6-644511-7 TE Connectivity, 6-644511-7 Datasheet
6-644511-7
Specifications of 6-644511-7
Related parts for 6-644511-7
6-644511-7 Summary of contents
Page 1
... The standard system is available in 2 through 28 positions. The MTA-100 connector system is designed to be terminated to 28 AWG to 22 AWG wire, tin plated UL style 1007, 1061 or wire which specifies PVC insulation with temperature rating compatible with specified operating temperatures, see Figure 4. Wire shall meet application requirements specified in Application Specification 114-1019 ...
Page 2
... Termination tensile strength, perpendicular, unmated. Rev H Requirement Meets requirements of product drawing and Application Spec 114- 1019. ELECTRICAL 6 milliohms maximum initial. ∆R 10 milliohms maximum. 5000 megohms minimum initial. 750 vac at sea level. 1 minute hold with no breakdown or flashover. 30° C maximum temperatur e rise at specified current. ...
Page 3
... See Note. See Note. Figure 1 (end) 108-1050 Procedure TE Spec 109-21-1. Subject mated samples to 10-55-10 Hz traversed in 1 minute at .06 inch total excursion. 2 hours in each of 3 mutually perpendicular planes. TE Spec 109-26-1. Subject mated samples to 50 G's half-sine shock pulses of 11 milliseconds duration. 3 shocks in ...
Page 4
... Subject half the samples to the parallel tensile test and the remaining half to the perpendicular tensile test. (g) Precondition samples with 5 cycles durability. Rev H Test Group (a) 1 2(c) 3( Test Sequence (b) 1,9 1,9 1,5 1,8 1,3 3,7 2,7 2,4 2,6 3,7 3,8 2( level for 100% loadings per Figure 2 108-1050 6 1 ...
Page 5
... PN 93-660017. Test group 4 shall consist of 5 unmounted 24 position standard tin-lead plated samples terminated to the maximum wire size. Test group 5 shall consist position standard tin-lead plated samples terminated to 28 AWG wire position standard tin-lead plated samples terminated to 24 AWG wire; and 6, 10 position standard tin-lead plated samples terminated to 22 AWG wire ...
Page 6
... Termination resistance equals millivolts divided by test current less resistance of 2 NOTE inches of wire. (b) After wave soldering, the boards and posts shall be cleaned to remove all flux and contaminates. Temperature & Termination Resistance Measurement Points Rev H Figure 3 108-1050 ...
Page 7
... NOTE gage indicated, use the Multiplication Factor (F) from the above chart and multiply it times the Base Rated Current for a single circuit at maximum ambient operating temperature as shown in Figure 4A. Rev H Figure 4A Current Carrying Capability Wire Size AWG 100 .3 .4 Figure 4B Current Rating 108-1050 1 ...
Page 8
PC Board Used For Termination Resistance Dry Circuit Rev H PC Board Used For Current Rating Figure 5 Printed Circuit Test Boards 108-1050 ...
Page 9
... Rev H Figure 6 Termination Tensile Strength 108-1050 ...