Specifications of 804-1260

Battery Charger Type
Switch Mode
Battery Technologies Supported
Lead Acid
Supply Voltage
265VAC
Charge Current Max
60A
© 2010 Xantrex Technology Inc. All rights reserved. Xantrex and TRUE CHARGE are trademarks of Schneider Electric Services International sprl, registered in the U.S. and other countries.
1
2
Note: Specifications subject to change without notice.
Three-Stage Charging
Multistage charging ensures batteries receive optimum charging, but with minimal wear and tear, regulating the voltage and current delivered
to the batteries in three automatic stages:
Power Factor Corrected (PFC)
Less shorepower is required for charging batteries, freeing up more usable AC power for running electrical devices and appliances and reducing
the likelihood of tripping shorepower breakers.
90 - 104 Vac ± 4 Vac output de-rated to 80% of full load current
For 20A and 40A charger, output current derates above 50°C. For 60 A charger, output current derates above 40°C. Highly Accelerated Life Tested (HALT) to -20°C.
Bulk: Replaces 70-80% of the battery’s state-of-charge at the fastest possible rate.
Absorption: Replenishes the remaining 20-30% of charge, bringing the battery to a full charge at a slow, safe rate.
Float: Voltage is reduced and held constant in order to prevent damage and maintain batteries at a full charge.
20, 40 and 60 amp 12-volt Multistage Battery Chargers
Electrical Specifications
Models
Output current (nominal)
Output voltage (nominal, depending on settings)
DC output connections
AC input voltage
Temperature compensation
Charger efficiency
Battery type
Minimum recommended battery bank size
General Specifications
Models
Operating temperature
Storage temperature
Battery connection
Dimensions (H x W x L)
Weight
Warranty
Part Numbers
Accessories
Remote panel
Remote panel
Battery temperature sensor
Regulatory Compliance
CSA E60335-2-29, UL1564, and UL1236 including the Marine Supplement and drip test. CE Marked for the Low Voltage Directive (safety) and the EMC Directive.
Complies with IEC 60335-2-29 including Australian deviations. Ingress protection rating IP32 per EN/IEC 60529. Complies with FCC Part 15B and Industry Canada
ICES-003 Class B emissions limits. Complies with ABYC A-31
· Charge
· Float
· Equalize
1
2
(@ 25°C unless otherwise noted)
TRUECHARGE2 20 / 40
20 A / 40 A
14.2 - 15.5 Vdc
13.4 - 13.8 Vdc
16 Vdc
Three
90-265 Vac 47-63 Hz
120 Vac, 230 Vac, 240 Vac nominal
> 80%
Gel, Flooded, AGM and Pb-Ca
40 Ah for 20 A / 80 Ah for 40 A
TRUECHARGE2 20 / 40
0 to 65°C
-40 to 80°C
Three positive terminals
One negative terminal
2.8 x 6.7 x 9.8” (70 × 170 × 250mm)
4.8 lb (2.2 kg)
Two year
804-1220-02 / 804-1240-02
808-8040-00 (60 A charger)
808-8040-01 (20 A and 40 A charger)
808-0232-01
Three settings or optional remote battery temperature sensor
TRUECHARGE2 60
60 A
14.2 - 15.5 Vdc
13.4 - 13.8 Vdc
16 Vdc
Three
90-265 Vac 47-63 Hz
120 Vac, 230 Vac, 240 Vac nominal
> 80%
Gel, Flooded, AGM and Pb-Ca
120 Ah for 60 A
TRUECHARGE2 60
0 to 65°C
-40 to 80°C
Three positive terminals
One negative terminal
3.5 x 6.7 x 13.4” (90 x 170 x 340 mm)
9.9 lb (4.5 kg)
Two year
804-1260