2-1761612-0 TE Connectivity, 2-1761612-0 Datasheet
2-1761612-0
Specifications of 2-1761612-0
Available stocks
Related parts for 2-1761612-0
2-1761612-0 Summary of contents
Page 1
... Qualification Test Results | Successful qualification testing on the subject product line was completed on 20Feb06. Additional | testing was completed on 12Jan07. The Qualification Test Report number for this testing is 501-627. This documentation is on file at and available from Engineering Practices and Standards (EPS). 2. APPLICABLE DOCUMENTS The following documents form a part of this specification to the extent specified herein ...
Page 2
... R 10 milliohms maximum. ...
Page 3
... Three shocks in each direction applied along 3 mutually perpendicular planes, 18 total shocks. EIA-364-9. Mate and unmate specimens for 25 cycles at a maximum rate of 500 cycles per hour. The first 13 cycles shall be performed prior to specific environmental test in the sequence. The remaining 12 cycles shall be performed after environmental test ...
Page 4
... Specimens shall be tested until 63.2% of the specimens (18 connectors) have failed or until 2670 cycles have been completed. EIA-364-31, Method III. Subject mated specimens to 50 cycles (500 hours) between 25 and 95% RH. Temperature / ramp shall be 1 hour per transition with 3 hour minimum dwell ...
Page 5
... Procedure EIA-364-65, Class IIA (4 gas). Subject mated and mounted specimens to environmental Class IIA for 20 days. After initial LLCR and 50% durability cycles, specimens shall be broken into 2 groups of 5. The plugs from the first group and the receptacles from the second group, shall be placed in the chamber unmated for 10 days ...
Page 6
... First half of the total number of specified cycles. (g) Second half of the total number of specified cycles. (h) After initial LLCR and 50% durability cycles, specimens shall be broken into 2 groups of 5. The plugs from the first group and the receptacles from the second group, shall be placed in the chamber unmated for 10 days ...
Page 7
... Specimens shall be prepared in accordance with applicable Instruction Sheets and shall be selected at random from current production per Figure 2. Test group 1 requires 10 connector pairs terminated to LLCR PCB. Test group 2 requires 5 connector pairs terminated to LLCR PCB and a minimum of 3 connector pairs terminated to continuity PCB. Test group 3 requires 3 loose piece connector pairs ...
Page 8
... Low Level Contact Resistance Measurement Points Rev B Figure 3 108-2143 ...