Specifications of DS1556W-120

Memory Size
1M (128K x 8)
Time Format
HH:MM:SS (24 hr)
Date Format
YY-MM-DD-dd
Interface
Parallel
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Through Hole
Package / Case
32-DIP Module (600 mil), 32-EDIP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS1556W-120
Manufacturer:
DALLAS
Quantity:
10
Part Number:
DS1556W-120
Quantity:
11
Part Number:
DS1556W-120+
Manufacturer:
Maxim Integrated Products
Quantity:
135
Part Number:
DS1556W-120+
Manufacturer:
STM
Quantity:
5 258
Part Number:
DS1556W-120IND
Manufacturer:
AD
Quantity:
1
CE,
USING THE CLOCK ALARM
The alarm settings and control for the DS1556 reside within Registers 1FFF2h to 1FFF5h. Register
1FFF6h contains two alarm enable bits: Alarm Enable (AE) and Alarm in Backup Enable (ABE). The AE
and ABE bits must be set as described below for the IRQ/FT output to be activated for a matched alarm
condition.
The alarm can be programmed to activate on a specific day of the month or repeat every day, hour,
minute, or second. It can also be programmed to go off while the DS1556 is in the battery-backed state of
operation to serve as a system wake-up. Alarm mask bits AM1 to AM4 control the alarm mode. Table 3
shows the possible settings. Configurations not listed in the table default to the once per second mode to
notify the user of an incorrect alarm setting.
Table 3. Alarm Mask Bits
When the RTC Register values match Alarm Register settings, the Alarm Flag bit (AF) is set to a 1. If
Alarm Flag Enable (AE) is also set to a 1, the alarm condition activates the IRQ/FT pin. The IRQ/FT
signal is cleared by a read or write to the Flags Register (Address 1FFF0h) as shown in Figure 2 and 3.
When CE is active, the IRQ/FT signal may be cleared by having the address stable for as short as 15 ns
and either OE or WE active, but is not guaranteed to be cleared unless t
also cleared by a read or write to the Flags Register but the flag will not change states until the end of the
read/write cycle and the IRQ/FT signal has been cleared.
Figure 2. Clearing IRQ Waveforms
AM4
1
1
1
1
0
0V
AM3
1
1
1
0
0
AM2
1
1
0
0
0
AM1
1
0
0
0
0
ALARM RATE
Once per second
When seconds match
When minutes and seconds match
When hours, minutes, and seconds match
When date, hours, minutes, and seconds match
8 of 18
DS1556 1M, Nonvolatile, Y2K-Compliant Timekeeping RAM
RC
is fulfilled. The alarm flag is