Specifications of MAX5457EEE+

Taps
32
Resistance (ohms)
10K
Number Of Circuits
2
Temperature Coefficient
50 ppm/°C Typical
Memory Type
Volatile
Interface
Pushbutton
Voltage - Supply
±2.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
16-QSOP
Resistance In Ohms
10K
Number Of Pots
Dual
Taps Per Pot
32
Resistance
10 KOhms
Wiper Memory
Volatile
Digital Interface
Debounced Pushbutton Up+ Down
Operating Supply Voltage
3.3 V, 5 V
Supply Current
100 uA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.7 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
In balance-control mode, the MAX5456/MAX5457
adjust the balance between channel 0 and channel 1
while maintaining the set volume. For example, if the
volume of channel 0 equals the volume of channel 1,
forcing the balance towards channel 1 increases the
attenuation of channel 0 (Figure 4a). If channel 1 is at a
higher attenuation than channel 0, adjusting the bal-
ance to channel 1 moves channel 1’s wiper up to the
same wiper position as channel 0 before attenuating
channel 0 (Figure 4b).
To control the wiper quickly with a logic signal, main-
tain pulses at least 22.5ms wide and separated by at
least 40ms.
Figure 4. Balance-Control Operation
H_
H_
L_
L_
(a)
(b)
_______________________________________________________________________________________
VOLUME LEVEL IS SET BY W0
W0
W0
VOLUME LEVEL IS SET
Stereo Audio Taper Potentiometers
W1
W1
Balance Control
PRESS BAL1
PRESS BAL1
ONCE
ONCE
with Pushbutton Interface
W0
W0
Table 2. Wiper Action vs. Pushbutton
Contact Duration
CONTACT DURATION
22.5ms < t ≤ 1s
t < 22.5ms
1s < t ≤ 4s
W1
t > 4s
W1
PRESS BAL1
PRESS BAL1
ONCE
ONCE
No motion (debouncing).
Wiper changes position once.
Wiper changes position
at a rate of 4Hz.
Wiper changes position
at a rate of 16Hz.
VOLUME LEVEL MAINTAINED
VOLUME LEVEL MAINTAINED
W0
W0
BALANCE SHIFTS TO W1