CY2X014FLXIT Cypress Semiconductor Corp, CY2X014FLXIT Datasheet - Page 5

IC OSC LVPECL HP/HF 6-LCC

CY2X014FLXIT

Manufacturer Part Number
CY2X014FLXIT
Description
IC OSC LVPECL HP/HF 6-LCC
Manufacturer
Cypress Semiconductor Corp
Type
Oscillator, Crystalr
Datasheets

Specifications of CY2X014FLXIT

Pll
Yes
Input
Crystal
Output
LVPECL
Number Of Circuits
1
Ratio - Input:output
1:1
Differential - Input:output
No/Yes
Frequency - Max
690MHz
Divider/multiplier
Yes/No
Voltage - Supply
2.375 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
6-CLCC
Frequency
690MHz
Operating Supply Voltage (typ)
2.5/3.3
Output Level
LVPECL
Symmetry Max
60%
Operating Temp Range
-40C to 85C
Screening Level
Industrial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
CY3675-LCC6A - BOARD ADAPTER LCC6A
Count
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
AC Electrical Characteristics
The following table lists the AC electrical specifications for this device.
Typical Output Characteristics
Document Number: 001-10179 Rev. *G
F
FSC
FSI
AG
T
T
T
T
T
T
Notes
OHZ
OE
4. Not 100% tested, guaranteed by design and characterization.
5. This parameter is specified in the CyClockWizard software
6. Frequency stability is the maximum variation in frequency from F
7. Typical phase noise specs for factory programmed devices are listed in the
OUT
DC
R
LOCK
Jitter(φ)
Parameter
, T
F
0.9
0.8
0.7
0.6
0.5
0.4
0
Output frequency
Frequency stability, commercial
devices
Frequency stability, industrial
devices
Aging, 10 years
Output duty cycle
Output rise and fall time
Output disable time
Output enable time
Startup time
RMS phase jitter (random)
100
Figure 2. 2.5-V Supply and Termination to V
[6]
[6]
200
Description
Frequency (MHz)
300
[5]
400
500
V
V
F > 450 MHz, measured at zero crossing
outputs (asynchronous)
a valid frequency (asynchronous)
measured from the time
V
F
Pre-defined factory configurations
F <= 450 MHz, measured at zero crossing
20% and 80% of full output swing
Time from falling edge on OE to stopped
Time from rising edge on OE to outputs at
Time for CLK to reach valid frequency
600
OUT
DD
DD
DD
0
= min to max, T
= min to max, T
= V
. It includes initial accuracy, and variation from temperature and supply voltage.
= 106.25 MHz (12 kHz to 20 MHz)
700
DD
(min.) or from PD# rising edge
Standard and Application-Specific Factory Configurations
Condition
DD
[4]
–1.5 V, Minimum V
A
A
= 0 °C to 70 °C
= –40 °C to 85 °C
1.40
1.35
1.30
1.25
1.20
0
100
[7]
DD
200
and Maximum T
Frequency (MHz)
300
Min
0.2
50
45
40
400
See Note 7
Typ
0.4
50
50
1
table on page 2.
500
A
Max
600
690
±35
±55
±15
100
100
CY2X014
1.0
55
60
10
Page 5 of 11
700
MHz
Unit
ppm
ppm
ppm
ms
ns
ns
ns
ps
ps
%
%
[+] Feedback

Related parts for CY2X014FLXIT