709

Related parts for ICS650R-07I