830611-8 TE Connectivity, 830611-8 Datasheet - Page 2

LGH 1/2 SGL END MOLDED LEAD

830611-8

Manufacturer Part Number
830611-8
Description
LGH 1/2 SGL END MOLDED LEAD
Manufacturer
TE Connectivity
Datasheets

Specifications of 830611-8

Product Type
Lead Assembly
Mount Angle
Straight
Cap Material
Glass-Filled Polyester
Wire Size (mm² [awg])
16
Operating Voltage (kvdc)
10
Shielded
No
Lead Assembly Type
Single-End
Assembly Length (mm [in])
101.60 [4.003]
Barrel Depth (mm [in])
13.50 [0.530]
Positive Stop Ferrule
Without
Wire Color
White (Standard)
Cap Color
Green
Pigtail Length (mm [in])
9.65 [0.380]
Wire Diameter (mm [in])
4.22 [0.166]
Wire Insulation
Silicone
Preloaded
Yes
Barrel Diameter (mm [in])
3.96 [0.156]
Rohs/elv Compliance
Not reviewed for ELV/RoHS compliance
Lead Free Solder Processes
Not reviewed for lead free solder process
3.2.
3.3.
3.4.
3.5.
Rev O2
Initial exam ination of product.
Final exam ination of product.
Contact resistance.
Insulation resistance.
W ithstanding voltage.
Materials
Materials used in the construction of this product shall be as specified on the applicable product
drawing.
Ratings
!
!
Perform ance and Test Description
Product is designed to m eet the electrical, m echanical and environm ental perform ance requirem ents
specified in Figure 1. Unless otherwise specified, all tests shall be perform ed at am bient environm ental
conditions per EIA-364.
Test Requirem ents and Procedures Sum m ary
Test Description
Voltage:
Tem perature:
1/2I:
1/2LI:
1I:
1LI:
2I:
3I:
4I:
15 kilovolts
-55 to 125 C
10 kilovolts
20 kilovolts
25 kilovolts
30 kilovolts
40 kilovolts
50 kilovolts
Meets requirem ents of product
drawing.
Meets visual requirem ents.
100 m illiohm s m axim um .
5000 m egohm s m inim um .
5 m icroam peres m axim um leakage
current. 3 m inute hold.
Series
1/2LI
1/2I
1LI
1I
2I
3I
4I
Figure 1 (cont)
ELECTRICAL
Requirem ent
Test Voltage
(kvDC)
15
23
30
38
45
55
60
EIA-364-18.
EIA-364-21.
EIA-364-18.
Visual and dim ensional (C of C)
inspection per product drawing.
Visual inspection.
EIA-364-6.
Measure potential drop of m ated
specim ens at 1 am pere m axim um .
Calculate resistance.
See Figure 3.
Test between contacts of m ated
lead connector assem blies and
ground.
EIA-364-20, Condition I.
Test between contacts of m ated
lead connector assem blies and
ground.
Procedure
108-36033
2 of 6