AD9042ASTZ Analog Devices Inc, AD9042ASTZ Datasheet - Page 21

IC ADC 12BIT 41MSPS 44-TQFP

AD9042ASTZ

Manufacturer Part Number
AD9042ASTZ
Description
IC ADC 12BIT 41MSPS 44-TQFP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD9042ASTZ

Data Interface
Parallel
Number Of Bits
12
Sampling Rate (per Second)
41M
Number Of Converters
3
Power Dissipation (max)
735mW
Voltage Supply Source
Analog and Digital, Dual ±
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
44-TQFP, 44-VQFP
Resolution (bits)
12bit
Sampling Rate
41MSPS
Input Channel Type
Single Ended
Supply Voltage Range - Analog
5V
Supply Voltage Range - Digital
5V
Supply Current
119mA
Number Of Elements
1
Resolution
12Bit
Architecture
Pipelined
Sample Rate
41MSPS
Input Polarity
Unipolar
Input Type
Voltage
Rated Input Volt
1.9/2.9V
Differential Input
No
Power Supply Requirement
Single
Single Supply Voltage (typ)
5V
Single Supply Voltage (min)
4.75V
Single Supply Voltage (max)
5.25V
Dual Supply Voltage (typ)
Not RequiredV
Dual Supply Voltage (min)
Not RequiredV
Dual Supply Voltage (max)
Not RequiredV
Power Dissipation
735mW
Differential Linearity Error
±1LSB
Integral Nonlinearity Error
±0.75LSB(Typ)
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
44
Package Type
LQFP
Input Signal Type
Single-Ended
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD9042ASTZ
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
AD9042ASTZ
Manufacturer:
ADI
Quantity:
205
Part Number:
AD9042ASTZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
RECEIVE CHAIN FOR DIGITAL AND ANALOG BEAM FORMING MEDICAL ULTRASOUND USING
THE AD9042
The AD9042 is an excellent digitizer for digital and analog beam-
forming medical ultrasound systems. The price/performance ratio
of the AD9042 allows ultrasound designers the luxury of using
state-of-the-art ADCs without jeopardizing their cost budgets.
ADC performance is critical for image quality. The high dynamic
range and excellent noise performance of the AD9042 enable
higher image quality medical ultrasound systems.
Figure 45 shows the AD9042 used in one channel of the receive
chain of a medical ultrasound system. The
input directly from the transducer or from an external preamp
connected to the transducer. The AD604 contains two separate
stages. The first stage is a preamp with a fixed gain (14 dB to
20 dB) selected by a fixed resistor. The second stage is a variable
gain amplifier with the gain set by the
is increased over time to compensate for the attenuation of
signal level in the body.
AD7226
AD604
DAC. The gain
receives its
Rev. B | Page 21 of 24
Following the AD604, a low-pass filter is used to minimize the
amount of noise presented to the ADC. The
buffer the filter from the AD9042 input. This function may not
be required depending on the filter configuration and PCB
partitioning. The digital outputs of the AD9042 are then presented
to the digital system for processing.
TRANSDUCER/
PRE-AMP
INPUT
Figure 45. Using the AD9042 in Ultrasound Applications
+14dB TO +20dB
PRE-AMP
AD7226
AD604
–14dB TO +34dB
VGA
LPF
AD8041
AD8041
AD9042
is used to
AD9042

Related parts for AD9042ASTZ