ADC0809CCN/NOPB National Semiconductor, ADC0809CCN/NOPB Datasheet - Page 9

no-image

ADC0809CCN/NOPB

Manufacturer Part Number
ADC0809CCN/NOPB
Description
IC ADC 8BIT MPU 8CH MUX 28-DIP
Manufacturer
National Semiconductor
Datasheet

Specifications of ADC0809CCN/NOPB

Number Of Bits
8
Number Of Converters
1
Power Dissipation (max)
875mW
Voltage Supply Source
Single Supply
Operating Temperature
-40°C ~ 85°C
Mounting Type
Through Hole
Package / Case
28-DIP (0.600", 15.24mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
*ADC0809CCN
*ADC0809CCN/NOPB
ADC0809
ADC0809CCN

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADC0809CCN/NOPB
Manufacturer:
TI
Quantity:
2 400
TRI-STATE Test Circuits and Timing Diagrams
Applications Information
OPERATION
1.0 RATIOMETRIC CONVERSION
The ADC0808, ADC0809 is designed as a complete Data
Acquisition System (DAS) for ratiometric conversion systems.
In ratiometric systems, the physical variable being measured
is expressed as a percentage of full-scale which is not nec-
essarily related to an absolute standard. The voltage input to
the ADC0808 is expressed by the equation
A good example of a ratiometric transducer is a potentiometer
used as a position sensor. The position of the wiper is directly
proportional to the output voltage which is a ratio of the full-
scale voltage across it. Since the data is represented as a
V
V
V
D
D
D
IN
fs
Z
X
MAX
MIN
= Zero voltage
= Full-scale voltage
= Data point being measured
= Input voltage into the ADC0808
= Minimum data limit
= Maximum data limit
t
t
1H
H1
, C
, C
t
1H
L
L
, t
= 10 pF
= 50 pF
H1
FIGURE 8. TRI-STATE Test Circuits and Timing Diagrams
567220
567218
567219
(1)
9
proportion of full-scale, reference requirements are greatly
reduced, eliminating a large source of error and cost for many
applications. A major advantage of the ADC0808, ADC0809
is that the input voltage range is equal to the supply range so
the transducers can be connected directly across the supply
and their outputs connected directly into the multiplexer in-
puts, (Figure 9).
Ratiometric transducers such as potentiometers, strain
gauges, thermistor bridges, pressure transducers, etc., are
suitable for measuring proportional relationships; however,
many types of measurements must be referred to an absolute
standard such as voltage or current. This means a system
reference must be used which relates the full-scale voltage to
the standard volt. For example, if V
full-scale range is divided into 256 standard steps. The small-
est standard step is 1 LSB which is then 20 mV.
2.0 RESISTOR LADDER LIMITATIONS
The voltages from the resistor ladder are compared to the
selected into 8 times in a conversion. These voltages are
coupled to the comparator via an analog switch tree which is
referenced to the supply. The voltages at the top, center and
bottom of the ladder must be controlled to maintain proper
operation.
The top of the ladder, Ref(+), should not be more positive than
the supply, and the bottom of the ladder, Ref(−), should not
be more negative than ground. The center of the ladder volt-
t
t
0H
H0
, C
, C
t
0H
L
L
, t
= 10 pF
= 50 pF
H0
CC
=V
REF
567223
567221
=5.12V, then the
567222
www.national.com

Related parts for ADC0809CCN/NOPB