7-215464-6 TE Connectivity, 7-215464-6 Datasheet
7-215464-6
Specifications of 7-215464-6
Related parts for 7-215464-6
7-215464-6 Summary of contents
Page 1
... It may not be disclosed to anyone, other than Tyco Tyco Electronics Electronics personnel, without written authorization from Tyco Electronics Corporation, Harisburg, Pennsylvania USA *Trademark R6-76 (Rev. 07-01) DATE 28/10 /98 APVD M.Gosselink This specification is a controlled document and subject to change. Contact the Engineering Control Organization for the latest revision ...
Page 2
... Products shall be of design, construction and physical dimensions as specified on the applicable product drawings. All connector types of the Micro-MaTch Miniature connector System are available from positions (only even numbers ) Centerline distance between contacts is 1,27 mm (0,50” multiple of this case of selectively loaded connectors, which are available for all versions. 3.2 Material and Finish: Contacts: Phosphor Bronze according DIN specifications, tinplated over nickel underlayer ...
Page 3
... Wire-to-board and/or Board-to-board connections with the connector system positioned on the solder side of the PC board -for instance Surface Mount Application- • Permanent connections of ribbon cable to PC board, using the Paddle board connector version. • Wire-to board connection with discrete wires. Rev. F R6-77 (Rev. 07-01) 108-19052 Page ...
Page 4
... COSI- cable specification The Micro-MaTch COSI connector is designed for untwisted discrete wires in the range from 20-28 AWG. - Maximum insulation diameter for wires between 20-24 AWG is ∅ 0. Maximum insulation diamter for wires between 24-28 AWG is ∅ 1.27 mm 3.6 Performance and Test description Ratings: − ...
Page 5
... SMC Female Top Entry with Male On Wire A valid for Female Side Entry with Male On Wire SMD Female Top Entry with Male On Wire Paddle board Crimp on Snap In Rev. F R6-77 (Rev. 07-01 Ambient Temperature (°C) Female Top Entry with Male On Board B valid ...
Page 6
... Para 2.4.2. ( Reflow soldering method ) In acc. with: Tyco Test Spec 109-201 Reflow curve § 3.4.B.2. Procedures In acc. with IEC 512-2 test 3a. In acc. with IEC 512-2 test 4a. In acc. with IEC 512-2 test 2a. Under dry circuit conditions. All contacts measured. ...
Page 7
... In acc. With IEC 912 test 2a Under dry circuit conditions All contacts measured. In acc. With IEC 512-2 test 2a Under dry circuit conditions All contacts measured. Procedures In acc. with IEC 512-8 test 5b. (COSI: 512-8 test15a) Contact retention in housing female connector In acc. with IEC 512-5 test 9a. Page ...
Page 8
... Performance Requirements or Severity 25/ 55°C 12/12 hours. unmated total 6 cycles. Temp. 70°C, test current 125 % of rated current (par 3.6.) 500 cycles. 45 min ON/15 min OFF. Temperature 105°C Duration: 16 hours. Temperature ° Duration 2 hrs, unmated -40/+105° ...
Page 9
... Rapid change of temperature 4. Axial strength of wire termination (rest of the lot) Testgroup 7: 1. Visual examination 2. Contact retention in housing Rev. F R6-77 (Rev. 07-01) Measurements Termination resistance Termination resistance Termination resistance Termination resistance Termination resistance Termination resistance Termination resistance Termination resistance Termination strength in Newtons ...
Page 10
... Visual examination Testgroup 3: 1. Visual examination 2. 3. Rapid change of temperature 4. 5. Visual examination Rev. F R6-77 (Rev. 07-01) Measurements Termination resistance Termination resistance Insulation resistance Insulation resistance Insulation resistance Measurements Termination resistance Termination resistance Termination resistance Termination resistance Termination resistance Termination resistance ...
Page 11
... Visual examination Testgroup 5: 1. Visual examination 2. Axial tensile strength of wire termination 3. Visual examination Rev. F R6-77 (Rev. 07-01) Termination resistance Termination resistance Push out forces in Newtons Measurements Termination resistance Termination resistance Termination resistance Termination resistance Termination resistance Termination resistance Termination strength in Newtons 108-19052 3 ...
Page 12
... Testgroup 3: 1. Visual examination 2. 3. Rapid change of temperature 4. 5. Vibration 6. 7. Visual examination Rev. F R6-77 (Rev. 07-01) Measurements Push-in force in Newtons Push-out forces in Newtons Termination resistance Termination resistance Measurements Termination resistance Insulation resistance Termination resistance Insulation resistance Termination resistance Insulation resistance ...
Page 13
... Rapid change of temperature 4. 5. Vibration 6. Visual examination Testgroup 4: 1. Visual examination 2. Contact retention in housing Rev. F R6-77 (Rev. 07-01) Measurements Push out force in Newtons Measurements Termination resistance Termination resistance Termination resistance Termination resistance Termination resistance Termination resistance Termination resistance Termination resistance 108-19052 Paragraph 3 ...
Page 14
... Climatic sequence a) Dry heat b) Damp heat cyclic, first cycle c) Cold d) Damp Heat cyclic, remaining 5 cycles 5. 6. Voltage proof 7. Visual examination 4. Rev. F R6-77 (Rev. 07-01) Measurements Insulation resistance Insulation resistance 108-19052 Paragraph 3.6.1 3.6.1 3.6.22 3.6.1 3.6.1 3.6.6 3.6.7 3.6.23 3.6.21 3.6.24 3 ...
Page 15
... At least 5 connectors of the 6 positions or at least 30 contacts shall be used for each testgroup. 4.1.2 Test sequence Qualification inspection shall be verified by testing samples as specified in spec. 108-19052 Par 3.7. 4.2 Requalification testing If changes significantly affecting form, fit or function are made to the product or the manufacturing process, product assurance shall co-ordinate requalification testing, consisting of all or part of the original testing sequence as determined by development/product, quality and reliability engineering ...