CY7B994V-5BBCT Cypress Semiconductor Corp, CY7B994V-5BBCT Datasheet - Page 12

IC CLK BUFF 18OUT 200MHZ 100LBGA

CY7B994V-5BBCT

Manufacturer Part Number
CY7B994V-5BBCT
Description
IC CLK BUFF 18OUT 200MHZ 100LBGA
Manufacturer
Cypress Semiconductor Corp
Type
Clock Buffer, Fanout Distributionr
Series
RoboClock™r
Datasheet

Specifications of CY7B994V-5BBCT

Number Of Circuits
1
Package / Case
100-LBGA
Pll
Yes
Input
LVPECL, LVTTL
Output
LVTTL
Ratio - Input:output
4:18
Differential - Input:output
No/No
Frequency - Max
200MHz
Divider/multiplier
Yes/Yes
Voltage - Supply
2.97 V ~ 3.63 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Frequency-max
200MHz
Maximum Input Frequency
200 MHz
Minimum Input Frequency
24 MHz
Output Frequency Range
24 MHz to 200 MHz
Supply Voltage (max)
3.63 V
Supply Voltage (min)
2.97 V
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Operating Supply Voltage
3.3 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CY7B994V-5BBCT
Manufacturer:
CYPRESS
Quantity:
213
Part Number:
CY7B994V-5BBCT
Manufacturer:
Cypress Semiconductor Corp
Quantity:
10 000
Switching Characteristics
Notes
Document #: 38-07127 Rev. *I
TTB
t
t
t
t
t
t
t
t
t
t
t
t
t
18. TTB is the window between the earliest and the latest output clocks with respect to the input reference clock across variations in output frequency, supply voltage,
19. Tested initially and after any design or process changes that may affect these parameters.
20. Rise and fall times are measured between 2.0V and 0.8V.
21. f
22. t
23. UI = Unit Interval. Examples: 1 UI is a full period. 0.1UI is 10% of period.
24. Measured at 0.5V deviation from starting voltage.
25. For t
26. These figures are for illustrations only. The actual ATE loads may vary.
Parameter
PDDELTA
REFpwh
REFpwl
r
LOCK
RELOCK1
RELOCK2
ODCV
PWH
PWL
PDEV
OAZ
OAZ
/t
f
operating temperature, input clock edge rate, and process. The measurements are taken with the AC test load specified and include output-output skew, cycle-cycle
jitter, and dynamic phase error. TTB is equal to or smaller than the maximum specified value at a given frequency.
NOM
PWH
OZA
must be within the frequency range defined by the same FS state.
is measured at 2.0V. t
minimum, C
Total Timing Budget window (same frequency and phase)
18]
Propagation Delay difference between two devices
REF input (Pulse Width HIGH)
REF input (Pulse Width LOW)
Output Rise/Fall Time
PLL Lock Time from Power up
PLL Relock Time (from same frequency, different phase)
with Stable Power Supply
PLL Relock Time (from different frequency, different phase)
with Stable Power Supply
Output duty cycle deviation from 50%
Output HIGH time deviation from 50%
Output LOW time deviation from 50%
Period deviation when changing from reference to
reference
DIS[1:4]/FBDIS HIGH to output high impedance from
ACTIVE
DIS[1:4]/FBDIS LOW to output ACTIVE from output high
impedance
For LOCK output only
R1 = 910
R2 = 910
C
L
< 30 pF
L
= 0 pF. For t
(Includes fixture and
probe capacitance)
[14, 24]
[23]
PWL
[24, 25]
is measured at 0.8V.
OZA
maximum, C
[20]
For all other outputs
R1 = 100
R2 = 100
C
Description
L
Over the Operating Range
[21]
< 25 pF to 185 MHz
GND
3.3V
Figure 5. AC Test Loads and Waveform
[19]
L
or 10 pF at 200 MHz
< 1 ns
[19]
= 25 pF to 185 MHz or 10 pF to 200 MHz.
(a) LVTTL AC Test Load
(b) TTL Input Test Waveform
[13]
[22]
[22]
0.8V
2.0V
OUTPUT
[9, 10, 11, 12, 13]
[17]
[17,
C
L
0.15
–1.0
Min
2.0
2.0
1.0
0.5
CY7B993/4V-2
3.3V
(continued)
Typ
2.0V
[26]
R1
R2
0.8V
< 1 ns
0.025
1000
Max
500
200
500
2.0
1.0
1.5
2.0
10
10
14
CY7B993V, CY7B994V
0.15
–1.0
Min
2.0
2.0
1.0
0.5
CY7B993/4V-5
Typ
RoboClock
0.025
1000
Max
700
200
500
2.0
1.0
1.5
2.0
10
10
14
Page 12 of 18
Unit
ms
s
s
ps
ps
ns
ns
ns
ns
ns
ns
UI
ns
ns
[+] Feedback

Related parts for CY7B994V-5BBCT