7-1877847-2 TE Connectivity, 7-1877847-2 Datasheet
7-1877847-2
Specifications of 7-1877847-2
Related parts for 7-1877847-2
7-1877847-2 Summary of contents
Page 1
... All inspections shall be perform ed using the applicable inspection plan and product drawing. 1.3. Qualification Test Results Successful qualification testing on the subject product line was com pleted on 16Apr07. The Qualification Test Report num ber for this testing is 501-655. This docum entation is on file at and available from Engineering Practices and Standards (EPS). ...
Page 2
... Current: Signal application only. Current per individual m ated contact pair in free air shown in Figure 1. ! Tem perature: -50 to 170°C 3.4. Perform ance and Test Description Product is designed to m eet the electrical, m echanical and environm ental perform ance requirem ents specified in Figure 2. Unless otherwise specified, all tests shall be perform bient environm ental conditions per EIA-364 ...
Page 3
... EIA-364-13. Measure force necessary to unm ate specim ens axim um rate of 12 [0.5 in] per m inute. EIA-364-32. Subject m ated specim ens to 5 cycles between -50 and 170°C. EIA-364-31, Method III. Subject m ated specim ens to 10 cycles (10 days) between 25 and 65° ...
Page 4
... Numbers indicate sequence in which tests are performed. (d) Precondition specimens with 10 durability cycles. Rev B Requirem ent See Note. Figure 2 (end) Test Group ( Test Sequence ( 3,7 2,4 2 3(d) 3( Figure 3 108-2249 Procedure EIA-364-65, Class IIA (4 gas). Subject m ated specim ens to environm ental Class IIA for 20 days 2,6 3 ...
Page 5
QUALITY ASSURANCE PROVISIONS 4.1. Qualification Testing A. Specim en Selection Specim ens shall be prepared in accordance with applicable Instruction Sheets and shall be selected at random from current production. Each test group shall consist inim ...